Dell Technologies Solutions for Microsoft Azure
Dell Integrated System for Microsoft Azure Stack Hub
This hybrid cloud platform delivers infrastructure and platform as a service (IaaS and PaaS) with a consistent Azure experience on-premises and in the public cloud.
Access, create, and share application services securely across Azure and Azure Stack for both traditional and cloud-native applications.
Get hyper-converged infrastructure, networking, backup, and encryption from Dell Technologies, with application development tools from Microsoft.
It delivers enterprise-grade performance and resiliency, including integrated deployment services from Dell Technologies experts.
One-contact support reduces your operational risk, while flexible consumption models make it easy to use.
Dell AX System for Azure Local
A purpose-built system designed to simplify and streamline Azure multi-cloud ecosystem with integrated fully engineered infrastructure foundation.
Designed with full-stack lifecycle management and native Azure integration, the integrated system delivers efficient operations, flexible consumption models and high-level enterprise expertise.
1 - Azure Stack Hub
Dell Integrated System for Microsoft Azure Stack Hub
Run your own private, autonomous cloud — connected or disconnected with cloud-native apps using consistent Azure services on-premises.
Run connected or disconnected from the public cloud
Comply with data sovereignty laws and regulations
Run Azure-consistent Infrastructure-as-a-Service (IaaS) and Platform-as-a-Service (PaaS)
Build cloud-native modern apps
1.1 - Release Artifacts
1.1.1 - Release Artifacts for Dell 2603
1.1.1.1 - Release Artifacts for 16G - Dell 2603
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2603.10_OEMPackage.zip 2603.10
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2601_Dell2603.6.iso 2603.6
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2603.2_LifecycleManager.zip 2603.2
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2601.0.4 Azure Stack Hub 2601 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2601.0.4 N/A
Hardware Lifecycle Host ISO 2603.6 N/A
Microsoft Partner Toolkit (PTK) 1.2601.3322.143 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5078766 See the Windows support document KB5078766 .
OS10 switch firmware (S5248) 10.6.1.0 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2603.10 Contains the driver and firmware update payload.
OEM package 2603.10 Includes the OEM extension package.
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BIOS Firmware DUP BIOS N/A 8NHX5 457WM 2.8.1 2.9.4
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A CPLD Firmware DUP CPLD N/A 503F0 XJG0V 1.2.6 1.2.7
Scale Units (PowerEdge R760) R760
Scale Units (PowerEdge R760) R760 N/A HBA355i Firmware DUP Storage - HBA K6MCJ Y99R5 CG0P9 24.15.14.00 33.15.00.00
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A NK22D 924YT 7.20.60.50 7.30.10.50
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 WS2022 Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 PWYXM FWT33 25.07 25.10.51000
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 K65HP XG5FJ 26.44.10.36 26.47.10.88
Scale Units (PowerEdge R760) R760
N/A 16G N/A S5248F-ON Switch Firmware TOR N/A 214KP 8N9K7 10.6.0.6 10.6.1.0
1.1.2 - Release Artifacts for Dell 2511
1.1.2.1 - Release Artifacts for 14G - Dell 2511
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2511.6.zip 2511.6
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2511.1.zip 2.4.2511.1
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2511.12_Redeployment.zip 2511.12
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2511.14.exe 2.0.2511.14
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2511.4 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2511.15 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2511.14 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2511.10 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2511.6 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5068787 See the Windows support document KB5068787 .
OS10 switch firmware (S5248, N3248) 10.6.0.6 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2511.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.4.2504.1 N/A
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Hardware Lifecycle Host/HLH (PowerEdge R640) R640 N/A BIOS Firmware DUP BIOS N/A T4VCN 9M80P 2.24.0 2.25.0
Scale Units (PowerEdge R640 AS All Flash) R640
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840 N/A BIOS Firmware DUP BIOS N/A NW297 V76F2 2.24.0 2.25.0
Hardware Lifecycle Host/HLH (PowerEdge R640) R640 N/A iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR VP556 7.00.00.181 7.00.00.183
Scale Units (PowerEdge R640 AS All Flash) R640
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
Scale Units (PowerEdge R640 AS All Flash) R640 WS2022 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A 3G71F PWYXM 25.1 25.07
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
N/A 14G N/A S5248F-ON Switch Firmware TOR N/A P8GNV 214KP 10.6.0.5 10.6.0.6
N/A 14G N/A N3248TE-ON Switch Firmware BMC N/A P8GNV 214KP 10.6.0.5 10.6.0.6
1.1.2.2 - Release Artifacts for 16G - Dell 2511
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2511.2_OEMPackage.zip 2511.2
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2506_Dell2511.3.iso 2511.3
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2511.5_LifecycleManager.zip 2511.5
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2511.3 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5068787 See the Windows support document KB5068787 .
OS10 switch firmware (S5248) 10.6.0.6 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2511.2 Contains the driver and firmware update payload.
OEM package 2511.2 Includes the OEM extension package.
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BIOS Firmware DUP BIOS N/A 2GWNP 8NHX5 2.7.4 2.8.1
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 58MWX 7.1 7.20
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM K65HP 26.41.1000 26.44.10.36
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 WS2022 Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 3G71F PWYXM 25.1 25.07
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A PERC H355 Adapter Firmware DUP Storage - HBA VCV6T PXRX0 1DHXW 52.30.0-6115 52.30.0-6347
N/A 16G N/A S5248F-ON Switch Firmware TOR N/A P8GNV 214KP 10.6.0.5 10.6.0.6
1.1.3 - Release Artifacts for Dell 2508
1.1.3.1 - Release Artifacts for 14G - Dell 2508
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2508.6.zip 2508.6
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2508.2.zip 2.4.2508.2
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2508.7_Redeployment.zip 2508.7
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2508.1.exe 2.0.2508.1
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2508.7 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2508.6 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5063880 See the Windows support document KB5063880 .
OS10 switch firmware (S5248, N3248) 10.6.0.5 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2508.2 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.4.2504.1 N/A
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Scale Units (PowerEdge R640 AS All Flash) R640 WS2022 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 3G71F 24.04.03 25.1
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
N/A 14G N/A S5248F-ON Switch Firmware TOR N/A 82WVT P8GNV 10.6.0.3 10.6.0.5
N/A 14G N/A N3248TE-ON Switch Firmware BMC N/A 82WVT P8GNV 10.6.0.3 10.6.0.5
1.1.3.2 - Release Artifacts for 16G - Dell 2508
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2508.4_OEMPackage.zip 2508.4
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2506_Dell2508.9.iso 2508.9
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2508.3_LifecycleManager.zip 2508.3
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2508.9 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248) 10.6.0.5 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2508.4 Contains the driver and firmware update payload.
OEM package 2508.4 Includes the OEM extension package.
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BIOS Firmware DUP BIOS N/A XK9CT W23G7 2.6.3 2.7.5
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BOSS-N1 Firmware DUP BOSS-N1 2MFVD 33TD2 C6MVR 2.1.13.2033 2.1.13.2037
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A WN31M 6CKFT 7.20.30.50 7.20.60.50
Scale Units (PowerEdge R760) R760
N/A 16G N/A S5248F-ON Switch Firmware TOR N/A 82WVT P8GNV 10.6.0.3 10.6.0.5
1.1.4 - Release Artifacts for Dell 2504
1.1.4.1 - Release Artifacts for 14G - Dell 2504
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2504.7.zip 2504.7
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2504.1.zip 2.4.2504.1
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2504.5_Redeployment.zip 2504.5
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2504.2.exe 2.0.2504.2
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2406.0.8 N/A
Hardware Lifecycle Host ISO 2504.2 N/A
Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2504.50 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2504.2 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2504.8 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2504.7 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248, N3248) 10.6.0.3 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2504.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.2.2204.1 N/A
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Scale Units (PowerEdge R840 AS Dense) R840 N/A BIOS Firmware DUP BIOS N/A 5T6CY NW297 2.22.1 2.24.0
Hardware Lifecycle Host/HLH (PowerEdge R640) R640 N/A BIOS Firmware DUP BIOS N/A F8GPH T4VCN 2.22.2 2.24.0
Scale Units (PowerEdge R640 AS All Flash) R640
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Hardware Lifecycle Host/HLH (PowerEdge R640) R640 N/A iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG RVDDR 7.00.00.174 7.00.00.181
Scale Units (PowerEdge R640 AS All Flash) R640
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
Scale Units (PowerEdge R640 AS All Flash) R640 N/A INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840 N/A INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R840 AS Dense) R840 N/A INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 AS All Flash) R640 N/A INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R640 AS All Flash) R640 N/A INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
Scale Units (PowerEdge R640 AS All Flash) R640 N/A INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
Scale Units (PowerEdge R640 AS All Flash) R640 N/A INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH 9RF8X VJPKG DL7A DL7C
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
Scale Units (PowerEdge R640 AS All Flash) R640 N/A Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A PY7FC 76DNG 14.32.20.04 14.32.21.02
Scale Units (PowerEdge R640 Tactical) R640
Scale Units (PowerEdge R740xd) R740xd
Scale Units (PowerEdge R840 AS Dense) R840
N/A 14G N/A S5248F-ON Switch Firmware TOR N/A HD1V8 82WVT 10.6.0.1 10.6.0.3
N/A 14G N/A N3248TE-ON Switch Firmware BMC N/A HD1V8 82WVT 10.6.0.1 10.6.0.3
1.1.4.2 - Release Artifacts for 16G - Dell 2504
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2504.2_OEMPackage.zip 2504.2
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2406_Dell2504.6.iso 2504.6
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2504.2_LifecycleManager.zip 2504.2
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2406.0.8 N/A
Hardware Lifecycle Host ISO 2504.6 N/A
Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248) 10.6.0.3 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2504.2 Contains the driver and firmware update payload.
OEM package 2504.2 Includes the OEM extension package.
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BIOS Firmware DUP BIOS N/A K77XK XK9CT 2.5.4 2.6.3
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 5MXXN WN31M 7.20.10.50 7.20.30.50
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 WS2022 Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 G6M58 3G71F 24.04.03 25.1
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A WR74F R39FM 3.32 3.33
Scale Units (PowerEdge R760) R760
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 WS2022 PERC H355 Adapter Driver DUP Storage - HBA VCV6T WC00M 6R1TD 7.726.01.0 7.730.02.00
Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A PERC H355 Adapter Firmware DUP Storage - HBA VCV6T RRR7N PXRX0 52.26.0-5179 52.30.0-6115
N/A 16G N/A S5248F-ON Switch Firmware TOR N/A HD1V8 82WVT 10.6.0.1 10.6.0.3
1.1.5 - Release Artifacts for Dell 2502
1.1.5.1 - Release Artifacts for 14G - Dell 2502
Component File Name Supported Version Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2502.5.zip 2502.5 Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2502.1.zip 2.4.2502.1 Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2502.9_Redeployment.zip 2502.9 Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2502.16.exe 2.0.2502.16
Software Versions
Component Version Notes Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal. Hardware Lifecycle Host 1.2406.0.8 N/A Hardware Lifecycle Host ISO 2502.12 N/A Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet . Dell Deployment Automation 2.28.2502.13 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide. Dell Patch and Update Automation Tool 2.0.2502.16 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Dell RegisterJEA script 1.28.2502.11 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Dell Customer Toolkit 2502.5 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website. UpdateACL 1.1.2 N/A UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Windows Server 2022 LCU KB5051979 See the Windows support document KB5051979 . OS10 switch firmware (S5248, N3248) 10.6.0.1 OS10 switch firmware code is in the Dell Customer Toolkit. OEM extension package 2.4.2502.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload. Firmware Update Module in OEM Extension Package 2.2.2204.1 N/A
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version Scale Units (PowerEdge R740xd) R740xd N/A HGST HUH721212AL5200 Firmware DUP Storage - 12TB SAS HDD 9HXK6 8VV2X 04PM5 NS10 NS11 Scale Units (PowerEdge R740xd) R740xd N/A HGST HUS726T4TALS200 Firmware DUP Storage - 4TB SAS HDD NT1X2 8W21G J5K8G PU07 PU09 Scale Units (PowerEdge R740xd) R740xd N/A HGST HUS728T8TAL5200 Firmware DUP Storage - 8TB SAS HDD 44YFV 27MDM 8GM6M RS07 RS09 Hardware Lifecycle Host/HLH (PowerEdge R640) R640 N/A iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A XTFXJ C2VDG 7.00.00.173 7.00.00.174 Scale Units (PowerEdge R640 AS All Flash) R640 Scale Units (PowerEdge R640 Tactical) R640 Scale Units (PowerEdge R740xd) R740xd Scale Units (PowerEdge R840 AS Dense) R840 N/A 14G N/A S5248F-ON Switch Firmware TOR N/A DNVRC HD1V8 10.5.6.5 10.6.0.1 N/A 14G N/A N3248TE-ON Switch Firmware BMC N/A DNVRC HD1V8 10.5.6.5 10.6.0.1
1.1.5.2 - Release Artifacts for 16G - Dell 2502
Component File Name Supported Version Dell Integrated Systems for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2502.3_OEMPackage.zip 2502.3 Dell Integrated Systems for Microsoft Azure Stack Hub HLH ISO MS2406_Dell2502.5.iso 2502.5 Dell Integrated Systems for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2502.32_LifecycleManager.zip 2502.32
Software Versions
Component Version Notes Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal. Hardware Lifecycle Host 1.2406.0.8 N/A Hardware Lifecycle Host ISO 2502.5 N/A Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet . Windows Server 2022 LCU KB5051979 See the Windows support document KB5051979 . OS10 switch firmware (S5248) 10.6.0.1 OS10 switch firmware is included in the OEM Extension Package. OEM extension package 2.4.2502.3 Contains the driver and firmware update payload. OEM package 2502.3 Includes the OEM extension package.
Updated OEM Package components
Server Type Platform OS Type Component Type Category Dell P/N Previous SWB Target SWB Previous Version Target Version Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BIOS Firmware DUP BIOS N/A PJYMD K77XK 2.4.4 2.5.4 Scale Units (PowerEdge R760) R760 Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A BOSS-N1 Firmware DUP BOSS-N1 2MFVD 3P9J3 33TD2 2.1.13.2025 2.1.13.2033 Scale Units (PowerEdge R760) R760 Hardware Lifecycle Host/HLH (PowerEdge R760) R760 N/A iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 92MM7 5MXXN 7.10.90.00 7.20.10.50 Scale Units (PowerEdge R760) R760 N/A 16G N/A S5248F-ON Switch Firmware TOR N/A DNVRC HD1V8 10.5.6.5 10.6.0.1
1.2 - Release Notes
1.2.1 - Release Notes for Dell 2603
1.2.1.1 - Release Notes for 16G - Dell 2603
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2603 and Microsoft 2601
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2603 release and the Microsoft 2601 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 16G - Dell 2603 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2603 release and Microsoft 2601 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2601 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2601 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2601.0.4 Azure Stack Hub 2601 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2601.0.4 N/A
Hardware Lifecycle Host ISO 2603.6 N/A
Microsoft Partner Toolkit (PTK) 1.2601.3322.143 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5078766 See the Windows support document KB5078766 .
OS10 switch firmware (S5248) 10.6.1.0 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2603.10 Contains the driver and firmware update payload.
OEM package 2603.10 Includes the OEM extension package.
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.2 - Release Notes for Dell 2511
1.2.2.1 - Release Notes for 14G - Dell 2511
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2511 and Microsoft 2506
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2511 release and the Microsoft 2506 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 14G - Dell 2511 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2511 release and Microsoft 2506 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2506 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2506 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2511.4 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2511.15 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2511.14 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2511.10 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2511.6 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5068787 See the Windows support document KB5068787 .
OS10 switch firmware (S5248, N3248) 10.6.0.6 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2511.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.4.2504.1 N/A
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.2.2 - Release Notes for 16G - Dell 2511
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2511 and Microsoft 2506
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2511 release and the Microsoft 2506 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 16G - Dell 2511 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2511 release and Microsoft 2506 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2506 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2506 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2511.3 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5068787 See the Windows support document KB5068787 .
OS10 switch firmware (S5248) 10.6.0.6 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2511.2 Contains the driver and firmware update payload.
OEM package 2511.2 Includes the OEM extension package.
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.3 - Release Notes for Dell 2508
1.2.3.1 - Release Notes for 14G - Dell 2508
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2508 and Microsoft 2506
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2508 release and the Microsoft 2506 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 14G - Dell 2508 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2508 release and Microsoft 2506 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2506 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2506 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2508.7 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2508.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2508.6 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5063880 See the Windows support document KB5063880 .
OS10 switch firmware (S5248, N3248) 10.6.0.5 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2508.2 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.4.2504.1 N/A
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.3.2 - Release Notes for 16G - Dell 2508
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2508 and Microsoft 2506
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2508 release and the Microsoft 2506 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 16G - Dell 2508 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2508 release and Microsoft 2506 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2506 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2506 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2506.0.15 Azure Stack Hub 2506 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2506.0.13 N/A
Hardware Lifecycle Host ISO 2508.9 N/A
Microsoft Partner Toolkit (PTK) 1.2506.3141.132 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248) 10.6.0.5 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2508.4 Contains the driver and firmware update payload.
OEM package 2508.4 Includes the OEM extension package.
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.4 - Release Notes for Dell 2504
1.2.4.1 - Release Notes for 14G - Dell 2504
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2504 and Microsoft 2501
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2504 release and the Microsoft 2501 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 14G - Dell 2504 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2504 release and Microsoft 2501 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2501 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2501 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2406.0.8 N/A
Hardware Lifecycle Host ISO 2504.2 N/A
Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet .
Dell Deployment Automation 2.28.2504.50 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide.
Dell Patch and Update Automation Tool 2.0.2504.2 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell RegisterJEA script 1.28.2504.8 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Dell Customer Toolkit 2504.7 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website.
UpdateACL 1.1.2 N/A
UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide.
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248, N3248) 10.6.0.3 OS10 switch firmware code is in the Dell Customer Toolkit.
OEM extension package 2.4.2504.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload.
Firmware Update Module in OEM Extension Package 2.2.2204.1 N/A
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.4.2 - Release Notes for 16G - Dell 2504
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2504 and Microsoft 2501
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2504 release and the Microsoft 2501 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 16G - Dell 2504 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2504 release and Microsoft 2501 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2501 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2501 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes
Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal.
Hardware Lifecycle Host 1.2406.0.8 N/A
Hardware Lifecycle Host ISO 2504.6 N/A
Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet .
Windows Server 2022 LCU KB5058385 See the Windows support document KB5058385 .
OS10 switch firmware (S5248) 10.6.0.3 OS10 switch firmware is included in the OEM Extension Package.
OEM extension package 2.4.2504.2 Contains the driver and firmware update payload.
OEM package 2504.2 Includes the OEM extension package.
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.5 - Release Notes for Dell 2502
1.2.5.1 - Release Notes for 14G - Dell 2502
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2502 and Microsoft 2501
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2502 release and the Microsoft 2501 release.
New features, changed features, and fixes
New features
There are improvements and updates to drivers and firmware. See Release Artifacts for 14G - Dell 2502 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2502 release and Microsoft 2501 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2501 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2501 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal. Hardware Lifecycle Host 1.2406.0.8 N/A Hardware Lifecycle Host ISO 2502.12 N/A Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet . Dell Deployment Automation 2.28.2502.13 See the Dell Integrated System for Microsoft Azure Stack Hub Deployment Guide. Dell Patch and Update Automation Tool 2.0.2502.16 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Dell RegisterJEA script 1.28.2502.11 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Dell Customer Toolkit 2502.5 See Integrated System for Microsoft Azure Stack Hub 14G/Drivers & Downloads on the Dell Technologies Online Support website. UpdateACL 1.1.2 N/A UpdateWDAC 1.1.1 See the Dell Integrated System for Microsoft Azure Stack Hub Patch and Update Installation Guide. Windows Server 2022 LCU KB5051979 See the Windows support document KB5051979 . OS10 switch firmware (S5248, N3248) 10.6.0.1 OS10 switch firmware code is in the Dell Customer Toolkit. OEM extension package 2.4.2502.1 Included in the Dell Customer Toolkit and contains the driver and firmware update payload. Firmware Update Module in OEM Extension Package 2.2.2204.1 N/A
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.2.5.2 - Release Notes for 16G - Dell 2502
Dell Integrated System for Microsoft Azure Stack Hub Release Notes
Current Release Version: Dell 2502 and Microsoft 2501
Release Type: Major (MA)
NOTE
Dell Azure Stack Hub OEM updates must be installed in sequential order, it is not supported to skip or miss-out an OEM update version. These release notes contain supplemental information for the Dell 2502 release and the Microsoft 2501 release.
New features, changed features, and fixes
New features
Initial release of the Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager which provides an automated way of upgrading Hardware Lifecycle Host (HLH) firmware, software and driver components. See Patch and Update for 16G .
There are improvements and updates to drivers and firmware. See Release Artifacts for 16G - Dell 2502 .
Changed features
There are no changed features for this release.
Fixes
There are no fixes for this release.
Known issues and limitations
This release notes document describes known issues and limitations for the Dell Integrated System for Microsoft Azure Stack Hub solution based on the Dell 2502 release and Microsoft 2501 release.
Item
Description
OEM update
Dell Technologies recommends updating to the n-1 version before applying the latest OEM package.
Microsoft Azure Stack Hub code
For information about known issues and limitations in the Microsoft Azure Stack Hub code, see the Azure Stack Hub 2501 update on the Microsoft website
Notes and warnings
CAUTION
Before you use the Microsoft Patch and Update process to update Azure Stack Hub, close any active session to the ERCS virtual machines. If an active session is open, the update may fail, and must be resumed.
Microsoft fixed issues
For information about fixed issues in this release, see the Azure Stack Hub 2501 update on the Microsoft website.
Hardware and firmware support
For information about supported hardware, firmware, and software, see the Dell Integrated System for Microsoft Azure Stack Hub Support Matrix .
Software Versions
Component Version Notes Microsoft Azure Stack Hub Baseline (for bare-metal deployment) 1.2501.0.21 Azure Stack Hub 2501 update . The hotfix will be available in the Admin portal. Hardware Lifecycle Host 1.2406.0.8 N/A Hardware Lifecycle Host ISO 2502.5 N/A Microsoft Partner Toolkit (PTK) 1.2501.2966.112 Includes the Deployment Worksheet . Windows Server 2022 LCU KB5051979 See the Windows support document KB5051979 . OS10 switch firmware (S5248) 10.6.0.1 OS10 switch firmware is included in the OEM Extension Package. OEM extension package 2.4.2502.3 Contains the driver and firmware update payload. OEM package 2502.3 Includes the OEM extension package.
Additional resources
Dell Technologies resources
Additional Dell Technologies resources are available on the Dell Technologies Online Support website:
Microsoft resources
The following additional resources are available on the Microsoft website:
1.3 - Support Matrix
1.3.1 - Support Matrix for Dell 2603
1.3.1.1 - Support Matrix for 16G - Dell 2603
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2603 release and Microsoft 2601 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
16G Scale Units - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 FWT33 25.10.51000
HBA355i Driver DUP Storage - HBA K6MCJ M2P63 2.61.48.00
BIOS Firmware DUP BIOS N/A 457WM 2.9.4
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A XJG0V 1.2.7
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 924YT 7.30.10.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 XG5FJ 26.47.10.88
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A 58MWX 7.20
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
HBA355i Firmware DUP Storage - HBA K6MCJ CG0P9 33.15.00.00
16G Hardware Lifecycle Host - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 FWT33 25.10.51000
PERC H355 Adapter Driver DUP Storage - HBA VCV6T 6R1TD 7.730.02.00
BIOS Firmware DUP BIOS N/A 457WM 2.9.4
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A XJG0V 1.2.7
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 924YT 7.30.10.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 XG5FJ 26.47.10.88
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, IS Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A 58MWX 7.20
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
PERC H355 Adapter Firmware DUP Storage - HBA VCV6T 1DHXW 52.30.0-6347
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.1.0
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 760 GPU L40S 95.02.66.00.02
SFP Module S5248F-ON Platform
10 GbE SR LC SFP+ X
10 GbE LR LC SFP+ X
25 GbE SR LC SFP28+ X
25 GbE LR LC SFP28+ X
40 GbE SR BiDi QSFP+ X
40 GbE SR MTP/MPO QSFP+ X
40 GbE LR MTP/MPO QSFP+ X
100 GbE SR MTP/MPO QSFP28+ X
100 GbE LR MTP/MPO QSFP28+ X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2603.10_OEMPackage.zip 2603.10
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2601_Dell2603.6.iso 2603.6
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2603.2_LifecycleManager.zip 2603.2
1.3.2 - Support Matrix for Dell 2511
1.3.2.1 - Support Matrix for 14G - Dell 2511
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2511 release and Microsoft 2506 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
14G Scale Units - PowerEdge R740xd
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A PWYXM 25.07
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A 9M80P 2.25.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A G65GH 1.1.4
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A VP556 7.00.00.183
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD GD3N0 NGPR2 BA48
KIOXIA KPM7XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD 4TRHM N/A N/A
SAMSUNG MZILG1T6HCJRAD9 Firmware DUP Storage - 1.6TB SAS SSD TK47C N/A N/A
TOSHIBA PX05SMB160Y Firmware DUP Storage - 1.6TB SAS SSD GVTYD N/A N/A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 4CN85 NGPR2 BA48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V 1DJXX AS10
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
HGST HUH721010AL4200 Firmware DUP Storage - 10TB SAS HDD YG2KH MGW91 LS21
HGST HUH721010AL5200 Firmware DUP Storage - 10TB SAS HDD 07FPR MGW91 LS21
SEAGATE ST10000NM0256 Firmware DUP Storage - 10TB SAS HDD YF87J CD2WP TT56
SEAGATE ST10000NM0598 Firmware DUP Storage - 10TB SAS HDD HV5CH N/A N/A
TOSHIBA MG06SCA10TEY Firmware DUP Storage - 10TB SAS HDD 14YYC 4G5GY EH0D
TOSHIBA MG07SCA12TEY Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
HGST HUH721212AL5200 Firmware DUP Storage - 12TB SAS HDD 9HXK6 04PM5 NS11
SEAGATE ST12000NM006J Firmware DUP Storage - 12TB SAS HDD M1C0T N/A N/A
SEAGATE ST12000NM007H Firmware DUP Storage - 12TB SAS HDD FN7VR N/A N/A
SEAGATE ST12000NM009G Firmware DUP Storage - 12TB SAS HDD 7KT9W N/A N/A
SEAGATE ST12000NM0158 Firmware DUP Storage - 12TB SAS HDD YMN53 N/A N/A
TOSHIBA MG09SCA12TEY Firmware DUP Storage - 12TB SAS HDD 0N96X N/A N/A
INTEL D3-S45100 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
HGST HUS726040ALS210 Firmware DUP Storage - 4TB SAS HDD X4FKY N/A N/A
HGST HUS726T4TALS200 Firmware DUP Storage - 4TB SAS HDD NT1X2 J5K8G PU09
TOSHIBA MG04SCA40ENY Firmware DUP Storage - 4TB SAS HDD 1MVTT RG9MK EG03
TOSHIBA MG10SDA400NY Firmware DUP Storage - 4TB SAS HDD 9VN79 N/A N/A
SEAGATE ST4000NM017A Firmware DUP Storage - 4TB SAS HDD KRM6X N/A N/A
SEAGATE ST4000NM019B Firmware DUP Storage - 4TB SAS HDD 10N7R N/A N/A
SEAGATE ST4000NM0295 Firmware DUP Storage - 4TB SAS HDD W5M2R XKD4M DT34
SEAGATE ST6000NM035A Firmware DUP Storage - 6TB SAS HDD CVTK9 N/A N/A
TOSHIBA MG05ACA600E Firmware DUP Storage - 6TB SAS HDD 81Y15 N/A N/A
TOSHIBA MG06SCA600EY Firmware DUP Storage - 6TB SAS HDD XXPPV 4G5GY EH0D
KIOXIA KPM6XMUG800G Firmware DUP Storage - 800GB SAS SSD H6GCD NGPR2 BA48
KIOXIA KPM7XVUG800G Firmware DUP Storage - 800GB SAS SSD X96H8 N/A N/A
WESTERN DIGITAL WUSTM3280BSS200 Firmware DUP Storage - 800GB SAS SSD F99F6 N/A N/A
TOSHIBA PX05SMB080Y Firmware DUP Storage - 800GB SAS SSD CN3JH N/A N/A
SEAGATE ST8000NM0185 Firmware DUP Storage - 8TB SAS HDD M40TH 6421F PT55
TOSHIBA MG08SDA800EY Firmware DUP Storage - 8TB SAS HDD NJWMG N/A N/A
TOSHIBA MG10SDA800EY Firmware DUP Storage - 8TB SAS HDD VJDMM N/A N/A
HGST HUH721008AL4200 Firmware DUP Storage - 8TB SAS HDD CDDMJ MGW91 LS21
HGST HUH721008AL5200 Firmware DUP Storage - 8TB SAS HDD KRDKK MGW91 LS21
HGST HUS728T8TAL5200 Firmware DUP Storage - 8TB SAS HDD 44YFV 8GM6M RS09
SEAGATE ST8000NM014A Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
SEAGATE ST8000NM015A Firmware DUP Storage - 8TB SAS HDD K6646 N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD DKGYV N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD KNYW0 N/A N/A
SEAGATE ST8000NM024B Firmware DUP Storage - 8TB SAS HDD C5HD0 NM6GP LS0C
TOSHIBA MG06SCA800EY Firmware DUP Storage - 8TB SAS HDD FV725 4G5GY EH0D
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD J92FY 6DH0W BD48
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD WMWKG 6DH0W BD48
KIOXIA KPM7WRUG960G Firmware DUP Storage - 960GB SAS SSD T1RHN N/A N/A
KIOXIA KPM7XRUG960G Firmware DUP Storage - 960GB SAS SSD KRVY1 N/A N/A
KIOXIA KRM7VVUG960G Firmware DUP Storage - 960GB SAS SSD 05MT7 N/A N/A
SAMSUNG MZILG960HCHQAD9 Firmware DUP Storage - 960GB SAS SSD RX1JG N/A N/A
KIOXIA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
KIOXIA KPM6WRUG960G Firmware DUP Storage - 960GB SAS SSD R9RTY 6DH0W BD48
SEAGATE KRM6VVUG960G Firmware DUP Storage - 960GB SAS SSD 42XXC N/A N/A
SEAGATE XS960LE70134 Firmware DUP Storage - 960GB SAS SSD 2RDWT N/A N/A
SEAGATE XS960LE70154 Firmware DUP Storage - 960GB SAS SSD 38R6V N/A N/A
TOSHIBA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
TOSHIBA PX05SVB096Y Firmware DUP Storage - 960GB SAS SSD 503M7 N/A N/A
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
KIOXIA KRM7VRUG960G Firmware DUP Storage - 960GB vSAS SSD 6RNXC N/A N/A
SEAGATE XS960LE70095 Firmware DUP Storage - 960GB vSAS SSD 2M1NG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 All Flash
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A PWYXM 25.07
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A 9M80P 2.25.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A VP556 7.00.00.183
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V 1DJXX AS10
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 Tactical
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A PWYXM 25.07
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A 9M80P 2.25.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A VP556 7.00.00.183
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V 1DJXX AS10
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R840 Dense
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A PWYXM 25.07
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A V76F2 2.25.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 67GJY 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A VP556 7.00.00.183
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A NKNVC 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Hardware Lifecycle Host - PowerEdge R640
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Driver DUP Network N/A 6JHVK 23.0.0
PERC H330 Driver DUP SAS HBA - Internal N/A N/A Native
BIOS Firmware DUP BIOS N/A 9M80P 2.25.0
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A VP556 7.00.00.183
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Firmware DUP Network N/A H8M48 20.5.16
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
PERC H330 Firmware DUP SAS HBA - Internal N/A NYKX7 25.5.9.0001
HGST HUSTR7619ASS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) J68N1 N/A N/A
KIOXIA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
KIOXIA KPM6WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 7F2D1 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD (Boot) MFCD7 N/A N/A
SAMSUNG MZILS1T9HEJH0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 086DD N/A N/A
SAMSUNG MZILT1T9HAJQ0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) F0VFY N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 91DPV N/A N/A
TOSHIBA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
TOSHIBA PX05SRB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) 0FYFW N/A N/A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) V0K7V 1DJXX AS10
WESTERN DIGITAL WUSTVA119BSS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 02X38 N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) K805Y N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch N3248TE-ON MGMT 05WPCH 10.6.0.6
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.6
Z9100-ON Internal backend N/A 10.6.0.6
Cisco 9348GC-FXP MGMT N/A Minimum supported version:9.3(3)
Cisco 93180YC-FX ToR N/A Minimum supported version:9.3(3)
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 640 GPU T4 90.04.96.00.01
NVIDIA PowerEdge 840 Dense GPU V100s 88.00.98.00.01
NVIDIA PowerEdge 840 Dense GPU Mi25 N/A
SFP Module S3048-ON Platform N3248TE-ON Platform S4048-ON Platform S5048F-ON Platform S5248F-ON Platform
10 GbE SR LC SFP+ X X X X X
10 GbE LR LC SFP+ X X X X X
25 GbE SR LC SFP28+ X X
25 GbE LR LC SFP28+ X X
40 GbE SR BiDi QSFP+ X X X
40 GbE SR MTP/MPO QSFP+ X X X
40 GbE LR MTP/MPO QSFP+ X X X
100 GbE SR MTP/MPO QSFP28+ X X X
100 GbE LR MTP/MPO QSFP28+ X X X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2511.6.zip 2511.6
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2511.1.zip 2.4.2511.1
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2511.12_Redeployment.zip 2511.12
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2511.14.exe 2.0.2511.14
1.3.2.2 - Support Matrix for 16G - Dell 2511
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2511 release and Microsoft 2506 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
16G Scale Units - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 PWYXM 25.07
HBA355i Driver DUP Storage - HBA K6MCJ M2P63 2.61.48.00
BIOS Firmware DUP BIOS N/A 8NHX5 2.8.1
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A NK22D 7.20.60.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 K65HP 26.44.10.36
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A 58MWX 7.20
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
HBA355i Firmware DUP Storage - HBA K6MCJ Y99R5 24.15.14.00
16G Hardware Lifecycle Host - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 PWYXM 25.07
PERC H355 Adapter Driver DUP Storage - HBA VCV6T 6R1TD 7.730.02.00
BIOS Firmware DUP BIOS N/A 8NHX5 2.8.1
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A NK22D 7.20.60.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 K65HP 26.44.10.36
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, IS Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A 58MWX 7.20
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
PERC H355 Adapter Firmware DUP Storage - HBA VCV6T 1DHXW 52.30.0-6347
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.6
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 760 GPU L40S 95.02.66.00.02
SFP Module S5248F-ON Platform
10 GbE SR LC SFP+ X
10 GbE LR LC SFP+ X
25 GbE SR LC SFP28+ X
25 GbE LR LC SFP28+ X
40 GbE SR BiDi QSFP+ X
40 GbE SR MTP/MPO QSFP+ X
40 GbE LR MTP/MPO QSFP+ X
100 GbE SR MTP/MPO QSFP28+ X
100 GbE LR MTP/MPO QSFP28+ X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2511.2_OEMPackage.zip 2511.2
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2506_Dell2511.3.iso 2511.3
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2511.5_LifecycleManager.zip 2511.5
1.3.3 - Support Matrix for Dell 2508
1.3.3.1 - Support Matrix for 14G - Dell 2508
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2508 release and Microsoft 2506 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
14G Scale Units - PowerEdge R740xd
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A 3G71F 25.1
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A G65GH 1.1.4
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD GD3N0 NGPR2 BA48
KIOXIA KPM7XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD 4TRHM N/A N/A
SAMSUNG MZILG1T6HCJRAD9 Firmware DUP Storage - 1.6TB SAS SSD TK47C N/A N/A
TOSHIBA PX05SMB160Y Firmware DUP Storage - 1.6TB SAS SSD GVTYD N/A N/A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 4CN85 NGPR2 BA48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
HGST HUH721010AL4200 Firmware DUP Storage - 10TB SAS HDD YG2KH MGW91 LS21
HGST HUH721010AL5200 Firmware DUP Storage - 10TB SAS HDD 07FPR MGW91 LS21
SEAGATE ST10000NM0256 Firmware DUP Storage - 10TB SAS HDD YF87J CD2WP TT56
SEAGATE ST10000NM0598 Firmware DUP Storage - 10TB SAS HDD HV5CH N/A N/A
TOSHIBA MG06SCA10TEY Firmware DUP Storage - 10TB SAS HDD 14YYC 4G5GY EH0D
TOSHIBA MG07SCA12TEY Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
HGST HUH721212AL5200 Firmware DUP Storage - 12TB SAS HDD 9HXK6 04PM5 NS11
SEAGATE ST12000NM006J Firmware DUP Storage - 12TB SAS HDD M1C0T N/A N/A
SEAGATE ST12000NM007H Firmware DUP Storage - 12TB SAS HDD FN7VR N/A N/A
SEAGATE ST12000NM009G Firmware DUP Storage - 12TB SAS HDD 7KT9W N/A N/A
SEAGATE ST12000NM0158 Firmware DUP Storage - 12TB SAS HDD YMN53 N/A N/A
TOSHIBA MG09SCA12TEY Firmware DUP Storage - 12TB SAS HDD 0N96X N/A N/A
INTEL D3-S45100 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
HGST HUS726040ALS210 Firmware DUP Storage - 4TB SAS HDD X4FKY N/A N/A
HGST HUS726T4TALS200 Firmware DUP Storage - 4TB SAS HDD NT1X2 J5K8G PU09
TOSHIBA MG04SCA40ENY Firmware DUP Storage - 4TB SAS HDD 1MVTT RG9MK EG03
TOSHIBA MG10SDA400NY Firmware DUP Storage - 4TB SAS HDD 9VN79 N/A N/A
SEAGATE ST4000NM017A Firmware DUP Storage - 4TB SAS HDD KRM6X N/A N/A
SEAGATE ST4000NM019B Firmware DUP Storage - 4TB SAS HDD 10N7R N/A N/A
SEAGATE ST4000NM0295 Firmware DUP Storage - 4TB SAS HDD W5M2R XKD4M DT34
SEAGATE ST6000NM035A Firmware DUP Storage - 6TB SAS HDD CVTK9 N/A N/A
TOSHIBA MG05ACA600E Firmware DUP Storage - 6TB SAS HDD 81Y15 N/A N/A
TOSHIBA MG06SCA600EY Firmware DUP Storage - 6TB SAS HDD XXPPV 4G5GY EH0D
KIOXIA KPM6XMUG800G Firmware DUP Storage - 800GB SAS SSD H6GCD NGPR2 BA48
KIOXIA KPM7XVUG800G Firmware DUP Storage - 800GB SAS SSD X96H8 N/A N/A
WESTERN DIGITAL WUSTM3280BSS200 Firmware DUP Storage - 800GB SAS SSD F99F6 N/A N/A
TOSHIBA PX05SMB080Y Firmware DUP Storage - 800GB SAS SSD CN3JH N/A N/A
SEAGATE ST8000NM0185 Firmware DUP Storage - 8TB SAS HDD M40TH 6421F PT55
TOSHIBA MG08SDA800EY Firmware DUP Storage - 8TB SAS HDD NJWMG N/A N/A
TOSHIBA MG10SDA800EY Firmware DUP Storage - 8TB SAS HDD VJDMM N/A N/A
HGST HUH721008AL4200 Firmware DUP Storage - 8TB SAS HDD CDDMJ MGW91 LS21
HGST HUH721008AL5200 Firmware DUP Storage - 8TB SAS HDD KRDKK MGW91 LS21
HGST HUS728T8TAL5200 Firmware DUP Storage - 8TB SAS HDD 44YFV 8GM6M RS09
SEAGATE ST8000NM014A Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
SEAGATE ST8000NM015A Firmware DUP Storage - 8TB SAS HDD K6646 N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD DKGYV N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD KNYW0 N/A N/A
SEAGATE ST8000NM024B Firmware DUP Storage - 8TB SAS HDD C5HD0 NM6GP LS0C
TOSHIBA MG06SCA800EY Firmware DUP Storage - 8TB SAS HDD FV725 4G5GY EH0D
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD J92FY 6DH0W BD48
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD WMWKG 6DH0W BD48
KIOXIA KPM7WRUG960G Firmware DUP Storage - 960GB SAS SSD T1RHN N/A N/A
KIOXIA KPM7XRUG960G Firmware DUP Storage - 960GB SAS SSD KRVY1 N/A N/A
KIOXIA KRM7VVUG960G Firmware DUP Storage - 960GB SAS SSD 05MT7 N/A N/A
SAMSUNG MZILG960HCHQAD9 Firmware DUP Storage - 960GB SAS SSD RX1JG N/A N/A
KIOXIA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
KIOXIA KPM6WRUG960G Firmware DUP Storage - 960GB SAS SSD R9RTY 6DH0W BD48
SEAGATE KRM6VVUG960G Firmware DUP Storage - 960GB SAS SSD 42XXC N/A N/A
SEAGATE XS960LE70134 Firmware DUP Storage - 960GB SAS SSD 2RDWT N/A N/A
SEAGATE XS960LE70154 Firmware DUP Storage - 960GB SAS SSD 38R6V N/A N/A
TOSHIBA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
TOSHIBA PX05SVB096Y Firmware DUP Storage - 960GB SAS SSD 503M7 N/A N/A
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
KIOXIA KRM7VRUG960G Firmware DUP Storage - 960GB vSAS SSD 6RNXC N/A N/A
SEAGATE XS960LE70095 Firmware DUP Storage - 960GB vSAS SSD 2M1NG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 All Flash
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A 3G71F 25.1
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 Tactical
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A 3G71F 25.1
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R840 Dense
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A 3G71F 25.1
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A NW297 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 67GJY 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A NKNVC 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Hardware Lifecycle Host - PowerEdge R640
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Driver DUP Network N/A 6JHVK 23.0.0
PERC H330 Driver DUP SAS HBA - Internal N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Firmware DUP Network N/A H8M48 20.5.16
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
PERC H330 Firmware DUP SAS HBA - Internal N/A NYKX7 25.5.9.0001
HGST HUSTR7619ASS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) J68N1 N/A N/A
KIOXIA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
KIOXIA KPM6WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 7F2D1 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD (Boot) MFCD7 N/A N/A
SAMSUNG MZILS1T9HEJH0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 086DD N/A N/A
SAMSUNG MZILT1T9HAJQ0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) F0VFY N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 91DPV N/A N/A
TOSHIBA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
TOSHIBA PX05SRB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) 0FYFW N/A N/A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) V0K7V N/A N/A
WESTERN DIGITAL WUSTVA119BSS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 02X38 N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) K805Y N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch N3248TE-ON MGMT 05WPCH 10.6.0.5
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.5
Z9100-ON Internal backend N/A 10.6.0.5
Cisco 9348GC-FXP MGMT N/A Minimum supported version:9.3(3)
Cisco 93180YC-FX ToR N/A Minimum supported version:9.3(3)
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 640 GPU T4 90.04.96.00.01
NVIDIA PowerEdge 840 Dense GPU V100s 88.00.98.00.01
NVIDIA PowerEdge 840 Dense GPU Mi25 N/A
SFP Module S3048-ON Platform N3248TE-ON Platform S4048-ON Platform S5048F-ON Platform S5248F-ON Platform
10 GbE SR LC SFP+ X X X X X
10 GbE LR LC SFP+ X X X X X
25 GbE SR LC SFP28+ X X
25 GbE LR LC SFP28+ X X
40 GbE SR BiDi QSFP+ X X X
40 GbE SR MTP/MPO QSFP+ X X X
40 GbE LR MTP/MPO QSFP+ X X X
100 GbE SR MTP/MPO QSFP28+ X X X
100 GbE LR MTP/MPO QSFP28+ X X X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2508.6.zip 2508.6
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2508.2.zip 2.4.2508.2
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2508.7_Redeployment.zip 2508.7
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2508.1.exe 2.0.2508.1
1.3.3.2 - Support Matrix for 16G - Dell 2508
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2508 release and Microsoft 2506 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
16G Scale Units - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 3G71F 25.1
HBA355i Driver DUP Storage - HBA K6MCJ M2P63 2.61.48.00
BIOS Firmware DUP BIOS N/A W23G7 2.7.5
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 6CKFT 7.20.60.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.1000
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
HBA355i Firmware DUP Storage - HBA K6MCJ Y99R5 24.15.14.00
16G Hardware Lifecycle Host - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 3G71F 25.1
PERC H355 Adapter Driver DUP Storage - HBA VCV6T 6R1TD 7.730.02.00
BIOS Firmware DUP BIOS N/A W23G7 2.7.5
BOSS-N1 Firmware DUP BOSS-N1 2MFVD C6MVR 2.1.13.2037
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 6CKFT 7.20.60.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.1000
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, IS Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
PERC H355 Adapter Firmware DUP Storage - HBA VCV6T PXRX0 52.30.0-6115
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.5
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 760 GPU L40S 95.02.66.00.02
SFP Module S5248F-ON Platform
10 GbE SR LC SFP+ X
10 GbE LR LC SFP+ X
25 GbE SR LC SFP28+ X
25 GbE LR LC SFP28+ X
40 GbE SR BiDi QSFP+ X
40 GbE SR MTP/MPO QSFP+ X
40 GbE LR MTP/MPO QSFP+ X
100 GbE SR MTP/MPO QSFP28+ X
100 GbE LR MTP/MPO QSFP28+ X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2508.4_OEMPackage.zip 2508.4
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2506_Dell2508.9.iso 2508.9
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2508.3_LifecycleManager.zip 2508.3
1.3.4 - Support Matrix for Dell 2504
1.3.4.1 - Support Matrix for 14G - Dell 2504
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2504 release and Microsoft 2501 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
14G Scale Units - PowerEdge R740xd
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A G65GH 1.1.4
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD GD3N0 NGPR2 BA48
KIOXIA KPM7XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD 4TRHM N/A N/A
SAMSUNG MZILG1T6HCJRAD9 Firmware DUP Storage - 1.6TB SAS SSD TK47C N/A N/A
TOSHIBA PX05SMB160Y Firmware DUP Storage - 1.6TB SAS SSD GVTYD N/A N/A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 4CN85 NGPR2 BA48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
HGST HUH721010AL4200 Firmware DUP Storage - 10TB SAS HDD YG2KH MGW91 LS21
HGST HUH721010AL5200 Firmware DUP Storage - 10TB SAS HDD 07FPR MGW91 LS21
SEAGATE ST10000NM0256 Firmware DUP Storage - 10TB SAS HDD YF87J CD2WP TT56
SEAGATE ST10000NM0598 Firmware DUP Storage - 10TB SAS HDD HV5CH N/A N/A
TOSHIBA MG06SCA10TEY Firmware DUP Storage - 10TB SAS HDD 14YYC 4G5GY EH0D
TOSHIBA MG07SCA12TEY Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
HGST HUH721212AL5200 Firmware DUP Storage - 12TB SAS HDD 9HXK6 04PM5 NS11
SEAGATE ST12000NM006J Firmware DUP Storage - 12TB SAS HDD M1C0T N/A N/A
SEAGATE ST12000NM007H Firmware DUP Storage - 12TB SAS HDD FN7VR N/A N/A
SEAGATE ST12000NM009G Firmware DUP Storage - 12TB SAS HDD 7KT9W N/A N/A
SEAGATE ST12000NM0158 Firmware DUP Storage - 12TB SAS HDD YMN53 N/A N/A
TOSHIBA MG09SCA12TEY Firmware DUP Storage - 12TB SAS HDD 0N96X N/A N/A
INTEL D3-S45100 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
HGST HUS726040ALS210 Firmware DUP Storage - 4TB SAS HDD X4FKY N/A N/A
HGST HUS726T4TALS200 Firmware DUP Storage - 4TB SAS HDD NT1X2 J5K8G PU09
TOSHIBA MG04SCA40ENY Firmware DUP Storage - 4TB SAS HDD 1MVTT RG9MK EG03
TOSHIBA MG10SDA400NY Firmware DUP Storage - 4TB SAS HDD 9VN79 N/A N/A
SEAGATE ST4000NM017A Firmware DUP Storage - 4TB SAS HDD KRM6X N/A N/A
SEAGATE ST4000NM019B Firmware DUP Storage - 4TB SAS HDD 10N7R N/A N/A
SEAGATE ST4000NM0295 Firmware DUP Storage - 4TB SAS HDD W5M2R XKD4M DT34
SEAGATE ST6000NM035A Firmware DUP Storage - 6TB SAS HDD CVTK9 N/A N/A
TOSHIBA MG05ACA600E Firmware DUP Storage - 6TB SAS HDD 81Y15 N/A N/A
TOSHIBA MG06SCA600EY Firmware DUP Storage - 6TB SAS HDD XXPPV 4G5GY EH0D
KIOXIA KPM6XMUG800G Firmware DUP Storage - 800GB SAS SSD H6GCD NGPR2 BA48
KIOXIA KPM7XVUG800G Firmware DUP Storage - 800GB SAS SSD X96H8 N/A N/A
WESTERN DIGITAL WUSTM3280BSS200 Firmware DUP Storage - 800GB SAS SSD F99F6 N/A N/A
TOSHIBA PX05SMB080Y Firmware DUP Storage - 800GB SAS SSD CN3JH N/A N/A
SEAGATE ST8000NM0185 Firmware DUP Storage - 8TB SAS HDD M40TH 6421F PT55
TOSHIBA MG08SDA800EY Firmware DUP Storage - 8TB SAS HDD NJWMG N/A N/A
TOSHIBA MG10SDA800EY Firmware DUP Storage - 8TB SAS HDD VJDMM N/A N/A
HGST HUH721008AL4200 Firmware DUP Storage - 8TB SAS HDD CDDMJ MGW91 LS21
HGST HUH721008AL5200 Firmware DUP Storage - 8TB SAS HDD KRDKK MGW91 LS21
HGST HUS728T8TAL5200 Firmware DUP Storage - 8TB SAS HDD 44YFV 8GM6M RS09
SEAGATE ST8000NM014A Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
SEAGATE ST8000NM015A Firmware DUP Storage - 8TB SAS HDD K6646 N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD DKGYV N/A N/A
SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD KNYW0 N/A N/A
SEAGATE ST8000NM024B Firmware DUP Storage - 8TB SAS HDD C5HD0 NM6GP LS0C
TOSHIBA MG06SCA800EY Firmware DUP Storage - 8TB SAS HDD FV725 4G5GY EH0D
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD J92FY 6DH0W BD48
KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD WMWKG 6DH0W BD48
KIOXIA KPM7WRUG960G Firmware DUP Storage - 960GB SAS SSD T1RHN N/A N/A
KIOXIA KPM7XRUG960G Firmware DUP Storage - 960GB SAS SSD KRVY1 N/A N/A
KIOXIA KRM7VVUG960G Firmware DUP Storage - 960GB SAS SSD 05MT7 N/A N/A
SAMSUNG MZILG960HCHQAD9 Firmware DUP Storage - 960GB SAS SSD RX1JG N/A N/A
KIOXIA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
KIOXIA KPM6WRUG960G Firmware DUP Storage - 960GB SAS SSD R9RTY 6DH0W BD48
SEAGATE KRM6VVUG960G Firmware DUP Storage - 960GB SAS SSD 42XXC N/A N/A
SEAGATE XS960LE70134 Firmware DUP Storage - 960GB SAS SSD 2RDWT N/A N/A
SEAGATE XS960LE70154 Firmware DUP Storage - 960GB SAS SSD 38R6V N/A N/A
TOSHIBA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A
TOSHIBA PX05SVB096Y Firmware DUP Storage - 960GB SAS SSD 503M7 N/A N/A
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
KIOXIA KRM7VRUG960G Firmware DUP Storage - 960GB vSAS SSD 6RNXC N/A N/A
SEAGATE XS960LE70095 Firmware DUP Storage - 960GB vSAS SSD 2M1NG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 All Flash
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 Tactical
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R840 Dense
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03
Dell HBA330 Driver DUP Storage - HBA N/A N/A Native
BIOS Firmware DUP BIOS N/A NW297 2.24.0
BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024
CPLD Firmware DUP CPLD N/A 67GJY 1.0.6
iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A 76DNG 14.32.21.02
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48
KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A
KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A
SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A
KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48
KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A
KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A
KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A
KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A
SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A
SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A
SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A
TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A
TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A
KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A
SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A
SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A
INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43
INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R
INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 VJPKG DL7C
INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 VJPKG DL7C
MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013
MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004
MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003
KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48
INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H VJPKG DL7C
INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH VJPKG DL7C
MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
Dell HBA330 Firmware DUP Storage - HBA N/A NKNVC 16.17.01.00
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Hardware Lifecycle Host - PowerEdge R640
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Driver DUP Network N/A 6JHVK 23.0.0
PERC H330 Driver DUP SAS HBA - Internal N/A N/A Native
BIOS Firmware DUP BIOS N/A T4VCN 2.24.0
CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6
iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A RVDDR 7.00.00.181
INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Firmware DUP Network N/A H8M48 20.5.16
Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35
PERC H330 Firmware DUP SAS HBA - Internal N/A NYKX7 25.5.9.0001
HGST HUSTR7619ASS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) J68N1 N/A N/A
KIOXIA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
KIOXIA KPM6WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 7F2D1 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 1081V 6DH0W BD48
KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) DHWH5 6DH0W BD48
KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) VGMCD N/A N/A
KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 6K35K N/A N/A
KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N15JP N/A N/A
KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 59XF2 N/A N/A
SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD (Boot) MFCD7 N/A N/A
SAMSUNG MZILS1T9HEJH0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 086DD N/A N/A
SAMSUNG MZILT1T9HAJQ0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) F0VFY N/A N/A
SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N6DRV N/A N/A
SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 91DPV N/A N/A
TOSHIBA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A
TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A
TOSHIBA PX05SRB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) 0FYFW N/A N/A
TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) V0K7V N/A N/A
WESTERN DIGITAL WUSTVA119BSS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 02X38 N/A N/A
KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) 86XW7 N/A N/A
SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) K805Y N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52
uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch N3248TE-ON MGMT 05WPCH 10.6.0.3
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.3
Z9100-ON Internal backend N/A 10.6.0.3
Cisco 9348GC-FXP MGMT N/A Minimum supported version:9.3(3)
Cisco 93180YC-FX ToR N/A Minimum supported version:9.3(3)
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 640 GPU T4 90.04.96.00.01
NVIDIA PowerEdge 840 Dense GPU V100s 88.00.98.00.01
NVIDIA PowerEdge 840 Dense GPU Mi25 N/A
SFP Module S3048-ON Platform N3248TE-ON Platform S4048-ON Platform S5048F-ON Platform S5248F-ON Platform
10 GbE SR LC SFP+ X X X X X
10 GbE LR LC SFP+ X X X X X
25 GbE SR LC SFP28+ X X
25 GbE LR LC SFP28+ X X
40 GbE SR BiDi QSFP+ X X X
40 GbE SR MTP/MPO QSFP+ X X X
40 GbE LR MTP/MPO QSFP+ X X X
100 GbE SR MTP/MPO QSFP28+ X X X
100 GbE LR MTP/MPO QSFP28+ X X X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2504.7.zip 2504.7
Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2504.1.zip 2.4.2504.1
Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2504.5_Redeployment.zip 2504.5
Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2504.2.exe 2.0.2504.2
1.3.4.2 - Support Matrix for 16G - Dell 2504
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2504 release and Microsoft 2501 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
16G Scale Units - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 3G71F 25.1
HBA355i Driver DUP Storage - HBA K6MCJ M2P63 2.61.48.00
BIOS Firmware DUP BIOS N/A XK9CT 2.6.3
BOSS-N1 Firmware DUP BOSS-N1 2MFVD 33TD2 2.1.13.2033
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A WN31M 7.20.30.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.10.00
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
HBA355i Firmware DUP Storage - HBA K6MCJ Y99R5 24.15.14.00
16G Hardware Lifecycle Host - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version
BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox
Chipset driver for 16G Intel platforms Driver DUP Chipset N/A R40PW 10.1.19928.8615
Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 3G71F 25.1
PERC H355 Adapter Driver DUP Storage - HBA VCV6T 6R1TD 7.730.02.00
BIOS Firmware DUP BIOS N/A XK9CT 2.6.3
BOSS-N1 Firmware DUP BOSS-N1 2MFVD 33TD2 2.1.13.2033
CPLD Firmware DUP CPLD N/A 503F0 1.2.6
iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A WN31M 7.20.30.50
Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.10.00
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48
MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A
PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A
Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A
PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48
7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A
Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A
CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A
CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A
CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A
PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A
PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A
PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A
PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A
PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, IS Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A
PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A
PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48
PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A
Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A
7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A
7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A
PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A
PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A
Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61
Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1
NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A R39FM 3.33
PERC H355 Adapter Firmware DUP Storage - HBA VCV6T PXRX0 52.30.0-6115
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version
Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.3
Other Components
Vendor Platform Component Model Firmware
NVIDIA PowerEdge 760 GPU L40S 95.02.66.00.02
SFP Module S5248F-ON Platform
10 GbE SR LC SFP+ X
10 GbE LR LC SFP+ X
25 GbE SR LC SFP28+ X
25 GbE LR LC SFP28+ X
40 GbE SR BiDi QSFP+ X
40 GbE SR MTP/MPO QSFP+ X
40 GbE LR MTP/MPO QSFP+ X
100 GbE SR MTP/MPO QSFP28+ X
100 GbE LR MTP/MPO QSFP28+ X
2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version
Dell Integrated System for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2504.2_OEMPackage.zip 2504.2
Dell Integrated System for Microsoft Azure Stack Hub HLH ISO MS2406_Dell2504.6.iso 2504.6
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2504.2_LifecycleManager.zip 2504.2
1.3.5 - Support Matrix for Dell 2502
1.3.5.1 - Support Matrix for 14G - Dell 2502
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2502 release and Microsoft 2501 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
14G Scale Units - PowerEdge R740xd
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03 Dell HBA330 Driver DUP Storage - HBA N/A N/A Native BIOS Firmware DUP BIOS N/A F8GPH 2.22.2 BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024 CPLD Firmware DUP CPLD N/A G65GH 1.1.4 iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG 7.00.00.174 Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A PY7FC 14.32.20.04 Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35 KIOXIA KPM6XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD GD3N0 NGPR2 BA48 KIOXIA KPM7XVUG1T60 Firmware DUP Storage - 1.6TB SAS SSD 4TRHM N/A N/A SAMSUNG MZILG1T6HCJRAD9 Firmware DUP Storage - 1.6TB SAS SSD TK47C N/A N/A TOSHIBA PX05SMB160Y Firmware DUP Storage - 1.6TB SAS SSD GVTYD N/A N/A KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A KIOXIA KPM6XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 4CN85 NGPR2 BA48 KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A HGST HUH721010AL4200 Firmware DUP Storage - 10TB SAS HDD YG2KH MGW91 LS21 HGST HUH721010AL5200 Firmware DUP Storage - 10TB SAS HDD 07FPR MGW91 LS21 SEAGATE ST10000NM0256 Firmware DUP Storage - 10TB SAS HDD YF87J CD2WP TT56 SEAGATE ST10000NM0598 Firmware DUP Storage - 10TB SAS HDD HV5CH N/A N/A TOSHIBA MG06SCA10TEY Firmware DUP Storage - 10TB SAS HDD 14YYC 4G5GY EH0D TOSHIBA MG07SCA12TEY Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D HGST HUH721212AL5200 Firmware DUP Storage - 12TB SAS HDD 9HXK6 04PM5 NS11 SEAGATE ST12000NM006J Firmware DUP Storage - 12TB SAS HDD M1C0T N/A N/A SEAGATE ST12000NM007H Firmware DUP Storage - 12TB SAS HDD FN7VR N/A N/A SEAGATE ST12000NM009G Firmware DUP Storage - 12TB SAS HDD 7KT9W N/A N/A SEAGATE ST12000NM0158 Firmware DUP Storage - 12TB SAS HDD YMN53 N/A N/A TOSHIBA MG09SCA12TEY Firmware DUP Storage - 12TB SAS HDD 0N96X N/A N/A INTEL D3-S45100 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43 INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X DL7A INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 9RF8X DL7A MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013 MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004 MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003 HGST HUS726040ALS210 Firmware DUP Storage - 4TB SAS HDD X4FKY N/A N/A HGST HUS726T4TALS200 Firmware DUP Storage - 4TB SAS HDD NT1X2 J5K8G PU09 TOSHIBA MG04SCA40ENY Firmware DUP Storage - 4TB SAS HDD 1MVTT RG9MK EG03 TOSHIBA MG10SDA400NY Firmware DUP Storage - 4TB SAS HDD 9VN79 N/A N/A SEAGATE ST4000NM017A Firmware DUP Storage - 4TB SAS HDD KRM6X N/A N/A SEAGATE ST4000NM019B Firmware DUP Storage - 4TB SAS HDD 10N7R N/A N/A SEAGATE ST4000NM0295 Firmware DUP Storage - 4TB SAS HDD W5M2R XKD4M DT34 SEAGATE ST6000NM035A Firmware DUP Storage - 6TB SAS HDD CVTK9 N/A N/A TOSHIBA MG05ACA600E Firmware DUP Storage - 6TB SAS HDD 81Y15 N/A N/A TOSHIBA MG06SCA600EY Firmware DUP Storage - 6TB SAS HDD XXPPV 4G5GY EH0D KIOXIA KPM6XMUG800G Firmware DUP Storage - 800GB SAS SSD H6GCD NGPR2 BA48 KIOXIA KPM7XVUG800G Firmware DUP Storage - 800GB SAS SSD X96H8 N/A N/A WESTERN DIGITAL WUSTM3280BSS200 Firmware DUP Storage - 800GB SAS SSD F99F6 N/A N/A TOSHIBA PX05SMB080Y Firmware DUP Storage - 800GB SAS SSD CN3JH N/A N/A SEAGATE ST8000NM0185 Firmware DUP Storage - 8TB SAS HDD M40TH 6421F PT55 TOSHIBA MG08SDA800EY Firmware DUP Storage - 8TB SAS HDD NJWMG N/A N/A TOSHIBA MG10SDA800EY Firmware DUP Storage - 8TB SAS HDD VJDMM N/A N/A HGST HUH721008AL4200 Firmware DUP Storage - 8TB SAS HDD CDDMJ MGW91 LS21 HGST HUH721008AL5200 Firmware DUP Storage - 8TB SAS HDD KRDKK MGW91 LS21 HGST HUS728T8TAL5200 Firmware DUP Storage - 8TB SAS HDD 44YFV 8GM6M RS09 SEAGATE ST8000NM014A Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A SEAGATE ST8000NM015A Firmware DUP Storage - 8TB SAS HDD K6646 N/A N/A SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD DKGYV N/A N/A SEAGATE ST8000NM0195 Firmware DUP Storage - 8TB SAS HDD KNYW0 N/A N/A SEAGATE ST8000NM024B Firmware DUP Storage - 8TB SAS HDD C5HD0 NM6GP LS0C TOSHIBA MG06SCA800EY Firmware DUP Storage - 8TB SAS HDD FV725 4G5GY EH0D KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD J92FY 6DH0W BD48 KIOXIA KPM6WVUG960G Firmware DUP Storage - 960GB SAS SSD WMWKG 6DH0W BD48 KIOXIA KPM7WRUG960G Firmware DUP Storage - 960GB SAS SSD T1RHN N/A N/A KIOXIA KPM7XRUG960G Firmware DUP Storage - 960GB SAS SSD KRVY1 N/A N/A KIOXIA KRM7VVUG960G Firmware DUP Storage - 960GB SAS SSD 05MT7 N/A N/A SAMSUNG MZILG960HCHQAD9 Firmware DUP Storage - 960GB SAS SSD RX1JG N/A N/A KIOXIA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A KIOXIA KPM6WRUG960G Firmware DUP Storage - 960GB SAS SSD R9RTY 6DH0W BD48 SEAGATE KRM6VVUG960G Firmware DUP Storage - 960GB SAS SSD 42XXC N/A N/A SEAGATE XS960LE70134 Firmware DUP Storage - 960GB SAS SSD 2RDWT N/A N/A SEAGATE XS960LE70154 Firmware DUP Storage - 960GB SAS SSD 38R6V N/A N/A TOSHIBA KPM5XVUG960G Firmware DUP Storage - 960GB SAS SSD WFGTH CPP97 B02A TOSHIBA PX05SVB096Y Firmware DUP Storage - 960GB SAS SSD 503M7 N/A N/A INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH 9RF8X DL7A MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003 KIOXIA KRM7VRUG960G Firmware DUP Storage - 960GB vSAS SSD 6RNXC N/A N/A SEAGATE XS960LE70095 Firmware DUP Storage - 960GB vSAS SSD 2M1NG N/A N/A Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52 Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00 uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 All Flash
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03 Dell HBA330 Driver DUP Storage - HBA N/A N/A Native BIOS Firmware DUP BIOS N/A F8GPH 2.22.2 BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024 CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6 iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG 7.00.00.174 Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A PY7FC 14.32.20.04 Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35 KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48 KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48 KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48 KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48 KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43 INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X DL7A INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 9RF8X DL7A MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013 MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004 MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003 KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48 INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH 9RF8X DL7A MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003 Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52 Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00 uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R640 Tactical
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03 Dell HBA330 Driver DUP Storage - HBA N/A N/A Native BIOS Firmware DUP BIOS N/A F8GPH 2.22.2 BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024 CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6 iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG 7.00.00.174 Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A PY7FC 14.32.20.04 Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35 KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 1081V 6DH0W BD48 KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD DHWH5 6DH0W BD48 KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD VGMCD N/A N/A KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 6K35K N/A N/A KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD N15JP N/A N/A KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 59XF2 N/A N/A SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD MFCD7 N/A N/A SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD N6DRV N/A N/A SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD 91DPV N/A N/A TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD 2WVYG CPP97 B02A TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD V0K7V N/A N/A KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD 86XW7 N/A N/A SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD K805Y N/A N/A KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48 KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43 INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X DL7A INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 9RF8X DL7A MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013 MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004 MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003 KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48 INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH 9RF8X DL7A MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003 Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52 Dell HBA330 Firmware DUP Storage - HBA N/A 124X2 16.17.01.00 uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Scale Units - PowerEdge R840 Dense
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607 Mellanox ConnectX-4 LX / 25GbE Driver DUP Network / RDMA N/A G6M58 24.04.03 Dell HBA330 Driver DUP Storage - HBA N/A N/A Native BIOS Firmware DUP BIOS N/A 5T6CY 2.22.1 BOSS-S1 Firmware Firmware DUP BOSS-S1 N/A 3P39V 2.5.13.3024 CPLD Firmware DUP CPLD N/A 67GJY 1.0.6 iDRAC with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG 7.00.00.174 Mellanox ConnectX-4 LX / 25GbE Firmware DUP Network/RDMA N/A PY7FC 14.32.20.04 Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35 KIOXIA KPM6XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD NKM7P NGPR2 BA48 KIOXIA KPM7WVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD RGP9J N/A N/A KIOXIA KPM7XVUG3T20 Firmware DUP Storage - 3.2TB SAS SSD V0X40 N/A N/A SAMSUNG MZILG3T2HCLSAD9 Firmware DUP Storage - 3.2TB SAS SSD 5DVPV N/A N/A KIOXIA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A KIOXIA KPM6WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FH1W9 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48 KIOXIA KPM6WVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 81H9C 6DH0W BD48 KIOXIA KPM7WRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD YTVTF N/A N/A KIOXIA KPM7XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD MT0R5 N/A N/A KIOXIA KRM6VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD FXYGR N/A N/A KIOXIA KRM7VVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD M0JVN N/A N/A SAMSUNG MZILG3T8HCLSAD9 Firmware DUP Storage - 3.84TB SAS SSD H62RF N/A N/A SEAGATE XS3840LE70134 Firmware DUP Storage - 3.84TB SAS SSD YM9HP N/A N/A SEAGATE XS3840LE70154 Firmware DUP Storage - 3.84TB SAS SSD NWGX3 N/A N/A TOSHIBA KPM5XVUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 91W3V CPP97 B02A TOSHIBA PX05SVB384Y Firmware DUP Storage - 3.84TB SAS SSD 3DDFT N/A N/A KIOXIA KRM7VRUG3T84 Firmware DUP Storage - 3.84TB vSAS SSD VJNDD N/A N/A SEAGATE XS3840LE70095 Firmware DUP Storage - 3.84TB vSAS SSD FT95M N/A N/A SEAGATE XS3840LE70115 Firmware DUP Storage - 3.84TB vSAS SSD DHK7V N/A N/A INTEL S3520 RI M.2 SSD SSDSCKJB480G7R (Boot) Firmware DUP Storage - 480GB SATA SSD WCP9P CHJGV DL43 INTEL S4510 RI M.2 SSD SSDSCKKB480G8R (Boot) Firmware DUP Storage - 480GB SATA SSD 7FXC3 Y1P10 DL6R INTEL S4520 RR M.2 SSD SSDSC2KB960GZR (Boot) Firmware DUP Storage - 480GB SATA SSD GX439 9RF8X DL7A INTEL S4520 RR M.2 SSD SSDSCKKB480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD M7F5D 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG480GZR (Boot) Firmware DUP Storage - 480GB SATA SSD 00DJ5 9RF8X DL7A MICRON 5100 Pro M.2 SSD MTFDDAV480TCB (Boot) Firmware DUP Storage - 480GB SATA SSD GPGC0 YM8KY E013 MICRON 5300 Pro M.2 SSD MTFDDAV480TDS (Boot) Firmware DUP Storage - 480GB SATA SSD 7RKD7 PWVX5 J004 MICRON 5400 Pro M.2 SSD MTFDDAV480TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 480GB SATA SSD VN68H RJ0WY K003 KIOXIA KPM6XVUG6T40 Firmware DUP Storage - 6.4TB SAS SSD 6NW3J NGPR2 BA48 INTEL S4520 RR M.2 SSD SSDSC2KB480GZR (Boot) Firmware DUP Storage - 960GB SATA SSD F6H8H 9RF8X DL7A INTEL S4620 RR M.2 SSD SSDSC2KG960GZR (Boot) Firmware DUP Storage - 960GB SATA SSD 8MHYH 9RF8X DL7A MICRON 5400 Pro M.2 SSD MTFDDAV960TGA-1BC1ZABDA (Boot) Firmware DUP Storage - 960GB SATA SSD KHRN0 RJ0WY K003 Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52 Dell HBA330 Firmware DUP Storage - HBA N/A NKNVC 16.17.01.00 uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
14G Hardware Lifecycle Host - PowerEdge R640
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version INTEL C600/C610/C220/C230/C2000 Series Driver DUP Chipset N/A 4DDMJ 10.1.19913.8607 INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Driver DUP Network N/A 6JHVK 23.0.0 PERC H330 Driver DUP SAS HBA - Internal N/A N/A Native BIOS Firmware DUP BIOS N/A F8GPH 2.22.2 CPLD Firmware DUP CPLD N/A 9N4DH 1.0.6 iDRAC with Lifecycle controller Firmware DUP iDRAC with Lifecycle Controller N/A C2VDG 7.00.00.174 INTEL X710 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, NDC Firmware DUP Network N/A H8M48 20.5.16 Dell SEP Non-expander Storage Backplane Firmware DUP Non-expander Storage Backplane N/A VV85D 4.35 PERC H330 Firmware DUP SAS HBA - Internal N/A NYKX7 25.5.9.0001 HGST HUSTR7619ASS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) J68N1 N/A N/A KIOXIA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A KIOXIA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A KIOXIA KPM6WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 7F2D1 6DH0W BD48 KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 1081V 6DH0W BD48 KIOXIA KPM6WVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) DHWH5 6DH0W BD48 KIOXIA KPM7WRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) VGMCD N/A N/A KIOXIA KPM7XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 6K35K N/A N/A KIOXIA KRM6VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N15JP N/A N/A KIOXIA KRM7VVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 59XF2 N/A N/A SAMSUNG MZILG1T9HCJRAD9 Firmware DUP Storage - 1.92TB SAS SSD (Boot) MFCD7 N/A N/A SAMSUNG MZILS1T9HEJH0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 086DD N/A N/A SAMSUNG MZILT1T9HAJQ0D3 Firmware DUP Storage - 1.92TB SAS SSD (Boot) F0VFY N/A N/A SEAGATE XS1920LE70134 Firmware DUP Storage - 1.92TB SAS SSD (Boot) N6DRV N/A N/A SEAGATE XS1920LE70154 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 91DPV N/A N/A TOSHIBA KPM5XRUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) TDNP7 CPP97 B02A TOSHIBA KPM5XVUG1T92 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 2WVYG CPP97 B02A TOSHIBA PX05SRB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) 0FYFW N/A N/A TOSHIBA PX05SVB192Y Firmware DUP Storage - 1.92TB SAS SSD (Boot) V0K7V N/A N/A WESTERN DIGITAL WUSTVA119BSS200 Firmware DUP Storage - 1.92TB SAS SSD (Boot) 02X38 N/A N/A KIOXIA KRM7VRUG1T92 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) 86XW7 N/A N/A SEAGATE XS1920LE70095 Firmware DUP Storage - 1.92TB vSAS SSD (Boot) K805Y N/A N/A Expander Storage Backplane Firmware DUP Storage - Backplane N/A 60K1J 2.52 uEFI diag Tools-Software Dell 64 Bit uEFI Diagnostics N/A Y5CF5 4301A38
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version Dell EMC PowerSwitch N3248TE-ON MGMT 05WPCH 10.6.0.1 Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.1 Z9100-ON Internal backend N/A 10.6.0.1 Cisco 9348GC-FXP MGMT N/A Minimum supported version:9.3(3) Cisco 93180YC-FX ToR N/A Minimum supported version:9.3(3)
Other Components
Vendor Platform Component Model Firmware Nvidia PowerEdge 640 GPU T4 90.04.96.00.01 Nvidia PowerEdge 840 Dense GPU V100s 88.00.98.00.01 Nvidia PowerEdge 840 Dense GPU Mi25 N/A
SFP Module S3048-ON Platform N3248TE-ON Platform S4048-ON Platform S5048F-ON Platform S5248F-ON Platform 10 GbE SR LC SFP+ X X X X X 10 GbE LR LC SFP+ X X X X X 25 GbE SR LC SFP28+ X X 25 GbE LR LC SFP28+ X X 40 GbE SR BiDi QSFP+ X X X 40 GbE SR MTP/MPO QSFP+ X X X 40 GbE LR MTP/MPO QSFP+ X X X 100 GbE SR MTP/MPO QSFP28+ X X X 100 GbE LR MTP/MPO QSFP28+ X X X 2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version Dell Customer Toolkit AzS_DellEMC_CustomerToolkit_2502.5.zip 2502.5 Dell OEM extension package for drivers and firmware updates AzS-DellEMC-2.4.2502.1.zip 2.4.2502.1 Dell HLH Rebuild to Windows Server 2022 HLH_DataDrive_2502.9_Redeployment.zip 2502.9 Dell Patch and Update Automation Tool Dell_EMC_Patch_and_Update_Automation_QE_2.0.2502.16.exe 2.0.2502.16
1.3.5.2 - Support Matrix for 16G - Dell 2502
Dell Integrated System for Microsoft Azure Stack Hub - Valid from Dell 2502 release and Microsoft 2501 release
Abstract
This support matrix provides information about supported software and hardware configurations for Dell Integrated System for Microsoft Azure Stack Hub.
Introduction
The Dell Integrated System for Microsoft Azure Stack Hub Support Matrix describes supported drivers, firmware, applications, and hardware for Dell Integrated System for Microsoft Azure Stack Hub.
NOTE
All references to release dates refer to Dell Technologies releases, unless otherwise indicated.
16G Scale Units - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox Chipset driver for 16G Intel platforms Driver DUP Chipset N/A P7PJM 10.1.19928.8615 Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 G6M58 24.04.03 HBA355i Driver DUP Storage - HBA K6MCJ M2P63 2.61.48.00 BIOS Firmware DUP BIOS N/A K77XK 2.5.4 BOSS-N1 Firmware DUP BOSS-N1 2MFVD 33TD2 2.1.13.2033 CPLD Firmware DUP CPLD N/A 503F0 1.2.6 iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 5MXXN 7.20.10.50 Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.10.00 PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48 MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D 7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48 7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48 PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A 7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A 7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61 Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1 NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A WR74F 3.32 HBA355i Firmware DUP Storage - HBA K6MCJ Y99R5 24.15.14.00
16G Hardware Lifecycle Host - AS-760
Component Type Category Dell Part Number (P/N) Software Bundle (SWB) Supported Version BOSS-N1 Driver DUP BOSS-N1 2MFVD N/A Inbox Chipset driver for 16G Intel platforms Driver DUP Chipset N/A P7PJM 10.1.19928.8615 Nvidia ConnectX-6 Lx Driver DUP Network/RDMA R5WK9 G6M58 24.04.03 PERC H355 Adapter Driver DUP Storage - HBA VCV6T WC00M 7.726.01.0 BIOS Firmware DUP BIOS N/A K77XK 2.5.4 BOSS-N1 Firmware DUP BOSS-N1 2MFVD 33TD2 2.1.13.2033 CPLD Firmware DUP CPLD N/A 503F0 1.2.6 iDRAC9 with Lifecycle Controller Firmware DUP iDRAC with Lifecycle Controller N/A 5MXXN 7.20.10.50 Nvidia ConnectX-6 Lx Firmware DUP Network/RDMA R5WK9 1H4PM 26.41.10.00 PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 1.92TB SAS SSD VRTN9 NGPR2 BA48 MG07, HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 12TB SAS HDD DK7C9 NFFHM EI0D 7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD FRHHG N/A N/A Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD TY3M5 N/A N/A CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD MXM95 N/A N/A CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 97GR0 N/A N/A CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD XFNX0 N/A N/A PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 15TVC N/A N/A PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD V69W3 N/A N/A PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 617H6 N/A N/A PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 3.2TB NVMe SSD 9VWPD N/A N/A Kioxia KPM6XRUG3T84 Firmware DUP Storage - 3.84TB SAS SSD 2XVX2 N/A N/A PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 3.84TB SAS SSD
9N32F N/A N/A PM6 3WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, SED FIPS Firmware DUP Storage - 3.84TB SAS SSD MD4YN 6DH0W BD48 7450 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD D3GCR N/A N/A Arbordale Plus RR (P5620) SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 5WCR8 N/A N/A CD8 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 23VJP N/A N/A CM6 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD K916X N/A N/A CM7 DP 3WPD, SSD, Gen5 NVMe, 2.5 15mm, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 8RJJ9 N/A N/A PM1725b SP 3WPD, SSD, Gen3 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 08NMX N/A N/A PM1735 V2 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD H8D5M N/A N/A PM1735a SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD 9F6Y3 N/A N/A PMPM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE Firmware DUP Storage - 6.4TB NVMe SSD F6V5P N/A N/A PS1030 SP 3WPD, SSD, Gen4 NVMe, 2.5 15mm, 512e, IS Firmware DUP Storage - 6.4TB NVMe SSD PYMY6 N/A N/A PM1653 1WPD, SSD, 24Gbps SAS, 2.5, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD Y8H7M N/A N/A PM6 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD YM0T1 NGPR2 BA48 PM7 1WPD, SSD, 24Gbps SAS, 2.5 15mm, 512e, ISE Firmware DUP Storage - 7.68TB SAS SSD 7N1WT N/A N/A Cimarron (Exos 7E8), HDD, 12Gbps SAS, 3.5, 7.2K, 512e, ISE Firmware DUP Storage - 8TB SAS HDD 0N660 N/A N/A 7400 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PRV6C N/A N/A 7450 SP 1WPD, SSD, Gen4 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD PH7J6 N/A N/A PE8010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD 21GXV N/A N/A PE9010 SP 1WPD, SSD, Gen3 NVMe, M.2 22x80, 512e, ISE (Boot) Firmware DUP Storage - 960GB NVMe SSD XN5KG N/A N/A Expander Storage Backplane Firmware DUP Storage - Backplane N/A J9JW2 1.61 Non-expander Storage Backplane Firmware DUP Storage - Backplane N/A GXH37 7.1 NVMe Switch Storage Backplane Firmware DUP Storage - Backplane N/A WR74F 3.32 PERC H355 Adapter Firmware DUP Storage - HBA VCV6T RRR7N 52.26.0-5179
Switches
Platform Type Dell Part Number (P/N) Supported Switch OS Version Dell EMC PowerSwitch S5248F-ON ToR N/A 10.6.0.1
Other Components
Vendor Platform Component Model Firmware Nvidia PowerEdge 760 GPU L40S 95.02.66.00.02
SFP Module S5248F-ON Platform 10 GbE SR LC SFP+ X 10 GbE LR LC SFP+ X 25 GbE SR LC SFP28+ X 25 GbE LR LC SFP28+ X 40 GbE SR BiDi QSFP+ X 40 GbE SR MTP/MPO QSFP+ X 40 GbE LR MTP/MPO QSFP+ X 100 GbE SR MTP/MPO QSFP28+ X 100 GbE LR MTP/MPO QSFP28+ X 2x100BASE-2CR4 QSFP28-DD X
Component File Name Supported Version Dell Integrated Systems for Microsoft Azure Stack Hub OEM extension package with drivers and firmware updates AzSHub_16G_Dell2502.3_OEMPackage.zip 2502.3 Dell Integrated Systems for Microsoft Azure Stack Hub HLH ISO MS2406_Dell2502.5.iso 2502.5 Dell Integrated Systems for Microsoft Azure Stack Hub Lifecycle Manager AzSHub_Dell2502.32_LifecycleManager.zip 2502.32
1.4 - Node Expansion
1.4.1 - Node Expansion for 16G
Introduction
This document will guide users through how to add one or more scale unit nodes to their Dell Integrated System for Microsoft Azure Stack Hub that is fully installed and operational.
For the official Microsoft documentation on node expansion, see Add scale unit nodes - Azure Stack Hub .
Solution overview
The only way to increase the capacity of an Azure Stack Hub integrated system is to add more physical computers to the existing scale unit. The scale unit is a collection of physical computers that work together to provide compute, storage, and networking resources. Each physical computer in the scale unit is referred to as a scale unit node.
In order to add a scale unit node, you will need to physically rack, stack, and cable the new node(s), configure Top-of-Rack (ToR) switches, ensure firmware and BIOS configuration match the existing nodes, and add the new node(s) to the Azure Stack Hub integrated system via the Azure Stack Hub administrator portal. This document will guide you through this process.
NOTE
A single scale unit can support up to 16 nodes. You can add scale unit nodes to a scale unit until it reaches its maximum capacity.
Audience
This node expansion guide is for Azure Stack Hub 16th-generation (16G) operators and the Dell Customer Service team who intend to add scale unit nodes to an existing Azure Stack Hub integrated system.
End-to-end deployment workflow
Node expansion workflow
Prerequisites
Ensure the following before you can add a node:
Administrator access to the Azure Stack Hub integrated system.
The rack and the power distribution unit (PDU) must be able to accommodate the new nodes.
New scale unit (SU) nodes must use the same hardware configuration as the existing Azure Stack Hub scale unit nodes.
The Azure Stack Hub integrated system must have the most current Microsoft and Dell Technologies patches and updates. If it does not, update it with the most recent patches and update versions before starting the node expansion process.
The Azure Stack Hub integrated system must be healthy. Check the health state by logging in to the Azure Stack Hub administrator portal. Any active health alerts must be resolved before adding a scale unit node.
Rack, stack, and cable physical nodes
After the new scale unit node or nodes arrive at the customer site, on-site engineers must perform the manual process to rack, stack, and cable the new node(s).
Refer to the following diagrams for Top-of-Rack (ToR) switches cabling guidance.
Scale unit node to ToR-1 network cabling
Scale unit node to ToR-2 network cabling
Scale unit node to ToR-1 iDRAC cabling
Scale unit node to ToR-2 iDRAC cabling
Check Component Readiness
After the new scale unit node or nodes are racked and cabled, power on the new node or nodes and check the LED indicator lights to ensure that all power supply and network cables are connected. See steps below on checking power readiness and checking network fabric connectivity before proceeding with a scale unit node expansion.
Check Power Readiness
To check power readiness, perform the following steps:
Steps
Use a separate power bus for each power distribution unit (PDU).
Ensure that the PDUs are firmly connected to the applicable power sources.
Ensure that the PDUs are powered on.
All servers and switches are equipped with dual power supplies. Ensure that these power supplies are connected to separate PDUs to ensure power redundancy.
Checking network fabric connectivity
Ensure that the new and existing scale unit nodes are connected to the ToR switches.
The odd numbered nodes iDRAC (OoB) port connects to the ToR-1 switch.
The even numbered nodes iDRAC (OoB) port connects to the ToR-2 switch.
The Slot 6 Port 1 port is connected to the ToR-1 switch.
The Slot 6 Port 2 port is connected to the ToR-2 switch.
The following figure shows the port locations for an AS-760 server.
Port Locations for AS-760
S5248F-ON ToR-1 port map
The following table lists the Slot 6 Port 1 connections, cable types, node ports, and switch ports to the S5248F-ON ToR-1 switch.
Origin
Destination
Cable Type
ToR-1 Port 1
Slot 6 Port 1 on Node 1 (AS-760)
25 GbE Twinax
ToR-1 Port 2
Slot 6 Port 1 on Node 2 (AS-760)
25 GbE Twinax
ToR-1 Port 3
Slot 6 Port 1 on Node 3 (AS-760)
25 GbE Twinax
ToR-1 Port 4
Slot 6 Port 1 on Node 4 (AS-760)
25 GbE Twinax
ToR-1 Port 5
Slot 6 Port 1 on Node 5 (AS-760)
25 GbE Twinax
ToR-1 Port 6
Slot 6 Port 1 on Node 6 (AS-760)
25 GbE Twinax
ToR-1 Port 7
Slot 6 Port 1 on Node 7 (AS-760)
25 GbE Twinax
ToR-1 Port 8
Slot 6 Port 1 on Node 8 (AS-760)
25 GbE Twinax
ToR-1 Port 9
Slot 6 Port 1 on Node 9 (AS-760)
25 GbE Twinax
ToR-1 Port 10
Slot 6 Port 1 on Node 10 (AS-760)
25 GbE Twinax
ToR-1 Port 11
Slot 6 Port 1 on Node 11 (AS-760)
25 GbE Twinax
ToR-1 Port 12
Slot 6 Port 1 on Node 12 (AS-760)
25 GbE Twinax
ToR-1 Port 13
Slot 6 Port 1 on Node 13 (AS-760)
25 GbE Twinax
ToR-1 Port 14
Slot 6 Port 1 on Node 14 (AS-760)
25 GbE Twinax
ToR-1 Port 15
Slot 6 Port 1 on Node 15 (AS-760)
25 GbE Twinax
ToR-1 Port 16
Slot 6 Port 1 on Node 16 (AS-760)
25 GbE Twinax
The following table lists the iDRAC connections, cable types, node ports, and switch ports to the S5248F-ON ToR-1 switch.
Origin
Destination
Cable Type
ToR-1 Port 25
iDRAC on Node 1 (AS-760)
1GbE Cat-6
ToR-1 Port 26
iDRAC on Node 3 (AS-760)
1GbE Cat-6
ToR-1 Port 27
iDRAC on Node 5 (AS-760)
1GbE Cat-6
ToR-1 Port 28
iDRAC on Node 7 (AS-760)
1GbE Cat-6
ToR-1 Port 29
iDRAC on Node 9 (AS-760)
1GbE Cat-6
ToR-1 Port 30
iDRAC on Node 11 (AS-760)
1GbE Cat-6
ToR-1 Port 31
iDRAC on Node 13 (AS-760)
1GbE Cat-6
ToR-1 Port 32
iDRAC on Node 15 (AS-760)
1GbE Cat-6
S5248F-ON ToR-2 port map
The following table lists the Slot 6 Port 2 connections, cable types, node ports, and switch ports to the S5248F-ON ToR-2 switch.
Origin
Destination
Cable Type
ToR-2 Port 1
Slot 6 Port 2 on Node 1 (AS-760)
25 GbE Twinax
ToR-2 Port 2
Slot 6 Port 2 on Node 2 (AS-760)
25 GbE Twinax
ToR-2 Port 3
Slot 6 Port 2 on Node 3 (AS-760)
25 GbE Twinax
ToR-2 Port 4
Slot 6 Port 2 on Node 4 (AS-760)
25 GbE Twinax
ToR-2 Port 5
Slot 6 Port 2 on Node 5 (AS-760)
25 GbE Twinax
ToR-2 Port 6
Slot 6 Port 2 on Node 6 (AS-760)
25 GbE Twinax
ToR-2 Port 7
Slot 6 Port 2 on Node 7 (AS-760)
25 GbE Twinax
ToR-2 Port 8
Slot 6 Port 2 on Node 8 (AS-760)
25 GbE Twinax
ToR-2 Port 9
Slot 6 Port 2 on Node 9 (AS-760)
25 GbE Twinax
ToR-2 Port 10
Slot 6 Port 2 on Node 10 (AS-760)
25 GbE Twinax
ToR-2 Port 11
Slot 6 Port 2 on Node 11 (AS-760)
25 GbE Twinax
ToR-2 Port 12
Slot 6 Port 2 on Node 12 (AS-760)
25 GbE Twinax
ToR-2 Port 13
Slot 6 Port 2 on Node 13 (AS-760)
25 GbE Twinax
ToR-2 Port 14
Slot 6 Port 2 on Node 14 (AS-760)
25 GbE Twinax
ToR-2 Port 15
Slot 6 Port 2 on Node 15 (AS-760)
25 GbE Twinax
ToR-2 Port 16
Slot 6 Port 2 on Node 16 (AS-760)
25 GbE Twinax
The following table lists the iDRAC connections, cable types, node ports, and switch ports to the S5248F-ON ToR-2 switch.
Origin
Destination
Cable Type
ToR-2 Port 25
iDRAC on Node 2 (AS-760)
1GbE Cat-6
ToR-2 Port 26
iDRAC on Node 4 (AS-760)
1GbE Cat-6
ToR-2 Port 27
iDRAC on Node 6 (AS-760)
1GbE Cat-6
ToR-2 Port 28
iDRAC on Node 8 (AS-760)
1GbE Cat-6
ToR-2 Port 29
iDRAC on Node 10 (AS-760)
1GbE Cat-6
ToR-2 Port 30
iDRAC on Node 12 (AS-760)
1GbE Cat-6
ToR-2 Port 31
iDRAC on Node 14 (AS-760)
1GbE Cat-6
ToR-2 Port 32
iDRAC on Node 16 (AS-760)
1GbE Cat-6
Using a crash cart with a serial connection or an SSH connection to the ToR switches, ensure that all ports that have a new node connected have been configured correctly.
To configure the ToR switches, perform the following steps:
Steps
Log in to the S5248F-ON ToR-1 switch
Once logged in type the commands below to configure the data link connections to the newly added scale unit nodes. For example, if wishing to expand a four-node scale unit with additional four nodes, you would run the below on the switch:
conf t
interface range ethernet 1/1/5-1/1/8
description "CL01 Nodes NIC"
no shutdown
switchport mode trunk
switchport access vlan 7
switchport trunk allowed vlan 107
mtu 9216
flowcontrol receive off
priority-flow-control mode on
service-policy input type network-qos AZS_SERVICES_pfc
service-policy output type queuing AZS_SERVICES_ets
ets mode on
qos-map traffic-class AZS_SERVICES_Que
spanning-tree bpduguard enable
spanning-tree guard root
spanning-tree port type edge
exit
Once the data link port or ports are configured on the switch proceed to configuring the BMC Management ports. For example, if wishing to expand a four-node scale unit with an additional four nodes, you would run the below on the switch:
conf t
interface range ethernet 1/1/27:1-1/1/28:1
description "BMCMgmt Ports"
no shutdown
switchport access vlan 125
mtu 9216
flowcontrol receive off
spanning-tree bpduguard enable
spanning-tree guard root
end
Once the BMC Management port or ports have been configured you will need to run the command below to write the new configuration into memory on the switch:
copy running-configuration startup-configuration
Once you have completed steps 1-4, repeat them on the ToR-2 switch.
Accessing the iDRAC Direct port
The iDRAC Direct port is a USB port located on the front of the server and is used to access the iDRAC web interface, RACADM, and Redfish API, without needing to connect to the network.
NOTE
The factory default defined iDRAC administrator credential username will be azsinstall and the password will be azsinstall . This credential will be rotated as part of the node expansion process.
To access the iDRAC Direct port, perform the following steps:
Steps
To access the iDRAC Direct port, you must connect a USB Type A to micro-USB cable from a laptop or mobile KVM host to the micro-USB port on the front of the server.
From your host, turn off any wireless networks and disconnect from any other hard-wired networks.
Connect a USB Type A to micro-USB cable from your host to the iDRAC Direct micro-USB port located on the front control panel of the AS-760 server.
AS-760 front view with iDRAC Direct port highlighted
Wait for the host to acquire an IP address of 169.254.0.4 . It may take several seconds for the IP address to be acquired. The iDRAC will acquire an IP address of 169.254.0.3 .
Open a web browser and provide the iDRAC Direct port IP address as the URL. For example, https:// 169.254.0.3 .
At the certificate warning window, click Advanced and then click Proceed to 169.254.0.3 (unsafe) .
Certificate warning window
Enter the factory default username and password for the iDRAC, and click Log In .
iDRAC 9 login screen
Assigning iDRAC IP addresses to the new scale unit nodes for expansion
The iDRAC IP address assignment is a manual step. The iDRAC Direct port can be leveraged on the node(s) to assign the iDRAC IP addresses based on the assigned BMC management (BMCMgmt) network IP address from the Azure Stack Hub deployment worksheet.
To manually assign the iDRAC IP addresses to the new scale unit nodes for expansion, perform the following steps:
Steps
The below steps will be repeated for each new scale unit node to be added.
Follow the steps previously mentioned on Accessing the iDRAC Direct port .
From the iDRAC dashboard, browse to iDRAC Settings > Connectivity and expand the Network > IPv4 Settings menu.
iDRAC Settings > Network > IPv4 Settings menu
Set the static IP address, static gateway, and static subnet mask according to the values defined in the Azure Stack Hub deployment worksheet. These IP addresses are defined by the BMCMgmt /26 subnet provided to the deployment worksheet.
Azure Stack Hub deployment worksheet BMCMgmt network
Click Apply .
Prior to running the node expansion script, it is important to perform a quick health check of the new node(s). This also allows the iDRAC to perform an inventory collection which is needed for the firmware upgrade automation to successfully validate the new node(s).
To perform a health check on the new nodes for expansion, perform the following steps:
Steps
The below steps will be repeated for each new scale unit node to be added.
If the new node(s) are powered off, press the power button to boot the new node(s).
Allow up to 10 minutes for the new node(s) to fully load BIOS settings and complete the BIOS initialization.
Once complete, access the iDRAC web interface either via the iDRAC Direct port or by leveraging a remote desktop (RDP) connection from the Hardware Lifecycle Host (HLH).
Verify there are no alerts or warnings on the dashboard.
Navigate to System > Overview > Network Devices and verify that NIC Slot 6 shows both ports with a Link Status of Up .
Navigate to Storage > Overview > Physical Disks and verify all drives are present and healthy.
Navigate to Storage > Overview > Virtual Disks and verify a virtual disk is present.
Once complete, navigate back to the Dashboard and power off the node.
Update firmware on new scale unit nodes
This section covers updating firmware on scale unit node(s).
WARNING
To maintain the integrity of Dell Azure Stack Hub Integrated System before adding any new scale unit nodes, you must first follow the Patch and Update guide which includes Lifecycle Manager, ToR switch firmware updates, and OEM package updates.
This will ensure that any new scale unit nodes have the correct firmware and BIOS configuration applied when they are added to the cluster.
Node expansion script
The node expansion script is used to update firmware and apply BIOS configuration on the new scale unit node(s) before they are added to the Azure Stack Hub integrated system.
The script will also update the DeploymentData JSON file with the new scale unit node(s) information.
The script will not add the new scale unit node(s) to the Azure Stack Hub integrated system, see the Add scale unit node in the Azure Stack Hub administrator portal section for more information on how to add the new scale unit node(s) to the Azure Stack Hub integrated system.
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager contains the node expansion script, Invoke-DellAzSHubNodeExpansion.ps1 . After completing the Patch and Update process, you should have the latest Lifecycle Manager available in E:\LCM .
WARNING
Ensure that the new scale unit node(s) are powered off before running the Invoke-DellAzSHubNodeExpansion.ps1 script, otherwise the script will fail.
NOTE
The factory default defined iDRAC administrator credential username is azsinstall and the password is azsinstall .
To run the node expansion script, perform the following steps:
Steps
From the HLH, open a PowerShell console window as an administrator.
Before running the node expansion script, make sure you have the following information:
Number of nodes being added
Factory BMC user credentials
BMC administrator credentials
HLH administrator credentials
Change the directory to E:\LCM
Set-Location -Path E:\LCM
Run the following command to start the expansion process. Change the “X” to the number of nodes that are being added.
.\Invoke-DellAzSHubNodeExpansion.ps1 -AdditionalNodeCount X
You will be prompted to input the BMC user, BMC administrator and HLH administrator credentials before the upgrade begins.
The automation will run the firmware update process one node at a time . Each node will take about an hour to complete.
Once the firmware update process is complete on all nodes your prompt will look as shown below. The new nodes have now been added to the DeploymentData JSON file and are ready to be added to the cluster from the Azure Stack Hub administrator portal:
(...)
VERBOSE: 20250214-225038:Invoke-FirmwarePostUpdate:Invoke-OEMFirmwarePostUpdate completed successfully.
VERBOSE: 20250214-225038:Remove-AutoLogon:Removing auto admin logon.
VERBOSE: 20250214-225038:Resume-HLHBitLocker:Importing BitLocker module.
VERBOSE: 20250214-225038:Resume-HLHBitLocker:Getting BitLocker encrypted volumes.
VERBOSE: 20250214-225039:Resume-HLHBitLocker:Restoring TPM protector on volume 'D:'.
VERBOSE: 20250214-225039:Disable-DHCPServer:Disabling DHCP server service.
VERBOSE: 20250214-225039:Invoke-OEMFirmwareBootstrap:PROGRESS - Cleanup complete.
VERBOSE: 20250214-225039:Invoke-OEMFirmwareBootstrap:PROGRESS - Invoke-OEMFirmwareBootstrap completed successfully.
Finished running Invoke-FirmwareBootstrap for sac42-S1-N08 - 10.128.164.74 with Deployment Data JSON: E:\AzureStack\DeploymentData_new_one.json
> List of nodes in the Deployment Data JSON: 'E:\AzureStack\DeploymentData_new_one.json'.
Name BMCIPAddress
---- ------------
sac42-S1-N01 10.128.164.67
sac42-S1-N02 10.128.164.68
sac42-S1-N03 10.128.164.69
sac42-S1-N04 10.128.164.70
sac42-S1-N05 10.128.164.71
sac42-S1-N06 10.128.164.72
sac42-S1-N07 10.128.164.73
sac42-S1-N08 10.128.164.74
(...)
> Successfully replaced the original Deployment Data JSON with the new one.
Locate Logs
To locate the logs from the node expansion script, perform the following steps:
Steps
From the HLH, open File Explorer and navigate to the C:\MASLogs folder.
The logs that were generated from the node expansion script will have the filename: OEMFirmwareUpdate_[date]-[time] .
Add scale unit node in the Azure Stack Hub administrator portal
The operation to add a scale unit node consists of two distinct phases: compute and storage .
The compute expansion process can take between 1-3 hours to complete per scale unit node. The storage expansion process can take several days to complete, depending on the size of the storage pool and the number of scale unit nodes being added.
NOTE
To perform any tasks within the Azure Stack Hub administrator portal, you must have the necessary administrator privileges to the Default Provider Subscription .
Before adding a scale unit node within the Azure Stack Hub administrator portal, ensure that you have completed all the steps below:
WARNING
While an add scale unit node operation is already in progress do not attempt any of the following operations:
Stop Azure Stack Hub
Update Azure Stack Hub
Repair/FRU scale unit node
Certificates rotation
Add another scale unit node (the previous add scale unit node operation failure is also considered in progress)
Steps
WARNING
Only one scale unit node can be added at a time during the compute expansion process. Once one scale unit node has been successfully added to the cluster, you can proceed with adding the next scale unit node.
Log into the Azure Stack Hub administrator portal as an Azure Stack Hub administrator.
Browse to All services > Region management > Scale units > [Cluster name] > Nodes .
Click the Add node button.
The Region and the Scale unit will be populated automatically. You will need to specify the BMC IP Address of the scale unit node you are adding.
Once you have entered the IP address of the new scale unit node, click Add at the bottom of the screen.
NOTE
The add node operation first adds the new scale unit node as available compute capacity and then automatically extends the storage capacity.
It will take a few minutes for the new scale unit node to be visible in the Azure Stack Hub administrator portal.
The new scale unit node will be in a Adding state until the compute expansion process is complete.
Click the notifications in the upper right to check the status as shown below:
Once the scale unit node expansion compute process is complete, your notifications will show as the following:
CAUTION
After a scale unit node is added, the storage expansion process begins and can run for multiple days before it completes the expansion.
In order to check the status of the storage expansion provisioning task you can navigate to All services > Region management > Scale units . Once here, you will see the status as Configuring Storage if the storage expansion provisioning task is not yet complete. When this task is complete the status will change to Running .
NOTE
You do not need to wait for the Configuring Storage task to complete before adding the next scale unit node.
There is no impact to the running workloads while another scale unit node is being added.
1.5 - Patch and Update
1.5.1 - Patch and Update for 16G
Introduction
Microsoft Azure Stack Hub operators are faced with the enormous challenge of keeping their solution both secure and functional. They must ensure that the solution is not vulnerable to threats, external or internal, while maintaining negotiated service-level agreements.
Solution overview
As a Microsoft Azure Stack Hub systems provider, Dell Technologies is committed to ensuring that your Azure Stack Hub environment is both secure and functional. In Dell Technologies releases, you will find firmware and driver updates for both the Hardware Lifecycle Host (HLH) and the scale unit (SU) nodes that are contained in the OEM package updates. Dell Technologies delivers these updates quarterly, and you can apply them independently of Microsoft updates.
There are two other types of update packages for the Azure Stack Hub integrated systems: software updates and hotfixes .
For more information, see Update package types - Azure Stack Hub .
Audience
This patch and update guide is for Azure Stack Hub 16th-generation (16G) operators who intend to perform lifecycle operations (Patch and Update) for:
Firmware updates for the Hardware Lifecycle Host (HLH)
Operating System updates for the HLH (Windows Server 2022)
Driver updates for the HLH (Windows Server 2022)
Windows Defender Application Control (WDAC) policy updates for the HLH Operating System
Firmware updates for the Top-of-Rack (ToR) switches (S5248F-ON)
Firmware updates for the scale unit (SU) nodes
Driver updates for the scale unit nodes (Windows Server 2022)
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager overview
Dell Integrated System for Microsoft Azure Stack Hub Lifecycle Manager provides an automated way of upgrading HLH firmware, software, and driver components.
Lifecycle Manager will perform the following tasks:
Update firmware on the Hardware Lifecycle Host
Update drivers on the Hardware Lifecycle Host
Install Windows updates for the Hardware Lifecycle Host Operating System
Update the Windows Defender Application Control (WDAC) policy on the Hardware Lifecycle Host
NOTE
Firmware updates for the Top-of-Rack (ToR) switches are not included in the Lifecycle Manager update process and must be updated manually from the Hardware Lifecycle Host (HLH) using SCP and SSH commands. See the section Manually Updating the Switch Firmware from the Hardware Lifecycle Host (HLH) for more information.
Firmware and driver updates for scale unit (SU) nodes are not included in the Lifecycle Manager update process and must be updated manually using the Azure Stack Hub administrator portal. See the section OEM package updates for more information.
Lifecycle Manager should take between 1-2 hours to complete.
Lifecycle Manager is available for download on the Integrated System for Microsoft Azure Stack Hub 16G > Drivers & Downloads product support website.
OEM package updates
The Azure Stack Hub OEM package update contains firmware, device drivers, and hardware management tools in a specialized format used by Azure Stack Hub during initial deployment and update.
Dell Technologies is responsible for the end-to-end servicing lifecycle for the hardware-related firmware and driver update packages.
In addition, Dell Technologies will own and maintain guidance for all software and hardware on the HLH.
OEM package updates are available for download on the Integrated System for Microsoft Azure Stack Hub 16G > Drivers & Downloads product support website.
Prerequisites
Perform the following steps before proceeding with the Lifecycle Manager update process. There are some steps which are a one-time-activity and some that you must perform in every release.
Download the Lifecycle Manager zip file
To download the latest Lifecycle Manager zip file, perform the following steps:
Steps
Go to the Dell Technologies Support website at Integrated System for Microsoft Azure Stack Hub 16G > Drivers & Downloads and download the latest Lifecycle Manager zip file.
Log in to the HLH with the HLHAdmin default administrator account or a customer specified administrative user account.
On the HLH, navigate to the E:\ drive and create a folder named Temp .
Download the Lifecycle Manager zip file to the HLH E:\Temp directory.
Download the OEM Update Package zip file
To download the corresponding OEM package update zip file, perform the following steps:
Steps
Go to the Dell Technologies Support website at Integrated System for Microsoft Azure Stack Hub 16G > Drivers & Downloads and download the latest OEM package update zip file.
WARNING
The Lifecycle Manager zip file version must match the version of the OEM package zip file, otherwise the Lifecycle Manager will not pass the pre-checks.
For example, if the Lifecycle Manager zip file is 2502 , then the OEM package zip file must also be 2502 .
Log in to the HLH with the HLHAdmin default administrator account or a customer specified administrative user account.
Download the OEM package update zip file to the HLH E:\Temp directory.
Extract Lifecycle Manager and OEM package update zip files
Lifecycle Manager zip and OEM package update zip files that were downloaded to the HLH from the Dell support website will need to be extracted into their own directories.
To extract Lifecycle Manager and OEM package update zip files, perform the following steps:
Steps
Before beginning the extraction process, first the files in the E:\Temp directory will need to be unblocked. Open a PowerShell terminal as administrator and type the following command:
Get-ChildItem -Path "E:\Temp" -Recurse | Unblock-File
WARNING
Lifecycle Manager zip file contents must be unblocked ; otherwise, the Lifecycle Manager will not pass the pre-checks.
Once the contents within the E:\Temp directory have been unblocked, you can begin to extract the zip files into their directories.
On the HLH, navigate to the E:\ drive and create a folder named LCM .
On the HLH, navigate to the E:\ drive and create a folder named OEM .
Extract the Lifecycle Manager zip file from the E:\Temp directory to the E:\LCM directory.
Extract the OEM package update zip file from the E:\Temp directory to the E:\OEM directory.
Hardware Lifecycle Host (HLH)
Running Lifecycle Manager
NOTE
Lifecycle Manager will reboot the HLH multiple times during the upgrade process. You will need to log back into the HLH manually after each reboot; otherwise, the upgrade will not continue until you do.
As an optional step you can enable the Auto Logon feature on the HLH. This will allow the HLH to automatically log back in after each reboot.
For more information on how to enable the Auto Logon feature, see Turn on automatic logon in Windows .
To run Lifecycle Manager on the HLH, perform the following steps:
Steps
WARNING
Never use PowerShell ISE at any time during the use of this document.
From the HLH, open a PowerShell console window as an administrator.
You will need to export the BitLocker recovery keys before proceeding with the upgrade. Type the command below into your PowerShell prompt to export your BitLocker recovery keys.
(Get-BitLockerVolume -MountPoint D, E).KeyProtector | Where-Object -FilterScript {$_.KeyProtectorType -eq 'RecoveryPassword'} | Select-Object -Property KeyProtectorId,RecoveryPassword | Out-File -FilePath "E:\Temp\BitLockerRecoveryKeys.txt"
CAUTION
Once the BitLocker recovery keys have been exported into the E:\Temp folder, ensure they are moved to a secure location outside of the HLH.
Failure to do so may result in an inaccessible HLH due to firmware or hardware issues during the firmware upgrade process.
For more information see BitLocker Operations Guide .
Change the current directory to the E:\LCM location that the Lifecycle Manager zip file was extracted to in a previous step:
Set-Location -Path "E:\LCM"
Run Lifecycle Manager by using the following command:
.\Invoke-DellAzSHubLifecyclemanager.ps1 -OEMPackagePath "E:\OEM\AzS-Dell-<version>.zip"
You will be prompted to provide credentials for the following endpoints:
Hardware Lifecycle Host OS administrative account credential
iDRAC administrative account credential for the Hardware Lifecycle Host
You will then be prompted to confirm that you have backed up the BitLocker recovery keys. Press Y to confirm if you have backed up the BitLocker recovery keys; otherwise, press N to cancel the update process and back up your BitLocker recovery keys.
Once the update process begins, continue to monitor Lifecycle Manager while it runs. While the automation is running there will be multiple reboots, in order to keep the upgrade process progressing you must log back into the HLH manually; otherwise, the upgrade will not continue until you do .
Some updates are grouped together to limit the amount of reboots. The HLH may reboot for any of the following reasons:
Update Type
Reboot Type
Firmware updates
Separate reboot
Driver updates
Grouped reboot
Operating System updates
Grouped reboot
Windows Defender Application Control (WDAC) policy updates
Grouped reboot
Upon completion, the output should look similar to the image shown below. This shows a list of all completed tasks from Lifecycle Manager, as well as the total elapsed time of the upgrade.
If the upgrade was successful, you will see the Dell AzS Hub Lifecycle Manager completed successfully message in the output.
Finally, you can gather logs by navigating to the directory E:\LCM\Logs on the HLH. These logs can be used for troubleshooting purposes if needed.
Additionally, C:\MASLogs will contain logs related to the firmware update process.
Top-of-Rack (ToR) Switches
Manually Updating the Switch Firmware from the Hardware Lifecycle Host (HLH)
You must manually install the OS10 software image from the HLH using SCP and SSH commands.
WARNING
To maintain the integrity of Dell Azure Stack Hub Integrated System, it is required to perform the switch firmware update in conjunction with the Lifecycle Manager update process.
To update switch firmware, perform the following steps:
Steps
WARNING
Never use PowerShell ISE at any time during the use of this document.
From the HLH, open a PowerShell console window as an administrator.
The HLH can be accessed via Remote Desktop Protocol (RDP) from a Permitted Network .
Change directory to E:\OEM\AzS-Dell -<version> \Firmware\Switches\msftdell
Set-Location -Path "E:\OEM\AzS-Dell-<version>\Firmware\Switches\msftdell"
Run the following command to copy the switch firmware from the extracted OEM package update zip file on the HLH to the ToR switches.
For example, if upgrading the firmware on ToR-1 with an IP address of 10.128.164.98 and a switch administrative user account of azsadmin-gtbzp , you would run the following:
scp -o MACs=hmac-sha2-512 .\PKGS_OS10-Enterprise-<version>-installer-x86_64.bin azsadmin-gtbzp@10.128.164.98:
Repeat the above step for ToR-2.
For example, if upgrading the firmware on ToR-2 with an IP address of 10.128.164.99 and a switch administrative user account of azsadmin-gtbzp , you would run the following:
scp -o MACs=hmac-sha2-512 .\PKGS_OS10-Enterprise-<version>-installer-x86_64.bin azsadmin-gtbzp@10.128.164.99:
The below steps will be repeated on each ToR switch (e.g. ToR-1 and ToR-2) ONLY after fully completing the first switch (e.g. ToR-1).
Run the following commands to connect to the ToR switch.
For example, if upgrading the firmware on ToR-1 with an IP address of 10.128.164.98 and a switch administrative user account of azsadmin-gtbzp , you would run the following:
ssh -o MACs=hmac-sha2-512 azsadmin-gtbzp@10.128.164.98
Enter the password of the switch administrative user account when prompted.
Run the following command to move the SCP copied firmware file to its intended destination (/var/os10-image ):
system "sudo mv ./PKGS_OS10-Enterprise-<version>-installer-x86_64.bin /var/os10-image"
Enter the password of the switch administrative user account when prompted.
Verify the image is now located in the image directory.
dir image
The output should look similar to the below example:
Directory contents for folder:
Date (modified) Size (bytes) Name
--------------------- ------------ ------------------------------------------
2025-03-18T18:37:56+00:667040481 PKGS_OS10-Enterprise-<version>-installer-x86_64.bin
To verify that an installation is not already in progress, run the following command:
show image status
The output should look similar to the below example:
Image Upgrade State: idle
==================================================
File Transfer State: idle
--------------------------------------------------
State Detail: No download information available
Task Start: -001-11-30T00:00:00+00:00
Task End: -001-11-30T00:00:00+00:00
Transfer Progress: 0 %
Transfer Bytes: 0 bytes
File Size: 0 bytes
Transfer Rate: 0 kbps
Installation State: idle
--------------------------------------------------
State Detail: No install information available
Task Start: -001-11-30T00:00:00+00:00
Task End: -001-11-30T00:00:00+00:00
Run the following command to install the downloaded image to the standby partition:
image install image://PKGS_OS10-Enterprise-<version>-installer-x86_64.bin
To view the image install progress, run the following command:
show image status
The output should look similar to the below example:
Image Upgrade State: idle
==================================================
File Transfer State: idle
--------------------------------------------------
State Detail: No download information available
Task Start: 0000-00-00T00:00:00Z
Task End: 0000-00-00T00:00:00Z
Transfer Progress: 0 %
Transfer Bytes: 0 bytes
File Size: 0 bytes
Transfer Rate: 0 kbps
Installation State: install
--------------------------------------------------
State Detail: In progress: Configure filesystem (3 of 9)
Task Start: 2025-03-17T21:15:16Z
Task End: 0000-00-00T00:00:00Z
Keep checking until the image installation is complete. Then check to verify if the image is installed to the standby partition by running the following command:
show boot
The output should look similar to the below example:
Current system image information:
===================================
Type Boot Type Active Standby Next-Boot
-----------------------------------------------------------------------------------
Node-id 1 Flash Boot [B] 10.5.6.5 [A] 10.6.0.1 [B] active
Set the next boot partition to the standby partition where the downloaded image is installed by running the following command:
boot system standby
Save the currently running configuration and then reload to the configured image by running the following commands:
write memory
reload
After the switch reloads, copy the new active image to the standby boot partition by running the following command:
image copy active-to-standby
Verify the status of the BGP connections on the switches by running the following command:
show ip bgp summary
Verify that BGP is established for all neighbors as indicated by the Up/Down column showing a connection timer. The output should look similar to the below example:
BGP router identifier 10.128.164.24 local AS number 64910
Neighbor AS MsgRcvd MsgSent Up/Down State/Pfx
10.128.165.12 64912 11 12 00:07:01 25
10.128.165.13 64912 11 12 00:07:01 25
10.128.165.33 64912 10 10 00:07:01 25
10.128.164.1 64900 11 12 00:07:06 1
10.128.164.9 64900 11 12 00:07:06 1
10.128.164.30 64910 12 14 00:06:23 8
10.128.164.34 64910 12 14 00:07:06 8
Verify that the switch firmware version was updated by running the following command:
show version
The output should look similar to the below example:
Dell SmartFabric OS10 Enterprise
Copyright (c) 1999-2024 by Dell Inc. All Rights Reserved.
OS Version: 10.6.0.1
Build Version: 10.6.0.1.35
Build Time: 2024-12-02T17:55:39+0000
System Type: S5248F-ON
Architecture: x86_64
Up Time: 1 day 00:11:14
Original Equipment Manufacturer (OEM) package updates
Servicing Policy
Updates for the hardware components in the form of driver updates, firmware updates, and security patches are provided by Dell Technologies. These updates are referred to as OEM package updates . It is recommended to be within N-2 of the current available OEM package for Azure Stack Hub.
WARNING
Azure Stack Hub OEM package updates must be installed in sequential order.
It is not supported to skip an OEM package update version.
Identify the OEM version applied to the Azure Stack Hub
To identify the version of the Original Equipment Manufacturer (OEM) package currently applied to the Azure Stack Hub, perform the following steps:
Steps
Open the Azure Stack Hub administrator portal.
Open the Microsoft Azure Stack Hub - Administration Dashboard and click Dashboard .
Click Update .
The Updates blade will appear as shown below. The Updates blade displays your current Azure Stack Hub version and the latest deployed version of the OEM package update.
Import and Install an OEM package update
In this step you will be uploading and installing the OEM package update utilizing the Azure Stack Hub administrator portal.
CAUTION
Before you apply an OEM package update, always apply the latest Azure Stack Hub hotfix available for your Azure Stack Hub system.
For additional information about Azure Stack Hub updates, please see:
Steps
Access the Azure Stack Hub administrator portal of the system you wish to perform the OEM package update on.
Navigate to Storage accounts > updateadminaccount > Containers .
Create a container for the OEM package update by clicking +Container .
In the Name field on the right navigation pane enter the name for your container e.g. 2408oemupdate and then click Create .
Once the container is created, click the name of the container to access it.
Once you have clicked on the container click Upload at the top of the page.
Dell OEM package updates are in a zip format. The zip file contains the oemMetadata.xml file and the OEM package update payload.
You will need to upload both the zip file for the OEM package update and the oemMetadata.xml that is associated with it.
Once uploaded to the storage account container, they should appear in the container that was created in step 3.
Navigate back to the Dashboard and then click the Update tile.
The Updates blade should now show an available OEM package update that can be installed.
Click the update and then click Install to install the OEM package update.
After clicking install on the OEM package update, the update run details can be seen by clicking on the update in the Updates menu once the update has entered into a Preparing or Installing state.
Once completed, Updates blade should display Applied successfully and in the Update history menu the update state should be marked as Installed .
If the update fails, the Update blade reports Needs attention . Click on the failed update and use the Download summary button to get a high-level status of where the update failed.
1.6 - How To
1.6.1 - How to create a service principal name for Azure Stack Hub integrated with Active Directory Federation Services identity using PowerShell
Overview
This article explains how to create a service principal name (SPN) to manage Azure Stack Hub integrated with Active Directory Federation Services (AD FS) identity using PowerShell.
For more information about this process, visit Give an app access to Azure Stack Hub resources .
It will guide you through the creation of:
Prerequisites
Prerequisites from a Windows-based external client are:
Overview of the creation process for Azure Stack Hub SPN
NOTE
The procedure provided is designed for Azure Stack Hub Operators as it requires Privileged Endpoint (PEP) access as well as assumes the Default Provider Subscription and the Administrator Azure Resource Manager endpoint as the defaults; however, the same mechanism can be applied to the User Subscriptions with minimal changes to the code.
If you want to assign a role the SPN for a User Subscription , replace the Administrator Azure Resource Manager endpoint with the Tenant Azure Resource Manager endpoint and the Default Provider Subscription with Subscription Name you want to modify.
Declare your variables accordingly.
Log in to your Azure Stack Hub Default Provider Subscription with administrator user credentials (needs to have the Owner role).
CAUTION
This requires interactive prompt as by default when using AD FS as your identity provider you cannot use user credentials in the non-interactive way.
This is the main reason why you would want to create an SPN so that you can automate your operations.
Create your AD FS application/service principal.
Assign the appropriate Role to your service principal.
NOTE
As a bonus, we include an example of how to assign the Owner role to an AD FS group
The current AzureStack modules do not support it natively, but this example will show you how to do it via API.
It is the preferred method of assigning roles, you should assign roles to a group rather than individual users.
Log in to your Azure Stack Hub Default Provider Subscription using the SPN account.
Verify SPN authentication and the role assignment.
Create Azure Stack Hub SPN
Service Principal credential :
Certificate
Client Secret
Create a PFX Certificate
#region Declare variables
$CertificateName = "ADFSAutomationCert"
$CertStore = "cert:\LocalMachine\My" # This can also be "cert:\CurrentUser\My" but in general service accounts cannot access CurrentUser cert store
$CertSubject = "CN=$CertificateName"
$PfxFilePath = "C:\Temp"
if (-not (Test-Path -Path $PfxFilePath)) {
New-Item -ItemType Directory -Path $PfxFilePath -Force | Out-Null
}
$PfxFilePathFull = Join-Path -Path $PfxFilePath -ChildPath "$($CertificateName).pfx"
$PfxPassword = '""' | ConvertTo-SecureString -AsPlainText -Force # replace "" with an actual password or leave "" for it to be blank
#endregion
#region Create certificate to pass into new Application
$ExpiryDate = (Get-Date).AddDays(365) # You can change this to whatever fits your security profile better, default is 1 year
$Cert = New-SelfSignedCertificate -CertStoreLocation $CertStore -Subject $CertSubject -KeySpec KeyExchange -NotAfter $ExpiryDate
Write-Verbose -Message "Certificate ""$($Cert.Subject)"" with start date ""$($Cert.NotBefore)"" and end date ""$($Cert.NotAfter)"" created at ""$($PfxFilePathFull)""."
#endregion
#region Get a cert object from a .pfx file - you need it to create the SPN to begin with
$Cert = Get-PfxCertificate -FilePath $PfxFilePathFull -Password $PfxPassword
#endregion
#region Optional steps
#region Export the certificate so that you can import it on other environments
try {
Export-PfxCertificate -Cert $Cert.PsPath -FilePath $PfxFilePathFull -Password $PfxPassword -ErrorAction Stop | Out-Null
} catch {
throw "Failed to export certificate to ""$($PfxFilePathFull)"":`n$($_.Exception.Message)"
}
#endregion
#region Import the certificate into the certificate store on another environment
Import-PfxCertificate -CertStoreLocation $CertStore -FilePath $PfxFilePathFull -Password $PfxPassword -Exportable
#endregion
#endregion
Create Azure Stack Hub SPN that uses certificate credential
#region Declare variables
$CertificateName = "ADFSAutomationCert"
$PfxFilePath = "C:\Temp"
$PfxFilePathFull = Join-Path -Path $PfxFilePath -ChildPath "$($CertificateName).pfx"
$PfxPassword = '""' | ConvertTo-SecureString -AsPlainText -Force
$CertificateObject = Get-PfxCertificate -FilePath $PfxFilePathFull -Password $PfxPassword
$CertificateThumbprint = $CertificateObject.Thumbprint
if (!$CertificateThumbprint) {
throw "Failed to obtain a thumbprint from certificate: $($PfxFilePathFull)"
}
$CloudAdminUsername = "CloudAdmin@azurestack.local"
[SecureString]$CloudAdminPassword = ConvertTo-SecureString "Password123!" -AsPlainText -Force
$ApplicationName = "ADFSAppCert"
$AzureStackRole = "Owner"
$ADGroupName = "AzureStackHubOwners"
$AzureStackAdminArmEndpoint = "https://adminmanagement.local.azurestack.external/"
$EnvironmentName = "AzureStackAdmin"
$PepCreds = New-Object -TypeName System.Management.Automation.PSCredential -ArgumentList $CloudAdminUsername, $CloudAdminPassword
$PepIPAddress = "x.x.x.224" # e.g. 10.5.30.224
#endregion
#region Register and set an Az environment that targets your Azure Stack Hub instance
Write-Output -InputObject "Connecting to Azure Stack Hub Admin Management Endpoint - $(AzureStackAdminArmEndpoint)"
$null = Add-AzEnvironment -Name $EnvironmentName -ARMEndpoint $AzureStackAdminArmEndpoint
$null = Connect-AzAccount -Environment $EnvironmentName -UseDeviceAuthentication # Interactive prompt
if (((Get-AzContext).Subscription).Name -notlike "Default Provider Subscription") {
throw "Failed to obtain access to the 'Default Provider Subscription'. Please verify the user has been assigned the '$($AzureStackRole)' role for the 'Default Provider Subscription'."
}
#endregion
#region Create a PSSession to the Privileged Endpoint VM
Write-Output -InputObject "Create a PowerShell Session to the Privileged Endpoint VM"
$PepSession = New-PSSession -ComputerName $PepIPAddress -ConfigurationName PrivilegedEndpoint -Credential $PepCreds -SessionOption (New-PSSessionOption -Culture en-US -UICulture en-US)
#endregion
#region Check for existing SPN
Write-Output -InputObject "Check for existing SPN '$($ApplicationName)'"
$SPNObjectCheckJob = Invoke-Command -Session $PepSession -ScriptBlock { Get-GraphApplication } -AsJob | Wait-Job
if ($SPNObjectCheckJob.State -ne "Completed") {
throw "$($SPNObjectCheckJob.ChildJobs | Receive-Job)"
}
$SPNObjectCheck = $SPNObjectCheckJob.ChildJobs.Output | Where-Object { $_.Name -like "Azurestack-$ApplicationName*" } | Select-Object -Last 1
#endregion
#region Create new SPN if one does not exist
if ($SPNObjectCheck) {
Write-Output -InputObject "SPN details`n$($ApplicationName): $($SPNObjectCheck | Out-String)"
} else {
Write-Output -InputObject "No existing SPN found"
Write-Output -InputObject "Create new SPN '$($ApplicationName)'"
$SPNObjectJob = Invoke-Command -Session $PepSession -ScriptBlock { New-GraphApplication -Name $using:ApplicationName -ClientCertificates $using:CertificateObject } -AsJob | Wait-Job
if ($SPNObjectJob.State -ne "Completed") {
throw "$($SPNObjectJob.ChildJobs | Receive-Job)"
}
$SPNObject = $SPNObjectJob.ChildJobs.Output
Write-Output -InputObject "SPN details`n$($ApplicationName): $($SPNObject | Out-String)"
$FullApplicationName = $SPNObject.ApplicationName
#endregion
}
#region Assign SPN the 'Owner' role for the 'Default Provider Subscription'
Write-Output -InputObject "Assign SPN '$($ApplicationName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
if ($FullApplicationName) {
$SPNADFSApp = Get-AzADServicePrincipal | Where-Object { $_.DisplayName -like "$($FullApplicationName)" }
} else {
$SPNADFSApp = Get-AzADServicePrincipal | Where-Object { $_.DisplayName -like "*$($ApplicationName)*" } | Select-Object -Last 1
}
$SPNRoleAssignmentCheck = Get-AzRoleAssignment -ObjectId $SPNADFSApp.AdfsId
if (!($SPNRoleAssignmentCheck) -or ($SPNRoleAssignmentCheck.RoleDefinitionName -ne $AzureStackRole)) {
$null = New-AzRoleAssignment -RoleDefinitionName $AzureStackRole -ServicePrincipalName $SPNADFSApp.ApplicationId.Guid
#region Verify SPN has been assigned the 'Owner' role for the 'Default Provider Subscription'
$SPNRoleAssignment = Get-AzRoleAssignment -ObjectId $SPNADFSApp.AdfsId
if (!($SPNRoleAssignment) -or ($SPNRoleAssignment.RoleDefinitionName -ne $AzureStackRole)) {
throw "Failed to assign SPN '$($ApplicationName)' the '$($AzureStackRole)' role for the Default Provider Subscription"
}
#endregion
}
#endregion
#region Assign AD group 'AzureStackOwners' the 'Owner' role for the 'Default Provider Subscription'
Write-Output -InputObject "Assign AD group '$($ADGroupName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
$ADGroup = Get-AzADGroup -DisplayNameStartsWith $ADGroupName
$SubId = (Get-AzSubscription -SubscriptionName "Default Provider Subscription").Id
$OwnerRoleId = (Get-AzRoleDefinition -Name $AzureStackRole).Id
$APIPayloadHash = @{
"properties" = @{
"roleDefinitionId" = "/subscriptions/$($SubId)/providers/Microsoft.Authorization/roleDefinitions/$($OwnerRoleId)"
"principalId" = "$($ADGroup.AdfsId)"
}
} | ConvertTo-Json -Depth 50
$APIPath = "/subscriptions/$($SubId)/providers/Microsoft.Authorization/roleAssignments/$($OwnerRoleId)?api-version=2015-07-01"
$APIResponse = Invoke-AzRestMethod -Path $APIPath -Method "PUT" -Payload $APIPayloadHash
if ($APIResponse.StatusCode -ne "201") {
throw "Failed to create role assignment for ""$($ADGroup.DisplayName)"" in subscription ""$($SubId)"" with role ""$($AzureStackRole)"" and role ID ""$($OwnerRoleId)"""
}
#endregion
#region Verify AD group 'AzureStackOwners' has been assigned the 'Owner' role for the 'Default Provider Subscription'
$ADGroupRoleAssignment = Get-AzRoleAssignment -ObjectId $ADGroup.AdfsId
if (!($ADGroupRoleAssignment) -or ($ADGroupRoleAssignment.RoleDefinitionName -ne $AzureStackRole)) {
throw "Failed to assign AD group '$($ADGroupName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
}
#endregion
#region Obtain authentication information
# GUID of the directory tenant
$TenantId = (Get-AzContext).Tenant.Id
Write-Output -InputObject "TenantId: $($TenantId)"
Write-Output -InputObject ""
Write-Output -InputObject "ApplicationName: $($SPNADFSApp.DisplayName)"
Write-Output -InputObject ""
Write-Output -InputObject "ApplicationId: $($SPNADFSApp.ApplicationId.Guid)"
Write-Output -InputObject ""
Write-Output -InputObject "CertificateThumbprint: $($CertificateThumbprint)"
Write-Output -InputObject ""
Write-Output -InputObject "Admin ARM Endpoint: $($AzureStackAdminArmEndpoint)"
#endregion
#region Verify if SPN can authenticate to Azure Stack Hub Admin Management Endpoint
Write-Output -InputObject "Verify if SPN can authenticate to Azure Stack Hub Admin Management Endpoint"
$null = Clear-AzContext -Force
$null = Connect-AzAccount -Environment $EnvironmentName -ServicePrincipal -Tenant $TenantId -ApplicationId $SPNADFSApp.ApplicationId.Guid -CertificateThumbprint $CertificateThumbprint
if (((Get-AzContext).Subscription).Name -notlike "Default Provider Subscription") {
throw "Failed to obtain access to the 'Default Provider Subscription'. Please verify the SPN has been assigned the '$($AzureStackRole)' role for the 'Default Provider Subscription'."
} else {
Write-Output -InputObject "Your SPN can successfully authenticate with ARM Endpoint $($AzureStackAdminArmEndpoint) and has got access to the 'Default Provider Subscription'"
}
#endregion
#region Remove sessions
if ($PepSession) {
Write-Output -InputObject "Removing PSSSession to the Privileged Endpoint"
Remove-PSSession -Session $PepSession
}
$CheckContext = Get-AzContext | Where-Object { $_.Environment -like $EnvironmentName }
if ($CheckContext) {
Write-Output -InputObject "Disconnecting from AzS Hub Admin Management Endpoint: $($CheckContext.Environment.ResourceManagerUrl)"
$null = Disconnect-AzAccount
}
#endregion
CAUTION
Using a client secret is less secure than using an X509 certificate credential. Not only is the authentication mechanism less secure, but it also typically requires embedding the secret in the client app source code. As such, for production apps, you’re strongly encouraged to use a certificate credential.
#region Declare variables
$CloudAdminUsername = "CloudAdmin@azurestack.local"
[SecureString]$CloudAdminPassword = ConvertTo-SecureString "Password123!" -AsPlainText -Force
$ApplicationName = "ADFSAppCert"
$AzureStackRole = "Owner"
$ADGroupName = "AzureStackHubOwners"
$AzureStackAdminArmEndpoint = "https://adminmanagement.local.azurestack.external/"
$EnvironmentName = "AzureStackAdmin"
$PepCreds = New-Object -TypeName System.Management.Automation.PSCredential -ArgumentList $CloudAdminUsername, $CloudAdminPassword
$PepIPAddress = "x.x.x.224" # e.g. 10.5.30.224
#endregion
#region Register and set an Az environment that targets your Azure Stack Hub instance
Write-Output -InputObject "Connecting to Azure Stack Hub Admin Management Endpoint - $(AzureStackAdminArmEndpoint)"
$null = Add-AzEnvironment -Name $EnvironmentName -ARMEndpoint $AzureStackAdminArmEndpoint
$null = Connect-AzAccount -Environment $EnvironmentName -UseDeviceAuthentication # Interactive prompt
if (((Get-AzContext).Subscription).Name -notlike "Default Provider Subscription") {
throw "Failed to obtain access to the 'Default Provider Subscription'. Please verify the user has been assigned the '$($AzureStackRole)' role for the 'Default Provider Subscription'."
}
#endregion
#region Create a PSSession to the Privileged Endpoint VM
Write-Output -InputObject "Create a PowerShell Session to the Privileged Endpoint VM"
$PepSession = New-PSSession -ComputerName $PepIPAddress -ConfigurationName PrivilegedEndpoint -Credential $PepCreds -SessionOption (New-PSSessionOption -Culture en-US -UICulture en-US)
#endregion
#region Check for existing SPN
Write-Output -InputObject "Check for existing SPN '$($ApplicationName)'"
$SPNObjectCheckJob = Invoke-Command -Session $PepSession -ScriptBlock { Get-GraphApplication } -AsJob | Wait-Job
if ($SPNObjectCheckJob.State -ne "Completed") {
throw "$($SPNObjectCheckJob.ChildJobs | Receive-Job)"
}
$SPNObjectCheck = $SPNObjectCheckJob.ChildJobs.Output | Where-Object { $_.Name -like "Azurestack-$ApplicationName*" } | Select-Object -Last 1
#endregion
#region Create new SPN if one does not exist
if ($SPNObjectCheck) {
Write-Output -InputObject "SPN details`n$($ApplicationName): $($SPNObjectCheck | Out-String)"
} else {
Write-Output -InputObject "No existing SPN found"
Write-Output -InputObject "Create new SPN '$($ApplicationName)'"
$SPNObjectJob = Invoke-Command -Session $PepSession -ScriptBlock { New-GraphApplication -Name $using:ApplicationName -GenerateClientSecret } -AsJob | Wait-Job
if ($SPNObjectJob.State -ne "Completed") {
throw "$($SPNObjectJob.ChildJobs | Receive-Job)"
}
$SPNObject = $SPNObjectJob.ChildJobs.Output
Write-Output -InputObject "SPN details`n$($ApplicationName): $($SPNObject | Out-String)"
$FullApplicationName = $SPNObject.ApplicationName
$SPNClientId = $SPNObject.ClientId
$SPNClientSecret = $SPNObject.ClientSecret | ConvertTo-SecureString -AsPlainText -Force
$SPNCreds = New-Object -TypeName System.Management.Automation.PSCredential -ArgumentList $SPNClientId, $SPNClientSecret
#endregion
}
#region Assign SPN the 'Owner' role for the 'Default Provider Subscription'
Write-Output -InputObject "Assign SPN '$($ApplicationName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
if ($FullApplicationName) {
$SPNADFSApp = Get-AzADServicePrincipal | Where-Object { $_.DisplayName -like "$($FullApplicationName)" }
} else {
$SPNADFSApp = Get-AzADServicePrincipal | Where-Object { $_.DisplayName -like "*$($ApplicationName)*" } | Select-Object -Last 1
}
$SPNRoleAssignmentCheck = Get-AzRoleAssignment -ObjectId $SPNADFSApp.AdfsId
if (!($SPNRoleAssignmentCheck) -or ($SPNRoleAssignmentCheck.RoleDefinitionName -ne $AzureStackRole)) {
$null = New-AzRoleAssignment -RoleDefinitionName $AzureStackRole -ServicePrincipalName $SPNADFSApp.ApplicationId.Guid
#region Verify SPN has been assigned the 'Owner' role for the 'Default Provider Subscription'
$SPNRoleAssignment = Get-AzRoleAssignment -ObjectId $SPNADFSApp.AdfsId
if (!($SPNRoleAssignment) -or ($SPNRoleAssignment.RoleDefinitionName -ne $AzureStackRole)) {
throw "Failed to assign SPN '$($ApplicationName)' the '$($AzureStackRole)' role for the Default Provider Subscription"
}
#endregion
}
#endregion
#region Assign AD group 'AzureStackOwners' the 'Owner' role for the 'Default Provider Subscription'
Write-Output -InputObject "Assign AD group '$($ADGroupName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
$ADGroup = Get-AzADGroup -DisplayNameStartsWith $ADGroupName
$SubId = (Get-AzSubscription -SubscriptionName "Default Provider Subscription").Id
$OwnerRoleId = (Get-AzRoleDefinition -Name $AzureStackRole).Id
$APIPayloadHash = @{
"properties" = @{
"roleDefinitionId" = "/subscriptions/$($SubId)/providers/Microsoft.Authorization/roleDefinitions/$($OwnerRoleId)"
"principalId" = "$($ADGroup.AdfsId)"
}
} | ConvertTo-Json -Depth 50
$APIPath = "/subscriptions/$($SubId)/providers/Microsoft.Authorization/roleAssignments/$($OwnerRoleId)?api-version=2015-07-01"
$APIResponse = Invoke-AzRestMethod -Path $APIPath -Method "PUT" -Payload $APIPayloadHash
if ($APIResponse.StatusCode -ne "201") {
throw "Failed to create role assignment for ""$($ADGroup.DisplayName)"" in subscription ""$($SubId)"" with role ""$($AzureStackRole)"" and role ID ""$($OwnerRoleId)"""
}
#endregion
#region Verify AD group 'AzureStackOwners' has been assigned the 'Owner' role for the 'Default Provider Subscription'
$ADGroupRoleAssignment = Get-AzRoleAssignment -ObjectId $ADGroup.AdfsId
if (!($ADGroupRoleAssignment) -or ($ADGroupRoleAssignment.RoleDefinitionName -ne $AzureStackRole)) {
throw "Failed to assign AD group '$($ADGroupName)' the '$($AzureStackRole)' role for the 'Default Provider Subscription'"
}
#endregion
#region Obtain authentication information
# GUID of the directory tenant
$TenantId = (Get-AzContext).Tenant.Id
Write-Output -InputObject "TenantId: $($TenantId)"
Write-Output -InputObject ""
Write-Output -InputObject "ApplicationName: $($SPNADFSApp.DisplayName)"
Write-Output -InputObject ""
Write-Output -InputObject "ApplicationId: $($SPNADFSApp.ApplicationId.Guid)"
Write-Output -InputObject ""
Write-Output -InputObject "ClientSecret: $($SPNObject.ClientSecret)"
Write-Output -InputObject ""
Write-Output -InputObject "Admin ARM Endpoint: $($AzureStackAdminArmEndpoint)"
#endregion
#region Verify if SPN can authenticate to Azure Stack Hub Admin Management Endpoint
Write-Output -InputObject "Verify if SPN can authenticate to Azure Stack Hub Admin Management Endpoint"
$null = Clear-AzContext -Force
$null = Connect-AzAccount -Environment $EnvironmentName -ServicePrincipal -Tenant $TenantId -Credential $SPNCreds
if (((Get-AzContext).Subscription).Name -notlike "Default Provider Subscription") {
throw "Failed to obtain access to the 'Default Provider Subscription'. Please verify the SPN has been assigned the '$($AzureStackRole)' role for the 'Default Provider Subscription'."
} else {
Write-Output -InputObject "Your SPN can successfully authenticate with ARM Endpoint $($AzureStackAdminArmEndpoint) and has got access to the 'Default Provider Subscription'"
}
#endregion
#region Remove sessions
if ($PepSession) {
Write-Output -InputObject "Removing PSSSession to the Privileged Endpoint"
Remove-PSSession -Session $PepSession
}
$CheckContext = Get-AzContext | Where-Object { $_.Environment -like $EnvironmentName }
if ($CheckContext) {
Write-Output -InputObject "Disconnecting from AzS Hub Admin Management Endpoint: $($CheckContext.Environment.ResourceManagerUrl)"
$null = Disconnect-AzAccount
}
#endregion
2 - Azure Local
Dell AX System for Azure Local
Delivered as an Azure service, run virtualized applications on-premises with full stack lifecycle management while easily connecting resources to Azure.
Refresh and modernize aging virtualization platforms
Integrate with Azure for hybrid capabilities
Provide compute and storage at remote branch offices
Deploy and manage Azure cloud and Azure Local anywhere with Azure Arc as a single control plane
2.1 - Storage Stack
2.1.1 - Storage Stack Overview
Understanding storage stack is crucial for understanding what technologies are involved and how (where storage replica is, where is ReFS Multi-resilient Volume, …). Understanding how layers are stacked will also help when IO flow is troubleshooted - like reviewing performance counters or troubleshooting core functionality.
Traditional stack compared to storage spaces stack (note that MPIO is missing, but for Storage Spaces Direct it’s not needed as there is only one path to the physical device, so it was omitted)
You can notice 4 “new” layers, but actually it’s just Spaces layer (Spaceport) and Storage Bus Layer.
To better understand what’s in the stack, you can also explore some parts with PowerShell
Anyway, let’s explore layers a bit. Following info is based on storage description someone somewhere created and pushed to internet. The only version found was from webarchive and can be accessed here .
Layers below S2D Stack
Port & Miniport driver
storport.sys & stornvme.sys
Port drivers implement the processing of an I/O request specific to a type of I/O port, such as SATA, and are implemented as kernel-mode libraries of functions rather than actual device drivers. Port driver is written by Microsoft (storport.sys ). If third party wants to use write their own device driver (like HBA), then it will use miniport driver (except if device is NVMe, then miniport driver is Microsoft stornvme.sys )
Miniport drivers usually use storport. performance enhancements such as support for the paralell execution of IO.
storage port drivers
storage miniport drivers
Class Driver
disk.sys
A storage class driver (typically disk.sys ) uses the well-established SCSI class/port interface to control a mass storage device of its type on any bus for which the system supplies a storage port driver (currently SCSI, IDE, USB and IEEE 1394). The particular bus to which a storage device is connected is transparent to the storage class driver.
Storage class driver is responsible for claiming devices, interpreting system I/O requests and many more
In Storage Spaces stack (Virtual Disk) disk.sys is responsible for claiming Virtual Disk exposed by spaceport (storage spaces)
Partition Manager
partmgr.sys
Partitions are handled by partmgr.sys . Partition is usually GPT or MBR (preferably GPT as MBR has many limitations such as 2TB size limit)
As you can see in the stack, there are two partition managers. One partition layout is on physical disk and it is then consumed by storage spaces (spaceport).
On the picture below you can see individual physical disk from spaces exposed and it’s partitions showing metadata partition and partition containing pool data (normally not visible as it’s hidden by partmgr.sys when it detects spaces).
S2D Stack
Storage Bus Layer
clusport.sys and clusblft.sys
These two drivers (client/server) are exposing all physical disk to each cluster node, so it looks like all physical disks from every cluster node are connected to each server. For interconnect is SMB used, therefore high-speed RDMA can be used (recommended).
It also contains SBL cache.
Spaceport
spaceport.sys
Claims disks and adds them to storage spaces pool. It creates partitions where internal data structures are metadata are kept (see screenshot in partition manager).
Defines resiliency when volume (virtual disk) is created (creates/distributes extents across physical disks)
Virtual Disk
disk.sys is now used by storage spaces and exposes virtual disk that was provisioned using spaceport.sys
Layers above S2D Stack
Volume Manager
dmio.sys , volmgr.sys
Volumes are created on top of the partition and on volumes you can then create filesystems and expose it to the components higher in the stack.
Volume Snapshot
volsnap.sys
Volsnap is the component that creates system provider for the volume shadow copy service (VSS) . This service is controller by vssadmin.exe
BitLocker
fvevol.sys
BitLocker is well known disk encryption software that is on the market since Windows Vista. In PowerShell you can expose volume status with Get-BitLockerVolume command.
Filter Drivers
Interesting about filter drivers is, that all FileSystem drivers are actually filter drivers - special ones, File System Drivers - like REFS.sys , NTFS.sys , Exfat.sys .
You can learn more about filesystem using fsutil
There are also many first party and third party filter drivers. You can expose those with fltmc command
As you can see on above example, there are many filters like Cluster Shared Volume (CsvNSFlt, CsvFLT), deduplication (Dedup), shared vhd (svhdxflt), storage QoS (storqosflt) and many more. Each filter driver has defined altitude and 3rd parties can reserve theirs .
2.1.2 - Layers Below S2D Stack
2.1.2.1 - Storage Devices
Resources
Microsoft Documentation
NVMe vs SATA
Interfaces
While SATA is still well performing for most of the customers (see performance results), NVMe offers benefit of higher capacity and also more effective protocol (AHCI vs NVMe), that was developed specifically for SSDs (opposite to AHCI, that was developed for spinning media). SATA/SAS is however not scaling well with the larger disks.
There is also another aspect of performance limitation of SATA/SAS devices - the controller. All SATA/SAS devices are connected to one SAS controller (non-raid) that has limited speed (only one PCI-e connection).
Drive Connector is universal (U2, also known as SFF-8639)
NVMe drives are mapped directly to CPU
NVMe backplane connection - Example AX7525 - 16 PCIe Gen4 lanes in each connection (8 are used), 12 connections in backplane, in this case no PCIe switches.
Storage Protocol
SSDs were originally created to replace conventional rotating media. As such they were designed to connect to the same bus types as HDDs, both SATA and SAS (Serial ATA and Serial Attached SCSI).
However, this imposed speed limitations on the SSDs. Now a new type of SSD exists that attaches to PCI-e. Known as NVMe SSDs or simply NVMe.
For 1M IOPS, NVMe has more than 50% less latency with less than 50% CPU Cycles used . It is due to improved protocol (AHCI vs NVMe)
Storage Configurations
(slowest to fastest)
Hybrid (HDD+SSD)
All Flash (All SSD)
NVMe+HDD
All-NVMe
When combining multiple media types, faster media will be used as caching. While it is recommended to use 10% of the capacity for cache, it should be noted, that it is just important to not spill the cache with the production workload, as it will dramatically reduce performance. Therefore all production workload should fit into the Storage Bus Layer Cache (cache devices). The sweet spot (price vs performance) is combination of fast NVMe (mixed use or write intensive) with HDDs. For performance intensive workloads it’s recommended to use all-flash solutions as caching introduces ~20% overhead + less predicable behavior (data can be already destaged…), therefore it is recommended to use All-Flash for SQL workloads.
Performance drop when spilling cache devices:
OS Disks
In Dell Servers are BOSS (Boot Optimized Storage Solution) cards used. In essence it card wih 2x m2 2280 NVMe disks connected to PCI-e with configurable non-RAID/RAID 1
Consumer-Grade SSDs
You should avoid any consumer grade SSDs as consumer grade SSDs might contain NAND with higher latency (therefore there can be performance drop after spilling FTL buffer) or because consumer grade SSDs are not power protected (PLP). You can learn more about why consumer-grade SSDs are not good idea in a blog post . Consumer-grade SSDs do also have lower DWPD (Disk Written Per Day). You can learn about DWPD in this blogpost
Exploring Stack with PowerShell
Get-PhysicalDisk
$Server = "axnode1"
Get-PhysicalDisk -CimSession $Server | Format-Table -Property FriendlyName, Manufacturer, Model, SerialNumber, MediaType, BusType, SpindleSpeed, LogicalSectorSize, PhysicalSectorSize
From screenshot you can see, that AX640 BOSS card reports as SATA device with Unspecified Mediatype, while SAS disks are reported as SSDs, with SAS BusType. Let’s deep dive into BusType/MediaType a little bit (see table below)
Storage Spaces requires BusType SATA/SAS/NVMe or SCM. BusType RAID is unsupported.
You can also see Logical Sector Size and Physical Sector size. This refers to Drive Type (4K native vs 512E vs 512).
“LogicalSectorSize” value
“PhysicalSectorSize” value
Drive type
4096
4096
4K native
512
4096
Advanced Format (also known as 512E)
512
512
512-byte native
Reference
Storage Reliability Counter
Once disk is added to storage spaces, S.M.A.R.T. attributes can be filtered out. For reading disk status (such as wear level temperatures…) can be get-storagereliability counter used.
$Server = "axnode1"
Get-PhysicalDisk -CimSession $Server | Get-StorageReliabilityCounter -CimSession $Server | Format-Table -Property DeviceID, Wear, Temperature*, PowerOnHours, ManufactureDate, ReadLatencyMax, WriteLatencyMax, PSComputerName
From the results below you can see that SATA vs SAS vs NVMe is 590092 vs 738507 vs 1496373 4k 100% read IOPS. All measurements were done with VMFleet 2.0 https://github.com/DellGEOS/AzureStackHOLs/tree/main/lab-guides/02-TestPerformanceWithVMFleet
The difference between SAS and SATA is also 8 vs 4 disks in each node. The difference between SAS and NVMe is more than double.
2.2 - Support Matrix
NOTE
Azure Stack HCI version 22H2 reached end of support on May 31st, 2025. You will not receive monthly security and quality updates from Microsoft. Microsoft recommends that customers upgrade their operating system to 23H2 to continue receiving updates.
Dell Technologies has worked with Microsoft to validate the Azure Stack HCI 22H2 OS to Azure Stack HCI 23H2 OS upgrade on stretched clusters. Microsoft has provided the remediation in LCU 9B for the defect that caused metadata corruption on storage replica volumes when upgrading the host operating system. Instructions for implementing the operating system upgrade are now available.
For more information, see Upgrade stretched clusters from Azure Stack HCI OS, version 22H2 to 23H2
2.2.1 - Azure Local Support Matrix (Dell 2603)
2.2.1.1 - Azure Local Support Matrix for 14G-15G (Dell 2603)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-640 Windows Server 2022 Datacenter Azure Stack HCI-24H2
AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
AX-6515 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-650 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 9M80P 2.25.0 AX-640 AX-740xd NA
BIOS Firmware DUP 0D4N7 2.23.1 AX-6515 NA
BIOS Firmware DUP JR4VV 2.23.1 AX-7525 NA
BIOS Firmware DUP GWT21 1.20.2 AX-650 AX-750 NA
iDRAC9 with Lifecycle Controller Firmware DUP VP556 7.00.00.183 AX-640 AX-740xd NA
iDRAC9 with Lifecycle Controller Firmware DUP 924YT 7.30.10.50 AX-6515 AX-7525 AX-650 AX-750 NA
Non-expander Storage Backplane Firmware DUP VV85D 4.35 AX-6515 AX-640 AX-740xd NA
Non-expander Storage Backplane Firmware DUP G69W6 7.16 AX-7525 AX-750 NA
Non-expander Storage Backplane Firmware DUP 5DV1W 7.16 AX-650 NA
NVMe Switch Storage Backplane Firmware DUP 5XJWN 1.05 AX-750 NA
Expander Storage Backplane Firmware DUP H9PV3 1.2 AX-7525 AX-750 NA
Expander Storage Backplane Firmware DUP 60K1J 2.52 AX-640 AX-740xd NA
Expander Storage Backplane Firmware DUP 2F90T 2.46 AX-6515 NA
Chipset driver for 14G Intel platforms Driver DUP 4DDMJ 10.1.19913.8607 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
Chipset driver for 15G AMD platforms Driver DUP N28TF 6.11.12.245 AX-6515 AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-650 AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 238XW 6.1.0.0 AX-640 AX-740xd AX-6515 AX-7525 AX-650 AX-750 NA
CPLD Firmware DUP 9N4DH 1.0.6 AX-640 NA
CPLD Firmware DUP G65GH 1.1.4 AX-740xd NA
CPLD Firmware DUP 79XGF 1.0.7 AX-6515 NA
CPLD Firmware DUP 4NMC7 1.2.0 AX-7525 NA
CPLD Firmware DUP FCTDF 1.1.1 AX-650 AX-750 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1GbE On-Board LOM JDN4V Management NA 32W7Y 23.61.3 WYPPJ 236.1.155.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-650
CV5V6
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A 32W7Y 23.61.3 WYPPJ 236.1.155.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-6515
CV5V6
Broadcom 5720 Dual Port 1GbE On-Board LOM 6V45N Management NA 32W7Y 23.61.3 WYPPJ 236.1.155.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-750
CV5V6
Broadcom 5720 Dual Port 1GbE On-Board LOM 74H08 Management NA 32W7Y 23.61.3 WYPPJ 236.1.155.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-7525
CV5V6
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-640 AX-740xd
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP 20NJD Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC R887V Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 R640 Storage Spaces Direct RN
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH MRT0D Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-740xd
Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 YGRX3
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH 71C1T Management Compute (Premium) Storage (Premium) RoCEv2 XY16R 16.35.30.06 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP 9FTMY
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 F7V1F
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 JGWVY
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH TDNNT
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP V5DG9
NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 DN78C Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-650 AX-750 AX-7525
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC 165T0 Management N/A 9KYR0 16.20.00 VYWY1 36.20.02 Windows Server 2022 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic 57800 2x10Gb BT + 2x1Gb BT NDC G8RPD
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T and Dual Port 1GbE BASE-T, rNDC 0D1WT Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC X1TD1 Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC XVVY1
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP 415DX Management Compute (Premium) Storage (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd
QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC 4KF8J
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH 51GRM
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A10 NVIDIA NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 6KNWW 94.02.5C.00.04 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU 8F04V 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 528.89 WHQL Yes AX-650 AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU W3C1G 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 RV08M 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 528.89 WHQL Yes AX-650 AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-750 AX-7525 Windows Server 2025 Datacenter Azure Stack HCI-24H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU HCKJM 90.04.96.00.01 528.89 WHQL No AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU 7PH29 90.04.96.00.01 528.89 WHQL No AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-S1 2MFVD 3P39V 2.5.13.3024 7004G 1.2.0.1055 AX-6515 AX-7525 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
BOSS-S2 FGNRW TTR5R 2.5.13.4009 7004G 1.2.0.1055 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 Inbox 2.51.27.80 AX-640 AX-740XD AX-6515 Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 Inbox 2.51.27.80 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA M.2 NA Intel S3520 SSDSC2BB120G7R 394XT CHJGV DL43 120 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV240TCB TC2RP H6NHD E013 240 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV480TCB GPGC0 H6NHD E013 480 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV240TDU T2GFX KT63Y J008 240 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV480TDS 7RKD7 KT63Y J008 480 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville RR S4520 SSDSCKKB240GZR CM88M VJPKG DL7C 240 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville S4510 SSDSCKKB240G8R DMC15 Y1P10 DL6R 240 GB Boot
SSD SATA M.2 Read Intensive Micron 5400 MTFDDAV240TGC-1BC1ZABDA T4MJ3 RJ0WY K003 240 GB Boot
SAS 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 2.5 NA Seagate Avenger ST2000NX0463 TMVN7 GW3V7 NT32 2 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt DL2400MM0159 RWR8F DRHV4 ST5J 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ST2400MM0159 36YG1 7N5DH ST7G 2.4 TB Capacity
HDD SAS 2.5 NA Toshiba AL15SE AL15SEB24EQY F9NWJ J11N2 EF09 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ServoBP BL2400MM0159 1D0F5 00P56 SBSA 2.4TB Capacity
SATA 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 2.5 NA Seagate Avenger ST2000NX0423 VR92X GMW4P NB33 2 TB Capacity
SATA 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 3.5 NA HGST Aries K Plus HUS726020ALA610 8NP2N KH52Y KV46 2 TB Capacity
HDD SATA 3.5 NA HGST Aries K Plus HUS726040ALA610 61FFW KH52Y KV46 4 TB Capacity
HDD SATA 3.5 NA HGST Rainier MLK HUS722T2TALA600 V9H6C V3DJM MU03 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA200NY NPVM6 6D4CG FK5D 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA400NY 95M6K 6D4CG FK5D 4 TB Capacity
HDD SATA 3.5 NA Seagate Nemo ST2000NM0018-2F3130 W8FW5 CMK5N EA04 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST2000NM0145-2DC104 WG9R0 M5GJ1 DB34 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST4000NM0265-2DC107 MWHY9 M5GJ1 DB34 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-A HUS726T4TALA6L0 YH3T9 HV5HH PV09 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-AP HUS728T8TALE6L0 1WMVC T0RX4 RT09 8 TB Capacity
HDD SATA 3.5 NA HGST Libra HE10 HUH721008ALE600 KRV2W H12N2 LT21 8 TB Capacity
HDD SATA 3.5 NA Seagate Makara Plus ST8000NM0205-2FF112 92MDW MR6RH PB53 8 TB Capacity
HDD SATA 3.5 NA Toshiba MG06 MG06ACA800EY 9X09C PT7D8 GA09 8 TB Capacity
HDD SATA 3.5 NA HGST Leo-A He12 HUH721212ALE600 T2YHT JCYF6 NT11 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG07 MG07ACA12TEY 753F0 0942Y GB03 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AC MG08ACA16TEY HPGJ4 3FWPH GC05 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA400NY W2M9N F73C5 GD05 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST4000NM016A-2HZ130 XPJ47 RWK48 CAJD 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST8000NM012A-2KE131 F4JXT TF6TF CALF 8 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST12000NM002J-2TY133 KTJTY 4MPD6 PALB 12 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST16000NM002J-2TW133 JWV1P 4MPD6 PALB 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA800EY T5XR5 X5MGP GE03 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST4000NM018B-2TF130 6KR2M T04YV LC0A 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Aries K Plus HUS726020ALS210 VH6FW 8W7XP KU46 2 TB Capacity
HDD SAS 3.5 NA HGST Aries K Plus HUS726040ALS210 X4FKY 8W7XP KU46 4 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA20ENY HHX14 RG9MK EG03 2 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA40ENY 1MVTT RG9MK EG03 4 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST2000NM0155 7RCGV XKD4M DT34 2 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST4000NM0295 5JH5X XKD4M DT34 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA HGST Libra HE10 HUH721008AL5200 KRDKK MGW91 LS21 8 TB Capacity
HDD SAS 3.5 NA Seagate Makara Plus ST8000NM0185 M40TH 6421F PT55 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA Seagate Mobula BP ST12000NM0158 YMN53 VTX9C RSL5 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY DK7C9 NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY KFJ7G NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 20Y02 EM06 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 8MG73 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 4N7V0 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 24HF9 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Seagate Evans ST16000NM010G CNXPV 3YP54 ESL9 16 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 GY6MD US09 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST4000NM017A KRM6X J12RT CSJA 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST8000NM014A 0N660 0HG6Y CSLE 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG F95CX EL02 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Seagate EvansBP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA WD Paris-CP WUH722012CL5200 849H4 VK0PK AS05 12TB Capacity
HDD SAS 3.5 NA WD Paris-CP WUH722016CL5200 H8HN1 VK0PK AS05 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG11SC MG11SCA16TEY GGWNH 9GW4N ES02 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG11SC MG11SCA20TEY 2FX1T 9GW4N ES02 20 TB Capacity
SATA 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF8800CCSE VCRY6 H3XHN DACB 800 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF81D60CSE DMF5Y H3XHN DACB 1.6 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK960TDT XMWMK KT63Y J008 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK3T8TGB-1BC1ZABDA 34JK8 JTW3W K403 3.84 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM960HMJP0D3 DD4G0 97D8J GD57 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM1T9HMJP0D3 K5P0T 97D8J GD57 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH960HAJR0D3 YDHYX 3J3JR HF58 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH1T9HAJR0D3 71K37 3J3JR HF58 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG960G7R TR3MY V141M DL5C 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG019T7R MWKF2 V141M DL5C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG960G8R X31G3 4DW70 DL6B 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R F8N2K 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R 55J8H 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK960TDN HY1F8 W2X8N F005 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK1T9TDN XKF5Y W2X8N F005 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE960G XW4D1 W0YR1 DBC4 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE1T92 0DXJ7 W0YR1 DBC4 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS960G3E2X149N G162V 17C3M DG02 960GB Cache,Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS1T9G3E2X149N HCR09 17C3M DG02 1.92TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG960GZR 8MHYH VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG960GZR DYMD0 VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L3960HBLTAD3 96KT6 VRG4Y HH64 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M VRG4Y HH64 1.92 TB Cache,Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB960GZR F6H8H VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB960GZR 5M8Y4 VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5200 MTFDDAK1T9TDD VJ36D W2X8N F005 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 SED MTFDDAK3T8TGA-1BC16ABDA 2DXDK JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE1T92 919J7 W0YR1 DBC4 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE3T84 8PYG5 W0YR1 DBC4 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 3GHD6 HG61 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH1T9HMLT0D3 Y24T6 93P7P HE59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS1T9G3H2X069N 962FP HFTMG DZ04 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS1T9G32FEH-7A10A 0XMV9 3DTV4 DE08 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB019T8R 33R2T 4DW70 DL6B 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB019T7R XCN15 V141M DL5C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel P89110 SSDSC2KB038T7R 3RRN8 V141M DL5C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB038T8R 1RHK2 4DW70 DL6B 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH3T8HMLT0D3 FYP5F 93P7P HE59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 3GHD6 HG61 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS3T8G32FEH-7410A D6C0R 3DTV4 DE08 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS3T8G3H2X069N 3GDK0 HFTMG DZ04 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 T3HX9 HJ64 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W T3HX9 HJ64 3.84 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA10A 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM863a MZ7LM960HMJP0D3 T2G0Y P2YRJ GC5B 960 GB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG800G H6GCD NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG1T60 5GDXH NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G JTKH5 NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 GD3N0 NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG3T20 NKM7P NGPR2 BA48 3.2 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG6T40 6NW3J NGPR2 BA48 6.4 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB080Y CN3JH 1DJXX AS10 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB096Y 503M7 1DJXX AS10 960 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB160Y GVTYD 1DJXX AS10 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB192Y V0K7V 1DJXX AS10 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB384Y 3DDFT 1DJXX AS10 3.84 TB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG800G DHRVV CPP97 B02A 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG1T60 W9G88 CPP97 B02A 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT800HBHQ0D3 GW8T1 VJY6V DWA4 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT1T6HBJR0D3 3TCV6 VJY6V DWA4 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645 MZILT1T6HAJQ0D3 DR0HX 4PPHJ DWF8 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6480BSS200 6VJC9 8W5WF G138 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6416BSS200 6NF96 8W5WF G138 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG960G WFGTH CPP97 B02A 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG1T92 2WVYG CPP97 B02A 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG3T84 91W3V CPP97 B02A 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG960G WMWKG 6DH0W BD48 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG1T92 DHWH5 6DH0W BD48 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG3T84 81H9C 6DH0W BD48 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG800G 81G77 57MM2 C40E 800GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG1T60 G4NY4 57MM2 C40E 1.6TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T20 RGP9J 57MM2 C40E 3.2TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T84 FMP6K 57MM2 C40E 3.84TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG960G J92FY 6DH0W BD48 960 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG1T92 1081V 6DH0W BD48 1.92 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG3T84 MD4YN 6DH0W BD48 3.84 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 CHJJJ NGPR2 BA48 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Plus WUSTR6416ASS200 8W6HC 7HYHH K968 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG1T6HFJAAD3 J7MWC 42TFH DWB1 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG3T2HFLTAD3 03P3V 42TFH DWB1 3.2 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG6T4HBLCAD3 24VJM 42TFH DWB1 6.4 TB Cache, Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1519ASS200 5ND33 7HYHH K968 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1538ASS200 YW17N 7HYHH K968 3.84 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA119BSS200 02X38 8W5WF G138 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA138BSS200 FP1KF 8W5WF G138 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT1T9HAJQ0D3 F0VFY J3RRK DSF8 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT3T8HALS0D3 X8F87 J3RRK DSF8 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT7T6HMLA0D3 RVYD5 J3RRK DSF8 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT1T9HBJR0D3 TMTW9 D7RNT DSA4 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT3T8HBLS0D3 CRNPH D7RNT DSA4 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS1T9HEJH0D3 086DD XNGNT DSLA 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS3T8HMLH0D3 JR1HP XNGNT DSLA 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT960HBHQ0D3 K74WN D7RNT DSA4 960 GB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT7T6HALA0D3 84C40 D7RNT DSA4 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 4CN85 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 H9TT5 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 PD02Y NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG1T92 7F2D1 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG3T84 FH1W9 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG1T92 H1P07 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG3T84 3VHY3 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG7T68 5T78C 6DH0W BD48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 VRTN9 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 2XVX2 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 YM0T1 NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG1T92 VGMCD 57MM2 C40E 1.92TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG3T84 YTVTF 57MM2 C40E 3.84TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG7T68 HCTYM 57MM2 C40E 7.68TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG1T92 TDNP7 CPP97 B02A 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG3T84 N85XX CPP97 B02A 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M4 PX05SRB384Y XCRDV 1DJXX AS10 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS3840SE70114 KXDCD NKGWD 3D03 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS1920SE70114 D4VFW NKGWD 3D03 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG1T9HFJAAD3 8WKDX 862D9 DSB1 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG3T8HFLTAD3 MP2TJ 862D9 DSB1 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG7T6HBLCAD3 00CK9 862D9 DSB1 7.68 TB Capacity
Value SAS 2.5" SSD
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS1920SE70134 K9T53 G04C8 4S0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS3840SE70134 4KPKF G04C8 4S0C 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS7680SE70134 2THYF G04C8 4S0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Kioxia Phoenix RM5 KRM5XVUG3T84 X78JM NDG7N B710 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP ISE XS3840LE70154 NWGX3 NX13G 4D0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS960LE70095 2M1NG RRWVT CPE9 960GB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS1920LE70095 K805Y RRWVT CPE9 1.92TB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS3840LE70095 FT95M RRWVT CPE9 3.84TB Cache,Capacity
SSD VSAS 2.5 Read Intensive Kioxia Phoenix RM5 KRM5XRUG7T68 5XD2F NDG7N B710 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate Lange ISE XS7680SE70074 2PKRH H3VHX EC16 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP ISE XS7680SE70154 5KW0F NX13G 4D0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS960LE70134 2RDWT G04C8 4S0C 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS1920LE70134 N6DRV G04C8 4S0C 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS3840LE70134 YM9HP G04C8 4S0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG960G 42XXC 5WMK8 BJ07 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG1T92 N15JP 5WMK8 BJ07 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG3T84 FXYGR 5WMK8 BJ07 3.84 TB Cache, Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG1T92 1FGWG 5WMK8 BJ07 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG3T84 XNXD2 5WMK8 BJ07 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG7T68 5MHY8 5WMK8 BJ07 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG960G 05MT7 1YD58 CA0C 960 GB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG1T92 59XF2 1YD58 CA0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG3T84 M0JVN 1YD58 CA0C 3.84 TB Capacity
SSD vSAS 2.5 Read Intensive Kioxia RM7 KRM7VRUG7T68 D480G 1YD58 CA0C 7.68 TB Capacity
SSD vSAS 2.5 Read Intensive Seagate Cooper XS7680SE70145 1J46N RRWVT CPE9 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Write Intensive Intel Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF SSDPE21K375GAT 3DM57 HMRK7 E201DP38 375 GB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HEHP-000D3 JD6CH 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HMJP-000D3 JDMHM 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung
PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLS-000D3 Y3XT2 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HAJQ-000D3 4WDXY NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HAJQ-000D3 K60N7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLA-000D3 08NMX NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T7T F5P84 CR0HC QDV1DP17 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T7T MCV6J CR0HC QDV1DP17 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T8T 58V30 7VJGR VDV1DP25 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T8T 2CN1T 7VJGR VDV1DP25 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF SSDPE2KE064T8T X27HY 7VJGR VDV1DP25 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use KIOXIA DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS KCM6FVUL1T60 G7N00 WJD95 3.1.7 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 1.6TB C9X5T CGXH7 1.2.4 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 3.2TB PRKTM CGXH7 1.2.4 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 12W9R 1.5.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 12W9R 1.5.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 12W9R 1.5.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR1T6HBJRAD3 0MNMV 5V3P7 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 71KRG 1.2.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 71KRG 1.2.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 71KRG 1.2.0 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD VNYK2 1.3.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD VNYK2 1.3.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 VNYK2 1.3.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Micron 7600 MTFDLAL1T6THS DCR2M VJXKC 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Micron 7600 MTFDLAL3T2THS J9TN7 VJXKC 1.0.0 3.2 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG960G DRC9H T79D5 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG3T84 17C57 T79D5 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P4510 SSDPE2KX040T8T 5GMK0 7VJGR VDV1DP25 4 TB Capacity
NVMe PCIe 2.5 Read Intensive KIOXIA DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS KCM6FRUL1T92 TXP72 WJD95 3.1.7 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX019T9T WPP9G CGXH7 1.2.4 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX038T9T KRT3G CGXH7 1.2.4 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX076T9T RNN67 CGXH7 1.2.4 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR15THALAAD3 182NW 5V3P7 2.5.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 71KRG 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 71KRG 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 71KRG 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 71KRG 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 12W9R 1.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 12W9R 1.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 12W9R 1.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 VNYK2 1.3.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK VNYK2 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N VNYK2 1.3.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G VNYK2 1.3.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 NYPRM FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL1T9THG N6RN7 VJXKC 1.0.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL3T8THG 7X0XC VJXKC 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL7T6THG Y4GJR VJXKC 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL15T3THG 5J26R VJXKC 1.0.0 15.36 TB Capacity
NVMe Add-in Cards
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC MZPLL1T6HEHP-000D3 06V6M 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC MZPLL3T2HMLS-00003 C2KKH 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC MZPLL6T4HMLS-000D3 604N5 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC MZPLL1T6HAJQ-000D3 FTX2R NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC MZPLL3T2HAJQ-00005 73KJ7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC MZPLL6T4HMLA-000D3 FW2K0 NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ1T6HBJRAD3 Y7D7D 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ6T4HALAAD3 91FXC 5CM3G 2.5.0 6.4 TB Cache, Capacity
2.2.1.2 - Azure Local Support Matrix for 16G (Dell 2603)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-660 Windows Server 2025 Datacenter Azure Stack HCI-24H2
APEX MC-660 Azure Stack HCI-24H2
APEX MC-760 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 457WM 2.9.4 AX-660 AX-760 APEX MC-660 APEX MC-760 NA
Chipset driver for 16G Intel platforms Driver DUP R40PW 10.1.19928.8615 AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC9 with Lifecycle Controller Firmware DUP 924YT 7.30.10.50 AX-660 AX-760 APEX MC-660 APEX MC-760 NA
Expander Storage Backplane Firmware DUP J9JW2 1.61 AX-760 APEX MC-760 NA
NVMe Switch Storage Backplane Firmware DUP R39FM 3.33 AX-760 APEX MC-760 NA
Non-expander Storage Backplane Firmware DUP 58MWX 7.20 AX-760 APEX MC-760 NA
Non-expander Storage Backplane Firmware DUP 9T7YG 7.20 AX-660 APEX MC-660 NA
iDRAC Service Module Firmware DUP 238XW 6.1.0.0 AX-660 AX-760 APEX MC-660 APEX MC-760 NA
CPLD Firmware DUP XJG0V 1.2.7 AX-660 AX-760 APEX MC-660 APEX MC-760 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card 5NN70 Management N/A 32W7Y 23.61.3 WYPPJ 236.1.155.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
CV5V6
Broadcom 57416 Dual Port 10Gb, Base-T, PCIe Adapter, Full Height 3TM39 Management Compute (Premium) RoCEv2 MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, PCIe Low Profile NC5VD
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 RN1M5
Broadcom 57504 Quad Port 10/25GbE, SFP28 Adapter 3Y64D Management Compute (Premium) Storage (Premium) RoCEv2 MJ0HT 36.11.56.00 78X9T 36.11.52.00 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14
Emulex LPe36002 Dual Port Fibre Channel 64Gb Adapter, PCIe LP 39T9X N/A N/A 15J5T 03.10.12 8XGGG 12.34.10 Azure Stack HCI-24H2 AX-660 AX-760
Emulex LightPulse LPe35002-M2 2-Port 32Gb Fibre Channel Adapter LP 5KW3M
Emulex LightPulse LPe35002-M2 2-Port 32Gb Fibre Channel Adapter FH CGT2C
Emulex LPe36002 Dual Port Fibre Channel 64Gb Adapter, PCIe FH D1XM2
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 APEX MC-660 APEX MC-760
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter DN78C
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-760 APEX MC-760
Marvell QLogic 2x32Gb QLE2772 FC HBA LP JJW53 N/A N/A 3XDWV 17.10.04 RF21G 37.10.04 Azure Stack HCI-24H2 AX-660 AX-760
Marvell QLogic 2x32Gb QLE2772 FC HBA FH YM4FH
Marvell QLogic 2x64Gb QLE2872C FC HBA LP W72F2 N/A N/A XMXP3 17.10.04 RF21G 37.10.04 Azure Stack HCI-24H2 AX-660 AX-760
Marvell QLogic 2x64Gb QLE2872C FC HBA FH X29W4
Network Switches
PowerFlex
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 553.62 Yes AX-760 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 553.62 Yes AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 553.62 Yes AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 553.62 Yes AX-760 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 553.62 Yes AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 553.62 Yes AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-760 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 95.02.66.00.02 553.62 Yes AX-760 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 WW56V C6MVR 2.1.13.2037 Inbox Inbox AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-660 AX-760 APEX MC-660 APEX MC-760 Windows Server 2022 Datacenter
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBA960TDZ PRV6C N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG960TDZ 0V8F7 N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X YJG7C 1.3.1 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBAXXXTFR PH7J6 JHKXR 1.4.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6480HFLUAD3 C82V9 FTVJG 1.0.1 480 GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6960HFLBAD3 8M3JN FTVJG 1.0.1 960 GB Boot
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SDA400NY 9VN79 99TKP EP02 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 GY6MD US09 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG F95CX EL02 8 TB Capacity
HDD SAS 3.5 Read Intensive Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA Seagate CimarronBP(EWP) DL4000NM019B F7DTR M7PKX LBW4 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 20Y02 EM06 12 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST12000NM007H FN7VR 3VY0D SWS9 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA16TEY MXC46 20Y02 EM06 16 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST16000NM007H R0G8W C50CR SYS9 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SCA20TEY NT45N 0H3CX EN04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-D PR2 WUH722020BL5200 1D4CR XRFX3 VS19 20 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST20000NM007H R5KP7 C50CR SYS9 20 TB Capacity
HDD SAS 3.5 NA WD London DP WUH722420AL5200 MTTCF 444T3 YS04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-CP WUH722012CL5200 849H4 VK0PK AS05 12 TB Capacity
HDD SAS 3.5 NA WD Paris-CP WUH722016CL5200 H8HN1 VK0PK AS05 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG11SC MG11SCA16TEY GGWNH 9GW4N ES02 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG11SC MG11SCA20TEY 2FX1T 9GW4N ES02 20 TB Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 3GHD6 HG61 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 T3HX9 HJ64 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L31T9HELAAD3 PTD53 D5D3W HL58 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK1T9TGA-1BC1ZABDA KXNX5 RJ0WY K003 1.92TB Capacity
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 3GHD6 HG61 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W T3HX9 HJ64 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L33T8HELAAD3 D7V89 D5D3W HL58 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84TB Capacity
SSD SATA 2.5 Mixed Use Intel S4620 SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897a MZ7L31T9HENAAD3 GR4WN V5XNY HK58 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M VRG4Y HH64 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK1T9TGB-1BC1ZABDA XRXX2 RJ0WY K003 1.92TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG1T6HFJAAD3 J7MWC 42TFH DWB1 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG3T2HFLTAD3 03P3V 42TFH DWB1 3.2 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655a MZILG6T4HBLCAD3 24VJM 42TFH DWB1 6.4 TB Cache, Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG1T9HFJAAD3 8WKDX 862D9 DSB1 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG3T8HFLTAD3 MP2TJ 862D9 DSB1 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653a MZILG7T6HBLCAD3 00CK9 862D9 DSB1 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 71KRG 1.2.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 71KRG 1.2.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 71KRG 1.2.0 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD VNYK2 1.3.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD VNYK2 1.3.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 VNYK2 1.3.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Micron 7600 MTFDLAL1T6THS DCR2M VJXKC 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Micron 7600 MTFDLAL3T2THS J9TN7 VJXKC 1.0.0 3.2 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 71KRG 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 71KRG 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 71KRG 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 71KRG 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 VNYK2 1.3.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK VNYK2 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N VNYK2 1.3.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G VNYK2 1.3.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS960GECTX088N WR2FG T1XKD 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG960G YNGYD HV8P1 2.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC960TFR KXT48 TVCWT 1.4.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC960TGP G7NCH 5F07C 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL2960HCJRAD3 6HYWM XMFKX 1.1.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR1T9HBJRAD3 WPR17 5V3P7 2.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL21T9H TGYF5 XMFKX 1.1.1 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC1T9TFR JH61J TVCWT 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC1T9TGP M7RHM 5F07C 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS1T9GEETX099N 147DR TDGKY 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC3T8TFR NDK2D TVCWT 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG3T84 RFYP9 K6597 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS3T8GECTX088N V6WP5 T1XKD 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL23T8HCLSAD3 P7G03 XMFKX 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC3T8TGP GT3F3 5F07C 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL27T6HBLAAD3 30FX3 XMFKX 1.1.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC7T6TFR 91KYJ TVCWT 1.4.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC7T6TGP RTJFW 5F07C 1.2.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS960GEETX099N 26WJ0 TDGKY 1.1.0 960GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO1T9HCJR-00AD3 G64N5 V7V0K 1.0.0 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS3T8GEETX099N 2V97V TDGKY 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO15THBLA-00AD3 VPWMR V7V0K 1.0.0 15.36TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 9MNPJ FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL1T9THG N6RN7 VJXKC 1.0.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL3T8THG 7X0XC VJXKC 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL7T6THG Y4GJR VJXKC 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7600 MTFDLAL15T3THG 5J26R VJXKC 1.0.0 15.36 TB Capacity
2.2.1.3 - Azure Local Support Matrix for 17G (Dell 2603)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-670 Windows Server 2025 Datacenter Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 11N9M 1.7.5 AX-670 AX-770 NA
Chipset driver for 17G Intel platforms Driver DUP 7TXYY 10.1.19928.8615 AX-670 AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC10 with Lifecycle Controller Firmware DUP YP95X 1.30.10.50 AX-670 AX-770 NA
Passive Backplane (1U 8xE3 x2) Firmware DUP 0M4TD 1.92 AX-670 NA
Passive Backplane (2U 8xE3 x2) Firmware DUP 7P6P5 1.92 AX-770 NA
iDRAC Service Module Firmware DUP 238XW 6.1.0.0 AX-670 AX-770 NA
FPGA Firmware DUP RYRRC 109.126.104 AX-670 AX-770 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
NVIDIA/Mellanox ConnectX-6 Dx OCP3 769PV Management Compute (Premium) Storage (Premium) RoCEv2 0WM7T 22.48.1000 3T3MK 26.001.03 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-670 AX-770
NVIDIA/Mellanox ConnectX-6 Dx PCIe LP PXKX5
NVIDIA/Mellanox ConnectX-6 Dx PCIe FH 6PKY5 Management Compute (Premium) Storage (Premium) RoCEv2 0WM7T 22.48.1000 3T3MK 26.001.03 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-770
NVIDIA/Mellanox ConnectX-6 Lx PCIe LP 74GDV Management Compute (Premium) Storage (Premium) RoCEv2 KX0W4 26.48.1000 3T3MK 26.001.03 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-670 AX-770
NVIDIA/Mellanox ConnectX-6 Lx OCP3 7GGY4
NVIDIA/Mellanox ConnectX-6 Lx PCIe FH 17W36 Management Compute (Premium) Storage (Premium) RoCEv2 KX0W4 26.48.1000 3T3MK 26.001.03 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-770
Network Switches
PowerFlex
GPUs
GPU Model Vendor Description Part Number Firmware Version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 AX-670 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
RTX PRO 6000 NVIDIA NVIDIA RTX PRO 6000 BSE 96GB 600W PCIe GPU THH68 AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 PVDY9 2.2.13.2037 Inbox Inbox AX-670 AX-770 Windows Server 2025 Datacenter Azure Stack HCI-24H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 NA Solidigm PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Boot
NVMe PCIe M.2 NA Solidigm PE9010 HFS960GEJ8X167N 4H05X YJG7C 1.3.1 960GB Boot
NVMe PCIe M.2 NA Micron 7450 MTFDKBAXXXTFR PH7J6 JHKXR 1.4.0 960GB Boot
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe E3.s Mixed Use Kioxia CD8P KCD8XPJE1T60 R64H4 50PDK 2.0.4 1.6TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Hynix PE1030 HFS1T6GFJCX180N MXDXH 0930W 1.1.0 1.6TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Samsung PM1745 MZ3LO3T2HCLSAD3 7R3TT 694C5 1.1.0 3.2TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Kioxia CM7 KCM7XVJE3T20 6J3Y1 0822W 2.0.4 3.2TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Kioxia CD8P KCD8XPJE3T20 GP5GV 50PDK 2.0.4 3.2TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Hynix PS1030 HFS3T2GFJCX171N 734CX WHGGM 1.1.0 3.2TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Hynix PE1030 HFS3T2GFJCX180N HCDFH 0930W 1.1.0 3.2TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Hynix PS1030 HFS6T4GFJCX171N DH5XD WHGGM 1.1.0 6.4TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Samsung PM1745 MZ3LO6T4HBLAAD3 FNPJC 694C5 1.1.0 6.4TB Cache, Capacity
NVMe PCIe E3.s Mixed Use Kioxia CM7 KCM7XVJE6T40 V4DNH 0822W 2.0.4 6.4TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe E3.s Read Intensive Kioxia CD8P KCD8XPJE1T92 59Y5J 50PDK 2.0.4 1.92TB Capacity
NVMe PCIe E3.s Read Intensive Hynix PE1010 HFS1T9GFJCX180N 9CC5X 0930W 1.1.0 1.92TB Capacity
NVMe PCIe E3.s Read Intensive Samsung PM1743 MZ3LO3T8HCLSAD3 831H5 8K2NH 1.1.0 3.84TB Capacity
NVMe PCIe E3.s Read Intensive Kioxia CM7 KCM7XRJE3T84 YGK8R KCGDP 2.0.0 3.84TB Capacity
NVMe PCIe E3.s Read Intensive Hynix PS1010 HFS3T8GFJCX171N 84M8H WHGGM 1.1.0 3.84TB Capacity
NVMe PCIe E3.s Read Intensive Kioxia CD8P KCD8XPJE3T84 6RC59 50PDK 2.0.4 3.84TB Capacity
NVMe PCIe E3.s Read Intensive Hynix PE1010 HFS3T8GFJCX180N 1NFG2 0930W 1.1.0 3.84TB Capacity
NVMe PCIe E3.s Read Intensive Samsung PM1743 MZ3LO7T6HBLAAD3 NKGTX 8K2NH 1.1.0 7.68TB Capacity
NVMe PCIe E3.s Read Intensive Kioxia CM7 KCM7XRJE7T68 G27W5 KCGDP 2.0.0 7.68TB Capacity
NVMe PCIe E3.s Read Intensive Hynix PS1010 HFS7T6GFJCX171N DDKCG WHGGM 1.1.0 7.68TB Capacity
NVMe PCIe E3.s Read Intensive Samsung PM1743 MZ3LO15THBLAAD3 RRYKC 8K2NH 1.1.0 15.36TB Capacity
NVMe PCIe E3.s Read Intensive Kioxia CM7 KCM7XRJE15T3 YRN98 KCGDP 2.0.0 15.36TB Capacity
NVMe PCIe E3.s Read Intensive Hynix PS1010 HFS15T3FJCX171N HK6WK WHGGM 1.1.0 15.36TB Capacity
2.2.1.4 - Azure Local Support Matrix for 45n0c (Dell 2603)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-4510c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
APEX MC-4510c Azure Stack HCI-24H2
APEX MC-4520c Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP PW2C4 1.22.1 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c NA
iDRAC9 with Lifecycle Controller Firmware DUP 924YT 7.30.10.50 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c NA
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 238XW 6.1.0.0 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c NA
Chassis Manager Firmware DUP WC84H 5 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c NA
CPLD Firmware DUP G1YRC 1.0.5 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 MJ0HT 36.11.56.00 78X9T 236.1.155.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c APEX MC-4520c
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c APEX MC-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c APEX MC-4520c
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c APEX MC-4520c
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-4520c APEX MC-4520c Windows Server 2025 Datacenter Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-4520c APEX MC-4520c Windows Server 2025 Datacenter Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 M88HH 67GHR 2.1.13.2037 Inbox AX-4510c AX-4520c APEX MC-4510c APEX MC-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG1T9TDZ G18YX N71F4 1.6.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG3T8TDZ 2RN2N N71F4 1.6.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE8030 HFS800GDC8X088N 31XDY R2TTT 1.3.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Micron 7450 MTFDKBA800TFS F9MKX JHKXR 1.4.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE9030 HFS800GDJ8X167N FYWN9 9GH86 1.2.1 800GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X YJG7C 1.3.1 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBA960TFR PH7J6 JHKXR 1.4.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG1T9TFR J927V JHKXR 1.4.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS1T9GDE0X088N MY5M4 19H08 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG3T8TFR 5FP33 JHKXR 1.4.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS3T8GDE0X088N 5JR5H 19H08 1.1.0 3.84TB Capacity
2.2.1.5 - Azure Local Golden Images (Dell 2603)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Stack HCI OS :
OS build 26100.1742 (24H2)
Azure Local Golden Images for Solution versions 12.2510.1002.* - 12.2603.1002.* with Dell SBE 5.0.2603.*
Azure Stack HCI OS Golden Image for Azure Local
Platform
Use
Instance Expansion and Machine Repair Notes
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2603 drivers, and Dell SBE 5.0.2603.1709 for AX-770, AX-670 | ISO version A00
AX-770 AX-670
Deploy Instance Expansion (Add-Server) Machine Repair
Use with Azure Local instances running Solution version 12.*.1002.* Specify Azure Local instance Solution version when running Arc registration using:Invoke-AzStackHciArcInitialization -TargetSolutionVersion [Solution Version]
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2603 drivers, and Dell SBE 5.0.2603.1641 for AX-760, AX-660, AX-4510c, AX-4520c | ISO version A00
AX-760 AX-660 AX-4510c AX-4520c APEX MC-760 APEX MC-660 APEX MC-4510c APEX MC-4520c
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2603 drivers, and Dell SBE 5.0.2603.1522 for AX-750, AX-650 | ISO version A00
AX-750 AX-650
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2603 drivers, and Dell SBE 5.0.2603.1522 for AX-7525, AX-6515 | ISO version A00
AX-7525 AX-6515
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2603 drivers, and Dell SBE 5.0.2603.1407 for AX-740xd, AX-640 | ISO version A00
AX-640 AX-740xd
2.2.1.6 - Azure Local Dell Solution Builder Extensions Release Notes (Dell 2603)
Overview
Solution Builder Extensions (SBE) for Azure Local. Firmware, Driver, and WDAC Supplemental policy for lifecycle management for Azure Local instances running on Dell AX servers.
Important Caveats
AX 17G SBE 5.0.2603.1709 does not contain the NVIDIA ConnectX-6 NIC firmware. This is due to an iDRAC defect that prevents the SBE from updating the NVIDIA ConnectX-6 NIC firmware. The NVIDIA ConnectX-6 NIC firmware in 17G AX servers must be manually updated to version 26.48.1000 for ConnectX-6 LX and version 22.48.1000 for ConnectX-6 DX prior to Azure Local instance creation.
Secure Boot 2023 Certificates must be installed on each instance machine in order for the BIOS version to be upgraded to the versions that are included in this SBE release. The Secure Boot 2023 Certificates are installed as part of installing Solution version 12.2603.1002.*, which is a prerequisite for installing these new SBE versions.
NVIDIA ConnectX NIC resets have been observed by customers under certain workloads. Affected driver version ‘25.1.26647.0’ and corresponding firmware was introduced in the SBE ‘4.2.2506.n’. SBE ‘4.2.2509.n’ and ‘4.2.2512.n’ will downgrade the NVIDIA ConnectX driver to version ‘24.4.26429.0’ and firmware versions ‘26.41.10.00’, ‘22.41.10.00’, and ‘14.32.20.04’ when installing SBE ‘5.0.2603.1641’, ‘5.0.2603.1522’, or ‘5.0.2603.1407’. Manually downgrading the firmware is no longer required. For reference, see KB000376360 .
Dell Micron 7450 and 7500 NVMe SSDs occasionally enter a panic state. For details and instructions, see KB000368482 . From the SBE table above, find the version relevant to your product and install the SBE with updated firmware that resolves the defect for the Micron 7450 and 7500 drives.
New for This Release
SBE 5.2603.1709
New for AX-670 and AX-770 Platforms
Driver and Firmware 2603 Update
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.*.1002.*
SBE 5.2603.1641
Driver and Firmware 2603 Update
Added Secure Boot 2023 certificate prerequisite check prior to BIOS update
Added automated capability for downgrading NVIDIA ConnectX-6 NIC firmware if necessary
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.2603.1002.*
SBE 5.2603.1522
Driver and Firmware 2603 Update
Added Secure Boot 2023 certificate prerequisite check prior to BIOS update
Added automated capability for downgrading NVIDIA ConnectX-6 NIC firmware if necessary
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.2603.1002.*
SBE 5.2603.1407
Driver and Firmware 2603 Update
Added Secure Boot 2023 certificate prerequisite check prior to BIOS update
Added automated capability for downgrading NVIDIA ConnectX-6 NIC firmware if necessary
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.2603.1002.*
Prerequisites
Update Firmware and Drivers Prior to Azure Local Instance Deployment
Drivers and firmware need to be installed on the servers that will be the instance members prior to deployment from the Azure Portal or using an ARM Template. This requirement is independent of the installation of the SBE. Machines imaged with Dell provided golden images will include the required Dell provided Out-of-Box drivers, but the firmware versions must still be validated and possibly updated prior to the instance deployment. The most current driver and firmware versions listed in the support matrix are recommended.
The Azure Local support matrix for Dell AX servers can be found here, Support Matrix | Solutions for Microsoft Azure .
iDRAC Access from Host OS
The iDRAC pass-through NIC must be enabled and have an IP address assigned to it. iDRAC pass-through NIC is enabled by default and has an APIPA (Automatic Private IP Addressing) IP address assigned. This IP address must be accessible by the iDRAC NIC Remote NDIS Compatible Device in the host operating system. This is a dedicated link to the host OS and cannot be accessed outside the host OS.
iDRAC access health checks are introduced starting with the December 2024 SBE releases. These health checks verify that the required iDRAC access has been implemented on each server that will be an instance member. The iDRAC access health checks run automatically as part of the standard built-in SBE health checks. These health checks must complete successfully for the SBE installation to proceed. Failure remediation instructions are provided in case the health check fails.
Manual iDRAC Access Verification
The following procedures provide a manual method for verifying the required iDRAC access. The iDRAC access health checks provide automated and more comprehensive verification method.
Example iDRAC Pass-through settings
The iDRAC NIC Remote NDIS Compatible Device in the host operating system is used by the SBE CAU plug-in to update firmware. This NIC must be enabled and have an IP address assigned to it. By default, this NIC is enabled and has an APIPA IP address assigned to it that can access the iDRAC pass-through IP address. DHCP client should not be disabled on this NIC.
This is a dedicated link to iDRAC from the host OS and cannot be accessed outside the host OS.
The IP address can be obtained using the following PowerShell command:
Get-NetAdapter -InterfaceDescription "Remote NDIS Compatible Device" | Get-NetIPAddress -AddressFamily IPv4 | Select-Object -Property IPAddress
Example:
IPAddress
---------
169.254.0.2
Azure Local instances using Non-Transparent, Unauthenticated Network Proxy
Azure Local instances using non-transparent, unauthenticated network proxy must have the iDRAC pass-through IP address in the network proxy exclusion list. For information on how to configure the non-transparent, unauthenticated network proxy see, Configure proxy settings for Azure Local .
The following example shows how to configure the APIPA IP address range 169.254.0.0/16 to be in the network proxy exclusion list.
$NoProxy = "localhost,127.0.0.1,.svc,10.0.0.0/8,172.16.0.0/12,192.168.0.0/16,.contoso.com,node1,node2,ClusterName,169.254.0.0/16"
[Environment]::SetEnvironmentVariable("NO_PROXY", $NoProxy, "Machine")
Download Connector – Automated download of future SBE release
Overview
Download Connector is a component in the SBE (Solutions Builder Extensions) that automates the downloading of new SBE bundles as they become available for your cluster. Once an SBE that includes the Download Connector is installed on your cluster, manually downloading and importing follow-on SBE version is no longer required. The update service will automate the downloading of the next available SBE for your Azure Local instance in a similar manner to how the download of the solution upgrade is automated. The Download Connector is part of the SBE version 4.1.2505.1501 and newer.
SBE versions that include the Download Connector also include system and update health checks that proactively verify the ability of the Download Connector to access the required remote resource when it comes time to download the next SBE for your cluster. System health checks are run once per day and update health checks are run at the initial phase of the update process.
Firewall Requirements
The SBE Download Connector running in the Azure Local instance needs to periodically connect to the internet resources to download SBE bundles for your cluster. The following outbound connectivity is required.
Endpoint Description
Endpoint URL
Port
SBE bundle download
dl.dell.com/*
443
SBE download catalog
downloads.dell.com/filestore/Prod/SbeDownloadCatalog/AX_SBE_Download_Catalog.xml
443
SBE download catalog redirection
aka.ms/DellAzureLocalSBEDownloadCatalog
443
Digicert Certificate Revocation Status
http://crl3.digicert.com/*
80
Digicert Certificate Revocation Status
http://crl4.digicert.com/*
80
Installation
Automated Download and Extraction
SBE releases starting with 4.1.2505.1501 and newer include the Download Connector that automates downloading and extracting the SBE.
Note
Manual download and SBE bundle extraction are unnecessary when an SBE with this capability is already installed or partially installed on the Azure Local instance.
Manual Download and Extract
CAUTION
Steps 3 and 4 must be completed to ensure that the latest SBE Discovery manifest is used.
This step is required only when an SBE is not installed in the Azure Local instance (SBE version ‘2.1.0.0’) or the installed SBE is older than version ‘4.1.2505.1501’
SBE bundle zip file has the naming convention Bundle_SBE_Dell_AS-HCI-AX-GenerationNumber_VersionNumber.zip.
Download the SBE bundle zip file for your Dell AX server generation using the download link above. The SBE bundles are specific to the AX 14G platforms, AX 15G platforms, and AX 16G platforms
Extract the three SBE files from the SBE bundle zip file. There are two xml files and one zip file. Example:
SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.xml
SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.zip
SBE_Discovery_Dell.xml
Navigate to https://aka.ms/AzureStackSBEUpdate/DellEMC and press Ctrl + S to download the SBE_Discovery_Dell.xml file
Replace the SBE_Discovery_Dell.xml file that was in the SBE bundle zip with the file downloaded in step 3
There are two options for installing the SBE package. The SBE package can be installed as part of instance creation or imported after instance creation is successfully completed. The importing method is also used to update the SBE to a newer version when the currently running SBE does not include Download Connector capability.
Installing SBE as Part of Instance Creation
Starting with June 2025 Dell golden image release, the SBE files are included in the golden image and already placed in the C:\SBE directory. The following 3 steps do not need to be performed.
On each server that will be an instance member, create the following directory: C:\SBE
Copy the three SBE files to the directory C:\SBE on each server that will be an instance member
Proceed to deploying the instance from the Azure Portal or an ARM template
Importing the SBE After Successful Azure Local Instance Creation
Create a directory on a cluster shared volume (CSV) for sideloading the SBE, e.g., C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600
Copy the three extracted SBE files to this directory
Load the SBE files by running the following command with the path to the directory that holds the three extracted SBE files
Add-SolutionUpdate -SourceFolder "C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600"
Check the state of the SBE that was just added. The state needs to be Ready.
Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE"
Verify that the Azure Local instance is in a healthy state and is ready for the SBE installation by running the following commands on one of the Azure Local instance machines:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate -PrepareOnly
Wait for the health check to complete. The solution update state will report HealthChecking while the health check is in progress.
After the health check completes, run the following command if the solution update state reports HealthCheckFailed:
$Result = (Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"}).HealthCheckResult
$Result | Where-Object { ($_.Status -ne "SUCCESS" -and $_.Severity -eq "CRITICAL" ) } | Format-List -Property Title, Status, Severity, Description, Remediation, TargetResourceName, TargetResourceType
All tests with Critical severity must have the Success status before continuing to the next step.
Start the SBE installation by running the following command:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate
The SBE installation progress can be checked by running the following command:
Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE" | Format-List -Property ResourceID, Description, State, SBEVersion, UpdateStateProperties, HealthState
For more information see, Update Azure Local via PowerShell .
Known Issues
SBE Installation May Fail with Firmware CAU Plug-in CAU Scan Error
Description
The SBE installation may fail when the Dell firmware CAU plug-in is running the CAU scan operation to identify server components that require firmware updates. The SBE installation workflow terminates and reports the following error when this condition occurs.
Microsoft.HardwareUpdatePlugin (2) plug-in reported a failure while attempting to scan for applicable updates on node <NodeName>
Additional information reported by the plug-in: (ClusterUpdateException) Encountered Exception while running ScanAsync
Note
HardwareUpdatePlugin (2) refers to the firmware CAU plug-in in the Dell SBE.
Workaround
Identify the failing node name from the error message.
Reboot iDRAC on that node via WebUI by logging in to iDRAC, selecting the menu Maintenance > Diagnostics > Reboot iDRAC .
Note
iDRAC takes a few minutes to reboot. The session to the iDRAC WebUI will drop and automatically re-establish when iDRAC completes the reboot process.
Wait for iDRAC to complete its reboot and verify you can log in.
Restart the SBE installation from Azure Update Manager or from PowerShell by running the following command on one of the Azure Local instance nodes:
Get-SolutionUpdate | Where-Object { $_.State -eq "InstallationFailed" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate
Background
The Dell firmware CAU plug-in implements the CAU scan operation to identify components that require firmware updates prior to running the CAU run operation. Azure Local machine components that do not require firmware updates are excluded from the CAU run operation. The firmware CAU plug-in obtains a list of machine components and their firmware versions from iDRAC. This error occurs when iDRAC does not respond correctly to the component inventory request issued by the firmware CAU plug-in.
Partially Installed SBE Version 4.0.0.0 When SBE Is Installed as Part of Cluster Deployment
Description
Get-SolutionUpdateEnvironment reports partially installed SBE when installing the SBE as part of Azure Local instance deployment. SBE version 4.0.0.0 indicates a partially installed Solution Builder Extension (SBE).
Get-SolutionUpdateEnvironment
ResourceId : redmond
SbeFamily : AX-16G-45n0c
HardwareModel : AX-760
LastChecked : 08/01/2026 14:09:31
PackageVersions : {Solution: 12.2512.1002.16, Services: 10.2512.0.9, Platform: 12.2512.0.3021, SBE: 4.0.0.0}
CurrentVersion : 12.2512.1002.16
CurrentSbeVersion : 4.0.0.0
LastUpdated :
State : UpdateAvailable
HealthState : Success
HealthCheckResult : {Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary...}
HealthCheckDate : 07/01/2026 17:50:07
AdditionalData : {[SBEAdditionalData, Solution Builder extension is partially installed. Please install the latest Solution Builder Extension provided by your hardware vendor. For more information, see https://aka.ms/SBE.]}
Workaround
Reinstall the same SBE version using the SBE import method or automated download method after Azure Local instance deployment successfully completes.
Background
The SBE driver CAU plug-in expects all drivers and firmware in the SBE payload to be installed on the server during or prior to deployment. However, some of the drivers in the SBE payload may not apply to the server model or components in the server model. Microsoft is aware of this limitation and is working to resolve this issue in a future release.
The partially installed SBE issue can also occur if a component firmware version installed on the server is different than what is in the SBE payload. The SBE cannot update firmware or drivers during Azure Local instance deployment.
SBE installation will not downgrade drivers that have a newer version than the same driver in the SBE payload
Dell supports the driver and firmware versions listed here, Support Matrix | Solutions for Microsoft Azure .
Description
The SBE driver CAU plug-in will not attempt to downgrade installed drivers that are higher version than the ones in its payload unless otherwise specified by Dell.
Description
SBE installation fails because the driver CAU plug-in in the SBE is unable to update the AMD DRTM driver to a newer version that is in the SBE payload. The AMD DRTM driver is one of the AMD Chipset drivers in the SBE package. The AMD DRTM driver update fails because the AMD DRTM setting was originally enabled but later disabled.
Workaround
Verify that the AMD DRTM BIOS setting is on. Re-enable the AMD DRTM setting if it is off.
The DRTM option is in the BIOS configuration: System Security -> TPM Advanced Settings -> AMD DRTM
Make sure to suspend and drain the Azure Local cluster node prior to rebooting the node. Make sure that BitLocker protection is disabled for the boot volume on the cluster node before making BIOS configuration changes. Disable BitLocker if it is enabled for the boot volume C:\ prior to rebooting the server for the BIOS changes to take effect. Reenable BitLocker for the boot drive after the server successfully reboots.
Background
AMD DRTM is an advanced security feature that is available on modern AMD CPUs and is used to protect the secure boot enclaves. The AMD DRTM setting is enabled by default on AX servers with AMD CPUs that support the DRTM feature. AMD DRTM should not be disabled.
Previous Releases
2.2.2 - Azure Local Support Matrix (Dell 2512)
2.2.2.1 - Azure Local Support Matrix for 14G-15G (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-640 Windows Server 2022 Datacenter Azure Stack HCI-24H2
AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
AX-6515 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-650 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 9M80P 2.25.0 AX-640 AX-740xd NA
T4VCN 2.24.0
BIOS Firmware DUP 74JWM 2.22.0 AX-6515 NA
BIOS Firmware DUP 2KY3W 2.22.0 AX-7525 NA
BIOS Firmware DUP 8388K 1.19.2 AX-650 AX-750 NA
12YN5 1.18.1
iDRAC9 with Lifecycle Controller Firmware DUP VP556 7.00.00.183 AX-640 AX-740xd NA
iDRAC9 with Lifecycle Controller Firmware DUP KYWDC 7.20.80.50 AX-6515 AX-7525 AX-650 AX-750 NA
Non-expander Storage Backplane Firmware DUP VV85D 4.35 AX-6515 AX-640 AX-740xd NA
Non-expander Storage Backplane Firmware DUP G69W6 7.16 AX-7525 AX-750 NA
Non-expander Storage Backplane Firmware DUP 5DV1W 7.16 AX-650 NA
NVMe Switch Storage Backplane Firmware DUP 5XJWN 1.05 AX-750 NA
Expander Storage Backplane Firmware DUP H9PV3 1.2 AX-7525 AX-750 NA
Expander Storage Backplane Firmware DUP 60K1J 2.52 AX-640 AX-740xd NA
Expander Storage Backplane Firmware DUP 2F90T 2.46 AX-6515 NA
Chipset driver for 14G Intel platforms Driver DUP 4DDMJ 10.1.19913.8607 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
Chipset driver for 15G AMD platforms Driver DUP N28TF 6.11.12.245 AX-6515 AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-650 AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-640 AX-740xd AX-6515 AX-7525 AX-650 AX-750 NA
CPLD Firmware DUP 9N4DH 1.0.6 AX-640 NA
CPLD Firmware DUP G65GH 1.1.4 AX-740xd NA
CPLD Firmware DUP 79XGF 1.0.7 AX-6515 NA
CPLD Firmware DUP 4NMC7 1.2.0 AX-7525 NA
CPLD Firmware DUP FCTDF 1.1.1 AX-650 AX-750 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1GbE On-Board LOM JDN4V Management NA 5V215 23.31.1 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-650
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A 5V215 23.31.1 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-6515
Broadcom 5720 Dual Port 1GbE On-Board LOM 6V45N Management NA 5V215 23.31.1 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-750
Broadcom 5720 Dual Port 1GbE On-Board LOM 74H08 Management NA 5V215 23.31.1 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 AX-7525
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-640 AX-740xd
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP 20NJD Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC R887V Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 R640 Storage Spaces Direct RN
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH MRT0D Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-740xd
Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 YGRX3
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH 71C1T Management Compute (Premium) Storage (Premium) RoCEv2 XY16R 16.35.30.06 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP 9FTMY
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 F7V1F
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 JGWVY
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH TDNNT
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP V5DG9
NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 DN78C Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-650 AX-750 AX-7525
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC 165T0 Management N/A 9KYR0 16.20.00 VYWY1 36.20.02 Windows Server 2022 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic 57800 2x10Gb BT + 2x1Gb BT NDC G8RPD
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T and Dual Port 1GbE BASE-T, rNDC 0D1WT Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC X1TD1 Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC XVVY1
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP 415DX Management Compute (Premium) Storage (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd
QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC 4KF8J
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH 51GRM
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A10 NVIDIA NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 6KNWW 94.02.5C.00.04 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU 8F04V 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU W3C1G 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-24H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 RV08M 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-24H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-750 AX-7525 Azure Stack HCI-24H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU HCKJM 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-24H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU 7PH29 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-S1 2MFVD 3P39V 2.5.13.3024 7004G 1.2.0.1055 AX-6515 AX-7525 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
BOSS-S2 FGNRW TTR5R 2.5.13.4009 7004G 1.2.0.1055 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 Inbox 2.51.27.80 AX-640 AX-740XD AX-6515 Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 Inbox 2.51.27.80 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-23H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA M.2 NA Intel S3520 SSDSC2BB120G7R 394XT CHJGV DL43 120 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV240TCB TC2RP H6NHD E013 240 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV480TCB GPGC0 H6NHD E013 480 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV240TDU T2GFX KT63Y J008 240 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV480TDS 7RKD7 KT63Y J008 480 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville RR S4520 SSDSCKKB240GZR CM88M VJPKG DL7C 240 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville S4510 SSDSCKKB240G8R DMC15 Y1P10 DL6R 240 GB Boot
SSD SATA M.2 Read Intensive Micron 5400 MTFDDAV240TGC-1BC1ZABDA T4MJ3 RJ0WY K003 240 GB Boot
SAS 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 2.5 NA Seagate Avenger ST2000NX0463 TMVN7 GW3V7 NT32 2 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt DL2400MM0159 RWR8F DRHV4 ST5J 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ST2400MM0159 36YG1 7N5DH ST7G 2.4 TB Capacity
HDD SAS 2.5 NA Toshiba AL15SE AL15SEB24EQY F9NWJ J11N2 EF09 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ServoBP BL2400MM0159 1D0F5 00P56 SBSA 2.4TB Capacity
SATA 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 2.5 NA Seagate Avenger ST2000NX0423 VR92X GMW4P NB33 2 TB Capacity
SATA 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 3.5 NA HGST Aries K Plus HUS726020ALA610 8NP2N KH52Y KV46 2 TB Capacity
HDD SATA 3.5 NA HGST Aries K Plus HUS726040ALA610 61FFW KH52Y KV46 4 TB Capacity
HDD SATA 3.5 NA HGST Rainier MLK HUS722T2TALA600 V9H6C V3DJM MU03 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA200NY NPVM6 6D4CG FK5D 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA400NY 95M6K 6D4CG FK5D 4 TB Capacity
HDD SATA 3.5 NA Seagate Nemo ST2000NM0018-2F3130 W8FW5 CMK5N EA04 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST2000NM0145-2DC104 WG9R0 M5GJ1 DB34 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST4000NM0265-2DC107 MWHY9 M5GJ1 DB34 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-A HUS726T4TALA6L0 YH3T9 HV5HH PV09 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-AP HUS728T8TALE6L0 1WMVC T0RX4 RT09 8 TB Capacity
HDD SATA 3.5 NA HGST Libra HE10 HUH721008ALE600 KRV2W H12N2 LT21 8 TB Capacity
HDD SATA 3.5 NA Seagate Makara Plus ST8000NM0205-2FF112 92MDW MR6RH PB53 8 TB Capacity
HDD SATA 3.5 NA Toshiba MG06 MG06ACA800EY 9X09C PT7D8 GA09 8 TB Capacity
HDD SATA 3.5 NA HGST Leo-A He12 HUH721212ALE600 T2YHT JCYF6 NT11 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG07 MG07ACA12TEY 753F0 0942Y GB03 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AC MG08ACA16TEY HPGJ4 WTNDC GC04 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA400NY W2M9N F73C5 GD05 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST4000NM016A-2HZ130 XPJ47 RWK48 CAJD 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST8000NM012A-2KE131 F4JXT TF6TF CALF 8 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST12000NM002J-2TY133 KTJTY 4MPD6 PALB 12 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST16000NM002J-2TW133 JWV1P 4MPD6 PALB 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA800EY T5XR5 65CDF GE02 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST4000NM018B-2TF130 6KR2M T04YV LC0A 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Aries K Plus HUS726020ALS210 VH6FW 8W7XP KU46 2 TB Capacity
HDD SAS 3.5 NA HGST Aries K Plus HUS726040ALS210 X4FKY 8W7XP KU46 4 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA20ENY HHX14 RG9MK EG03 2 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA40ENY 1MVTT RG9MK EG03 4 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST2000NM0155 7RCGV XKD4M DT34 2 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST4000NM0295 5JH5X XKD4M DT34 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA HGST Libra HE10 HUH721008AL5200 KRDKK MGW91 LS21 8 TB Capacity
HDD SAS 3.5 NA Seagate Makara Plus ST8000NM0185 M40TH 6421F PT55 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA Seagate Mobula BP ST12000NM0158 YMN53 VTX9C RSL5 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY DK7C9 NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY KFJ7G NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 20Y02 EM06 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 8MG73 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 4N7V0 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 24HF9 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Seagate Evans ST16000NM010G CNXPV 3YP54 ESL9 16 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 GY6MD US09 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST4000NM017A KRM6X J12RT CSJA 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST8000NM014A 0N660 0HG6Y CSLE 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG F95CX EL02 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Seagate EvansBP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
SATA 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF8800CCSE VCRY6 H3XHN DACB 800 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF81D60CSE DMF5Y H3XHN DACB 1.6 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK960TDT XMWMK KT63Y J008 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK3T8TGB-1BC1ZABDA 34JK8 JTW3W K403 3.84 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM960HMJP0D3 DD4G0 97D8J GD57 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM1T9HMJP0D3 K5P0T 97D8J GD57 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH960HAJR0D3 YDHYX 3J3JR HF58 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH1T9HAJR0D3 71K37 3J3JR HF58 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG960G7R TR3MY V141M DL5C 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG019T7R MWKF2 V141M DL5C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG960G8R X31G3 4DW70 DL6B 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R F8N2K 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R 55J8H 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK960TDN HY1F8 W2X8N F005 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK1T9TDN XKF5Y W2X8N F005 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE960G XW4D1 W0YR1 DBC4 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE1T92 0DXJ7 W0YR1 DBC4 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS960G3E2X149N G162V 4T2FN DG00 960GB Cache,Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG960GZR 8MHYH VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG960GZR DYMD0 VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L3960HBLTAD3 96KT6 VRG4Y HH64 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M VRG4Y HH64 1.92 TB Cache,Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB960GZR F6H8H VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB960GZR 5M8Y4 VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5200 MTFDDAK1T9TDD VJ36D W2X8N F005 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 SED MTFDDAK3T8TGA-1BC16ABDA 2DXDK JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE1T92 919J7 W0YR1 DBC4 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE3T84 8PYG5 W0YR1 DBC4 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 3GHD6 HG61 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH1T9HMLT0D3 Y24T6 93P7P HE59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS1T9G32FEH-7A10A 0XMV9 3DTV4 DE08 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB019T8R 33R2T 4DW70 DL6B 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB019T7R XCN15 V141M DL5C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB038T7R 3RRN8 V141M DL5C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB038T8R 1RHK2 4DW70 DL6B 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH3T8HMLT0D3 FYP5F 93P7P HE59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 3GHD6 HG61 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS3T8G32FEH-7410A D6C0R 3DTV4 DE08 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 T3HX9 HJ64 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W T3HX9 HJ64 3.84 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA10A 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92 TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG800G H6GCD NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG1T60 5GDXH NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G JTKH5 NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 GD3N0 NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG3T20 NKM7P NGPR2 BA48 3.2 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG6T40 6NW3J NGPR2 BA48 6.4 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB080Y CN3JH 1DJXX AS10 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB096Y 503M7 1DJXX AS10 960 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB160Y GVTYD 1DJXX AS10 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB192Y V0K7V 1DJXX AS10 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB384Y 3DDFT 1DJXX AS10 3.84 TB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG800G DHRVV CPP97 B02A 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG1T60 W9G88 CPP97 B02A 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT800HBHQ0D3 GW8T1 VJY6V DWA4 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT1T6HBJR0D3 3TCV6 VJY6V DWA4 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645 MZILT1T6HAJQ0D3 DR0HX 4PPHJ DWF8 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6480BSS200 6VJC9 8W5WF G138 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6416BSS200 6NF96 8W5WF G138 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG960G WFGTH CPP97 B02A 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG1T92 2WVYG CPP97 B02A 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG3T84 91W3V CPP97 B02A 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG960G WMWKG 6DH0W BD48 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG1T92 DHWH5 6DH0W BD48 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG3T84 81H9C 6DH0W BD48 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG800G 81G77 57MM2 C40E 800GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG1T60 G4NY4 57MM2 C40E 1.6TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T20 RGP9J 57MM2 C40E 3.2TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T84 FMP6K 57MM2 C40E 3.84TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG960G J92FY 6DH0W BD48 960 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG1T92 1081V 6DH0W BD48 1.92 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG3T84 MD4YN 6DH0W BD48 3.84 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 CHJJJ NGPR2 BA48 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Plus WUSTR6416ASS200 8W6HC 7HYHH K968 1.6 TB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1519ASS200 5ND33 7HYHH K968 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1538ASS200 YW17N 7HYHH K968 3.84 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA119BSS200 02X38 8W5WF G138 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA138BSS200 FP1KF 8W5WF G138 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT1T9HAJQ0D3 F0VFY J3RRK DSF8 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT3T8HALS0D3 X8F87 J3RRK DSF8 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT7T6HMLA0D3 RVYD5 J3RRK DSF8 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT1T9HBJR0D3 TMTW9 D7RNT DSA4 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT3T8HBLS0D3 CRNPH D7RNT DSA4 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS1T9HEJH0D3 086DD XNGNT DSLA 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS3T8HMLH0D3 JR1HP XNGNT DSLA 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT960HBHQ0D3 K74WN D7RNT DSA4 960 GB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT7T6HALA0D3 84C40 D7RNT DSA4 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 4CN85 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 H9TT5 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 PD02Y NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG1T92 7F2D1 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG3T84 FH1W9 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG1T92 H1P07 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG3T84 3VHY3 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG7T68 5T78C 6DH0W BD48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 VRTN9 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 2XVX2 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 YM0T1 NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG1T92 VGMCD 57MM2 C40E 1.92TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG3T84 YTVTF 57MM2 C40E 3.84TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG7T68 HCTYM 57MM2 C40E 7.68TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG1T92 TDNP7 CPP97 B02A 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG3T84 N85XX CPP97 B02A 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M4 PX05SRB384Y XCRDV 1DJXX AS10 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS3840SE70114 KXDCD NKGWD 3D03 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS1920SE70114 D4VFW NKGWD 3D03 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
Value SAS 2.5" SSD
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS1920SE70134 K9T53 G04C8 4S0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS3840SE70134 4KPKF G04C8 4S0C 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS7680SE70134 2THYF G04C8 4S0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Kioxia Phoenix RM5 KRM5XVUG3T84 X78JM NDG7N B710 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP ISE XS3840LE70154 NWGX3 NX13G 4D0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS960LE70095 2M1NG RRWVT CPE9 960GB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS1920LE70095 K805Y RRWVT CPE9 1.92TB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS3840LE70095 FT95M RRWVT CPE9 3.84TB Cache,Capacity
SSD VSAS 2.5 Read Intensive Kioxia Phoenix RM5 KRM5XRUG7T68 5XD2F NDG7N B710 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate Lange ISE XS7680SE70074 2PKRH H3VHX EC16 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP ISE XS7680SE70154 5KW0F NX13G 4D0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS960LE70134 2RDWT G04C8 4S0C 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS1920LE70134 N6DRV G04C8 4S0C 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS3840LE70134 YM9HP G04C8 4S0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG960G 42XXC 5WMK8 BJ07 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG1T92 N15JP 5WMK8 BJ07 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG3T84 FXYGR 5WMK8 BJ07 3.84 TB Cache, Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG1T92 1FGWG 5WMK8 BJ07 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG3T84 XNXD2 5WMK8 BJ07 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG7T68 5MHY8 5WMK8 BJ07 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG960G 05MT7 1YD58 CA0C 960 GB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG1T92 59XF2 1YD58 CA0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG3T84 M0JVN 1YD58 CA0C 3.84 TB Capacity
SSD vSAS 2.5 Read Intensive Kioxia RM7 KRM7VRUG7T68 D480G 1YD58 CA0C 7.68 TB Capacity
SSD vSAS 2.5 Read Intensive Seagate Cooper XS7680SE70145 1J46N RRWVT CPE9 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Write Intensive Intel Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF SSDPE21K375GAT 3DM57 HMRK7 E201DP38 375 GB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HEHP-000D3 JD6CH 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HMJP-000D3 JDMHM 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung
PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLS-000D3 Y3XT2 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HAJQ-000D3 4WDXY NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HAJQ-000D3 K60N7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLA-000D3 08NMX NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T7T F5P84 CR0HC QDV1DP17 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T7T MCV6J CR0HC QDV1DP17 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T8T 58V30 GD4X4 VDV1DP25 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T8T 2CN1T GD4X4 VDV1DP25 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF SSDPE2KE064T8T X27HY GD4X4 VDV1DP25 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use KIOXIA DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS KCM6FVUL1T60 G7N00 WJD95 3.1.7 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 1.6TB C9X5T CGXH7 1.2.4 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 3.2TB PRKTM CGXH7 1.2.4 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 12W9R 1.5.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 12W9R 1.5.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 12W9R 1.5.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR1T6HBJRAD3 0MNMV 5V3P7 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 71KRG 1.2.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 71KRG 1.2.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 71KRG 1.2.0 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG960G DRC9H T79D5 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG3T84 17C57 T79D5 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P4510 SSDPE2KX040T8T 5GMK0 GD4X4 VDV1DP25 4 TB Capacity
NVMe PCIe 2.5 Read Intensive KIOXIA DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS KCM6FRUL1T92 TXP72 WJD95 3.1.7 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX019T9T WPP9G CGXH7 1.2.4 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX038T9T KRT3G CGXH7 1.2.4 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX076T9T RNN67 CGXH7 1.2.4 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR15THALAAD3 182NW 5V3P7 2.5.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 71KRG 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 71KRG 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 71KRG 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 71KRG 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 12W9R 1.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 12W9R 1.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 12W9R 1.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 NYPRM FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
NVMe Add-in Cards
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC MZPLL1T6HEHP-000D3 06V6M 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC MZPLL3T2HMLS-00003 C2KKH 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC MZPLL6T4HMLS-000D3 604N5 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC MZPLL1T6HAJQ-000D3 FTX2R NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC MZPLL3T2HAJQ-00005 73KJ7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC MZPLL6T4HMLA-000D3 FW2K0 NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ1T6HBJRAD3 Y7D7D 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ6T4HALAAD3 91FXC 5CM3G 2.5.0 6.4 TB Cache, Capacity
2.2.2.2 - Azure Local Support Matrix for 16G (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-660 Windows Server 2025 Datacenter Azure Stack HCI-24H2
MC-660 Azure Stack HCI-24H2
MC-760 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP GPMNW 2.8.2 AX-660 AX-760 MC-660 MC-760 NA
W23G7 2.7.5
Chipset driver for 16G Intel platforms Driver DUP R40PW 10.1.19928.8615 AX-660 AX-760 MC-660 MC-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC9 with Lifecycle Controller Firmware DUP KYWDC 7.20.80.50 AX-660 AX-760 MC-660 MC-760 NA
Expander Storage Backplane Firmware DUP J9JW2 1.61 AX-760 MC-760 NA
NVMe Switch Storage Backplane Firmware DUP R39FM 3.33 AX-760 MC-760 NA
Non-expander Storage Backplane Firmware DUP 58MWX 7.2 AX-760 MC-760 NA
Non-expander Storage Backplane Firmware DUP 9T7YG 7.2 AX-660 MC-660 NA
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-660 AX-760 MC-660 MC-760 NA
CPLD Firmware DUP XJG0V 1.2.7 AX-660 AX-760 MC-660 MC-760 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card 5NN70 Management N/A 5V215 23.31.1 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Broadcom 57504 Quad Port 10/25GbE, SFP28 Adapter 3Y64D Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14
Broadcom 57416 Dual Port 10Gb, Base-T, PCIe Adapter, Full Height 3TM39 Management Compute (Premium) N/A HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, PCIe Low Profile NC5VD
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 RN1M5
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760 MC-660 MC-760
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter DN78C
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-760 MC-760
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 553.62 Yes AX-760 MC-760 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 553.62 Yes AX-660 AX-760 MC-660 MC-760 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 553.62 Yes AX-660 AX-760 MC-660 MC-760 Azure Stack HCI-24H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 553.62 Yes AX-760 MC-760 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 553.62 Yes AX-660 AX-760 MC-660 MC-760 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 553.62 Yes AX-660 AX-760 MC-660 MC-760 Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-760 MC-760 Azure Stack HCI-24H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 95.02.66.00.02 553.62 Yes AX-760 MC-760 Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 WW56V C6MVR 2.1.13.2037 Inbox Inbox AX-660 AX-760 MC-660 MC760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-660 AX-760 MC-660 MC760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-660 AX-760 MC-660 MC760 Windows Server 2022 Datacenter
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBA960TDZ PRV6C N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG960TDZ 0V8F7 N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X YJG7C 1.3.1 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBAXXXTFR PH7J6 JHKXR 1.4.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6480HFLUAD3 C82V9 FTVJG 1.0.1 480 GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6960HFLBAD3 8M3JN FTVJG 1.0.1 960 GB Boot
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SDA400NY 9VN79 99TKP EP02 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 GY6MD US09 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG F95CX EL02 8 TB Capacity
HDD SAS 3.5 Read Intensive Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA Seagate CimarronBP(EWP) DL4000NM019B F7DTR M7PKX LBW4 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 20Y02 EM06 12 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST12000NM007H FN7VR 3VY0D SWS9 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA16TEY MXC46 20Y02 EM06 16 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST16000NM007H R0G8W C50CR SYS9 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SCA20TEY NT45N 0H3CX EN04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-D PR2 WUH722020BL5200 1D4CR XRFX3 VS19 20 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST20000NM007H R5KP7 C50CR SYS9 20 TB Capacity
HDD SAS 3.5 NA WD London DP WUH722420AL5200 MTTCF FN2N1 YS01 20 TB Capacity
HDD SAS 3.5 NA WD Paris-CP WUH722012CL5200 849H4 VK0PK AS05 12 TB Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 3GHD6 HG61 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 T3HX9 HJ64 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L31T9HELAAD3 PTD53 D5D3W HL58 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK1T9TGA-1BC1ZABDA KXNX5 RJ0WY K003 1.92TB Capacity
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 3GHD6 HG61 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W T3HX9 HJ64 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L33T8HELAAD3 D7V89 D5D3W HL58 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84TB Capacity
SSD SATA 2.5 Mixed Use Intel S4620 SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897a MZ7L31T9HENAAD3 GR4WN V5XNY HK58 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M VRG4Y HH64 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK1T9TGB-1BC1ZABDA XRXX2 RJ0WY K003 1.92TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 71KRG 1.2.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 71KRG 1.2.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 71KRG 1.2.0 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 71KRG 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 71KRG 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 71KRG 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 71KRG 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS960GECTX088N WR2FG T1XKD 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG960G YNGYD HV8P1 2.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC960TFR KXT48 TVCWT 1.4.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC960TGP G7NCH 5F07C 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL2960HCJRAD3 6HYWM XMFKX 1.1.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 71KRG 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR1T9HBJRAD3 WPR17 5V3P7 2.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL21T9H TGYF5 XMFKX 1.1.1 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC1T9TFR JH61J TVCWT 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC1T9TGP M7RHM 5F07C 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS1T9GEETX099N 147DR TDGKY 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC3T8TFR NDK2D TVCWT 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG3T84 RFYP9 K6597 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS3T8GECTX088N V6WP5 T1XKD 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL23T8HCLSAD3 P7G03 XMFKX 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC3T8TGP GT3F3 5F07C 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL27T6HBLAAD3 30FX3 XMFKX 1.1.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC7T6TFR 91KYJ TVCWT 1.4.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC7T6TGP RTJFW 5F07C 1.2.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS960GEETX099N 26WJ0 TDGKY 1.1.0 960GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO1T9HCJR-00AD3 G64N5 V7V0K 1.0.0 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS3T8GEETX099N 2V97V TDGKY 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO15THBLA-00AD3 VPWMR V7V0K 1.0.0 15.36TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 NYPRM FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
2.2.2.3 - Azure Local Support Matrix for 45n0c (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Model Supported Operating System
AX-4510c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
MC-4510c Azure Stack HCI-24H2
MC-4520c Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP FP79X 1.21.1 AX-4510c AX-4520c MC-4510c MC-4520c NA
0YP04 1.19.1
iDRAC9 with Lifecycle Controller Firmware DUP KYWDC 7.20.80.50 AX-4510c AX-4520c MC-4510c MC-4520c NA
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-4510c AX-4520c MC-4510c MC-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-4510c AX-4520c MC-4510c MC-4520c NA
Chassis Manager Firmware DUP WC84H 5 AX-4510c AX-4520c MC-4510c MC-4520c NA
CPLD Firmware DUP G1YRC 1.0.5 AX-4510c AX-4520c MC-4510c MC-4520c NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 1.10.3 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c MC-4520c
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4510c AX-4520c MC-4510c MC-4520c
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c MC-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c MC-4520c
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c MC-4520c
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-4520c MC-4520c Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-4520c MC-4520c Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 M88HH 67GHR 2.1.13.2037 Inbox AX-4510c AX-4520c MC-4510c MC-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG1T9TDZ G18YX N71F4 1.6.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG3T8TDZ 2RN2N N71F4 1.6.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE8030 HFS800GDC8X088N 31XDY R2TTT 1.3.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Micron 7450 MTFDKBA800TFS F9MKX JHKXR 1.4.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE9030 HFS800GDJ8X167N FYWN9 9GH86 1.2.1 800GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X YJG7C 1.3.1 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBA960TFR PH7J6 JHKXR 1.4.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG1T9TFR J927V JHKXR 1.4.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS1T9GDE0X088N MY5M4 19H08 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG3T8TFR 5FP33 JHKXR 1.4.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS3T8GDE0X088N 5JR5H 19H08 1.1.0 3.84TB Capacity
2.2.2.4 - Azure Local Golden Images (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Stack HCI OS :
OS build 26100.xxxx (24H2)
Azure Local Golden Images for Solution versions 12.2510.1002.* - 12.2603.1002.* with Dell SBE 4.2.2512.*
Azure Stack HCI OS Golden Image for Azure Local
Platform
Use
Instance Expansion and Machine Repair Notes
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2512 drivers, and Dell SBE 4.2.2512.1616 for AX-760, AX-660, AX-4510c, AX-4520c, APEX MC-760, APEX MC-660, APEX MC-4510c, and APEX MC-4520c
AX-760 AX-660 AX-4510c AX-4520c APEX MC-760 APEX MC-660 APEX MC-4510c APEX MC-4520c
Deploy Instance Expansion (Add-Server) Machine Repair
Use with Azure Local instances running Solution version 12.*.1002.* Specify Azure Local instance Solution version when running Arc registration using:Invoke-AzStackHciArcInitialization -TargetSolutionVersion [Solution Version]
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2512 drivers, and Dell SBE 4.2.2512.1514 for AX-750 and AX-650
AX-750 AX-650
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2512 drivers, and Dell SBE 4.2.2512.1514 for AX-7525 and AX-6515
AX-7525 AX-6515
Azure Stack HCI 24H2 with OS customization 12.2510.0.3165, Dell 2512 drivers, and Dell SBE 4.2.2512.1403 for AX-740xd and AX-640
AX-640 AX-740xd
2.2.2.5 - Azure Local Dell Solution Builder Extensions Release Notes (Dell 2512)
Overview
Solution Builder Extensions (SBE) for Azure Local. Firmware, Driver, and WDAC Supplemental policy for lifecycle management for Azure Local instances running on Dell AX servers.
Important Caveats
NVIDIA ConnectX NIC resets have been observed by customers under certain workloads. Affected driver version 25.1.26647.0 and corresponding firmware was introduced in the SBE 4.2.2506.n. SBE 4.2.2509.n and 4.2.2512.n will downgrade the NVIDIA ConnectX driver to version 24.4.26429.0, but the ConnectX firmware must be manually downgraded prior to installing SBE 4.2.2512.n.
For details and instructions, see KB000376360 .
Dell Micron 7450 and 7500 NVMe SSDs occasionally enter a panic state. For details and instructions, see KB000368482 . From the SBE table above, find the version relevant to your product and install the SBE with updated firmware that resolves the defect for the Micron 7450 and 7500 drives.
SBE versions 4.2.2512.1616 and 4.2.2512.1514 include the same BIOS version as previously released SBE versions 4.2.2509.1625 and 4.1.2509.1516 for the 16G, 45n0c, AX-650, and AX-750. New Azure Local instance deployments may have newer BIOS versions as listed in the Dell 2512 support matrix . The installation of SBE 4.2.2512.n will not downgrade the BIOS version in this case. The supported BIOS versions are listed in the Dell 2512 support matrix .
New for This Release
SBE 4.2.2512.1616
Driver and Firmware 2512 Update
Added server component health checks
Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
Added support for APEX MC branded nodes
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.*.1001.* or 12.*.1002.*
SBE 4.2.2512.1514
Driver and Firmware 2512 Update
Added server component health checks
Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.*.1001.* or 12.*.1002.*
SBE 4.2.2512.1403
Driver and Firmware 2512 Update
Added server component health checks
Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
To install this SBE version, Azure Local instances that are already deployed must be running solution version 12.*.1001.* or 12.*.1002.*
Prerequisites
Update Firmware and Drivers Prior to Azure Local Instance Deployment
Drivers and firmware need to be installed on the servers that will be the instance members prior to deployment from the Azure Portal or using an ARM Template. This requirement is independent of the installation of the SBE. The machines imaged with Dell provided golden image will include the required Dell provided Out-of-Box drivers, but the firmware versions must still be validated and possibly updated prior to the instance deployment. The most current driver and firmware versions listed in the support matrix are recommended.
The Azure Local support matrix for Dell AX servers can be found here, Support Matrix | Solutions for Microsoft Azure .
iDRAC Access from Host OS
The iDRAC pass-through NIC must be enabled and have an IP address assigned to it. iDRAC pass-through NIC is enabled by default and has an APIPA (Automatic Private IP Addressing) IP address assigned. This IP address must be accessible by the iDRAC NIC Remote NDIS Compatible Device in the host operating system. This is a dedicated link to the host OS and cannot be accessed outside the host OS.
iDRAC access health checks are introduced starting with the December 2024 SBE releases. These health checks verify that the required iDRAC access has been implemented on each server that will be an instance member. The iDRAC access health checks run automatically as part of the standard built-in SBE health checks. These health checks must complete successfully for the SBE installation to proceed. Failure remediation instructions are provided in case the health check fails.
Manual iDRAC Access Verification
The following procedures provide a manual method for verifying the required iDRAC access. The iDRAC access health checks provide automated and more comprehensive verification method.
Example iDRAC Pass-through settings
The iDRAC NIC Remote NDIS Compatible Device in the host operating system is used by the SBE CAU plug-in to update firmware. This NIC must be enabled and have an IP address assigned to it. By default, this NIC is enabled and has an APIPA IP address assigned to it that can access the iDRAC pass-through IP address. DHCP client should not be disabled on this NIC.
This is a dedicated link to iDRAC from the host OS and cannot be accessed outside the host OS.
The IP address can be obtained using the following PowerShell command:
Get-NetAdapter -InterfaceDescription "Remote NDIS Compatible Device" | Get-NetIPAddress -AddressFamily IPv4 | Select-Object -Property IPAddress
Example:
IPAddress
---------
169.254.0.2
Azure Local instances using Non-Transparent, Unauthenticated Network Proxy
Azure Local instances using non-transparent, unauthenticated network proxy must have the iDRAC pass-through IP address in the network proxy exclusion list. For information on how to configure the non-transparent, unauthenticated network proxy see, Configure proxy settings for Azure Local .
The following example shows how to configure the APIPA IP address range 169.254.0.0/16 to be in the network proxy exclusion list.
$NoProxy = "localhost,127.0.0.1,.svc,10.0.0.0/8,172.16.0.0/12,192.168.0.0/16,.contoso.com,node1,node2,ClusterName,169.254.0.0/16"
[Environment]::SetEnvironmentVariable("NO_PROXY", $NoProxy, "Machine")
Download Connector – Automated download of future SBE release
Overview
Download Connector is a component in the SBE (Solutions Builder Extensions) that automates the downloading of new SBE bundles as they become available for your cluster. Once an SBE that includes the Download Connector is installed on your cluster, manually downloading and importing follow-on SBE version is no longer required. The update service will automate the downloading of the next available SBE for your Azure Local instance in a similar manner to how the download of the solution upgrade is automated. The Download Connector is part of the SBE version 4.1.2505.1501 and newer.
SBE versions that include the Download Connector also include system and update health checks that proactively verify the ability of the Download Connector to access the required remote resource when it comes time to download the next SBE for your cluster. System health checks are run once per day and update health checks are run at the initial phase of the update process.
Firewall Requirements
The SBE Download Connector running in the Azure Local instance needs to periodically connect to the internet resources to download SBE bundles for your cluster. The following outbound connectivity is required.
Endpoint Description
Endpoint URL
Port
SBE bundle download
dl.dell.com/*
443
SBE download catalog
downloads.dell.com/filestore/Prod/SbeDownloadCatalog/AX_SBE_Download_Catalog.xml
443
SBE download catalog redirection
aka.ms/DellAzureLocalSBEDownloadCatalog
443
Digicert Certificate Revocation Status
http://crl3.digicert.com/*
80
Digicert Certificate Revocation Status
http://crl4.digicert.com/*
80
Installation
Download and Extract
CAUTION
Steps 3 and 4 must be completed to ensure that the latest SBE Discovery manifest is used.
SBE bundle zip file has the naming convention Bundle_SBE_Dell_AS-HCI-AX-GenerationNumber_VersionNumber.zip.
Download the SBE bundle zip file for your Dell AX server generation using the download link above. The SBE bundles are specific to the AX 14G platforms, AX 15G platforms, and AX 16G platforms
Extract the three SBE files from the SBE bundle zip file. There are two xml files and one zip file. Example:
SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.xml
SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.zip
SBE_Discovery_Dell.xml
Navigate to https://aka.ms/AzureStackSBEUpdate/DellEMC and press Ctrl + S to download the SBE_Discovery_Dell.xml file
Replace the SBE_Discovery_Dell.xml file that was in the SBE bundle zip with the file downloaded in step 3
There are two options for installing the SBE package. The SBE package can be installed as part of instance creation or imported after instance creation is successfully completed. The importing method is also used to update the SBE to a newer version when the currently running SBE does not include Download Connector capability.
Automated Download and Extraction
SBE release starting with 4.1.2505.1501 and newer include the Download Connector that automates downloading and extracting the SBE. Manual download and SBE bundle extraction are unnecessary when an SBE with this capability is already installed on the Azure Local instance.
Installing SBE as Part of Instance Creation
Starting with June 2025 Dell golden image release, the SBE files are included in the golden image and already placed in the C:\SBE directory. The following 3 steps do not need to be performed.
On each server that will be an instance member, create the following directory: C:\SBE
Copy the three SBE files to the directory C:\SBE on each server that will be an instance member
Proceed to deploying the instance from the Azure Portal or an ARM template
Importing the SBE After Successful Azure Local Instance Creation
Create a directory on a cluster shared volume (CSV) for sideloading the SBE, e.g., C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600
Copy the three extracted SBE files to this directory
Load the SBE files by running the following command with the path to the directory that holds the three extracted SBE files
Add-SolutionUpdate -SourceFolder "C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600"
Check the state of the SBE that was just added. The state needs to be Ready.
Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE"
Verify that the Azure Local instance is in a healthy state and is ready for the SBE installation by running the following commands on one of the Azure Local instance machines:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate -PrepareOnly
Wait for the health check to complete. The solution update state will report HealthChecking while the health check is in progress.
After the health check completes, run the following command if the solution update state reports HealthCheckFailed:
$Result = (Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"}).HealthCheckResult
$Result | Where-Object { ($_.Status -ne "SUCCESS" -and $_.Severity -eq "CRITICAL" ) } | Format-List -Property Title, Status, Severity, Description, Remediation, TargetResourceName, TargetResourceType
All tests with Critical severity must have the Success status before continuing to the next step.
Start the SBE installation by running the following command:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate
The SBE installation progress can be checked by running the following command:
Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE" | Format-List -Property ResourceID, Description, State, SBEVersion, UpdateStateProperties, HealthState
For more information see, Update Azure Local via PowerShell .
Known Issues
SBE Installation May Fail With Driver CAU Plug-In Error When Attempting to Delete NVIDIA ConnectX Driver That Is Not Installed
Description
The failure occurs in the driver CAU plug-in when driver downgrade option is specified for a given driver and the driver is not found in the driver store. This failure occurs in the following conditions:
Cluster nodes were not imaged using Dell provided Azure Local golden image
NVIDIA ConnectX NIC is not installed in the cluster nodes
A previous version of an AX SBE is not installed
Workaround
Run the following script on each instance machine after completing step 5 “Verify that the Azure Local instance is in a healthy state and is ready for the SBE installation ” in the Importing the SBE After Successful Azure Local Instance Creation section or when the failure is encountered during the SBE installation.
#Run this script on each node in the cluster.
$ConnectXDriverFileName = "mlx5.inf"
$InstalledConnectXDriver = Get-WindowsDriver -Online | Where-Object -Property OriginalFileName -IMatch $ConnectXDriverFileName
if (-not $InstalledConnectXDriver) {
Write-Output "Out-of-Box NVIDIA ConnectX driver not found on node: $($env:COMPUTERNAME)"
Write-Output "Checking SBE installation status on cluster: $((Get-Cluster).Name)"
$SBEWithPackagePaths = Get-SolutionUpdate | Where-Object { ($_.PackageType -eq "SBE") -and ($_.PackagePath -ne $null) -and ($_.PackagePath -notlike "https*") }
if ($SBEWithPackagePaths) {
$SBEPackagePath = ($SBEWithPackagePaths | Select-Object -First 1).PackagePath
$MlxDriverInfBaseFilePath = Join-Path -Path $SBEPackagePath -ChildPath "DriversGE\Network\Mellanox"
$MlxDriverInfFilePath = Get-ChildItem -Path $MlxDriverInfBaseFilePath -Filter $ConnectXDriverFileName -Recurse
Write-Output "SBE payload NVIDIA ConnectX driver file path: $($MlxDriverInfFilePath.FullName)"
if (Test-Path -Path $MlxDriverInfFilePath.FullName) {
Write-Output "Importing NVIDIA ConnectX driver..."
pnputil.exe /add-driver $MlxDriverInfFilePath.FullName /install
if (Get-WindowsDriver -Online | Where-Object -Property OriginalFileName -IMatch $ConnectXDriverFileName) {
Write-Output "NVIDIA ConnectX driver has been added to the driver store"
} else {
Write-Output "NVIDIA ConnectX driver is still not found in the driver store on node: $($env:COMPUTERNAME)"
}
} else {
Write-Output "Failed to resolve path: $($MlxDriverInfFilePath.FullName)"
}
} else {
Write-Output "SBE package path not found"
}
} else {
Write-Output "Found NVIDIA ConnectX driver version: $($InstalledConnectXDriver.Version) in the driver store"
Write-Output "No further action is required on this node"
}
Background
This SBE installation failure is resolved in the Azure Local Solution version 12.2512.1002.* and newer.
The driver CAU plug-in driver downgrade option is used in special cases. Currently, it is only used in the case of NVIDIA ConnectX NIC driver.
Partially Installed SBE Version 4.0.0.0 When SBE Is Installed as Part of Cluster Deployment
Description
Get-SolutionUpdateEnvironment reports partially installed SBE when installing the SBE as part of Azure Local instance deployment. SBE version 4.0.0.0 indicates a partially installed Solution Builder Extension (SBE).
Get-SolutionUpdateEnvironment
ResourceId : redmond
SbeFamily : AX-16G-45n0c
HardwareModel : AX-760
LastChecked : 08/01/2026 14:09:31
PackageVersions : {Solution: 12.2512.1002.16, Services: 10.2512.0.9, Platform: 12.2512.0.3021, SBE: 4.0.0.0}
CurrentVersion : 12.2512.1002.16
CurrentSbeVersion : 4.0.0.0
LastUpdated :
State : UpdateAvailable
HealthState : Success
HealthCheckResult : {Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary...}
HealthCheckDate : 07/01/2026 17:50:07
AdditionalData : {[SBEAdditionalData, Solution Builder extension is partially installed. Please install the latest Solution Builder Extension provided by your hardware vendor. For more information, see https://aka.ms/SBE.]}
Workaround
Reinstall the same SBE version using the SBE import method or automated download method after Azure Local instance deployment successfully completes.
Background
The SBE driver CAU plug-in expects all drivers and firmware in the SBE payload to be installed on the server during or prior to deployment. However, some of the drivers in the SBE payload may not apply to the server model or components in the server model. Microsoft is aware of this limitation and is working to resolve this issue in a future release.
The partially installed SBE issue, can also occur if a component firmware version installed on the server is different than what is in the SBE payload. The SBE cannot update firmware or drivers during Azure Local instance deployment.
SBE installation will not downgrade drivers that have a newer version than the same driver in the SBE payload
Dell supports the driver and firmware versions listed here, Support Matrix | Solutions for Microsoft Azure .
Description
The SBE driver CAU plug-in will not attempt to downgrade installed drivers that are higher version than the ones in its payload unless otherwise specified by Dell.
Description
SBE installation fails because the driver CAU plug-in in the SBE is unable to update the AMD DRTM driver to a newer version that is in the SBE payload. The AMD DRTM driver is one of the AMD Chipset drivers in the SBE package. The AMD DRTM driver update fails because the AMD DRTM setting was originally enabled but later disabled.
Workaround
Verify that the AMD DRTM BIOS setting is on. Turn back on the AMD DRTM setting if it is off.
The DRTM option is in the BIOS configuration: System Security -> TPM Advanced Settings -> AMD DRTM
Make sure to suspend and drain the Azure Local cluster node prior to rebooting the node. Make sure that BitLocker protection is disabled for the boot volume on the cluster node before making BIOS configuration changes. Disable BitLocker if it is enabled for the boot volume C:\ prior to rebooting the server for the BIOS changes to take effect. Reenable BitLocker for the boot drive after the server successfully reboots.
Background
AMD DRTM is an advanced security feature that is available on modern AMD CPUs and is used to protect the secure boot enclaves. The AMD DRTM setting is enabled by default on AX servers with AMD CPUs that support the DRTM feature. AMD DRTM should not be disabled.
Previous Releases
2.2.3 - Azure Local Support Matrix (Dell 2509)
2.2.3.1 - Azure Local Support Matrix for 14G-15G (Dell 2509)
NOTE
The Dell AX System for Azure Local AX-640, AX-740xd, AX-650, AX-750, AX-7525, and AX-6515 now supports upgrades from Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2. The cluster must have firmware and drivers updated to the levels listed in this support matrix prior to starting the upgrade process.
Please see the following knowledge base article for procedure details and known issues:
Upgrade Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2
Model Supported Operating System
AX-640 Windows Server 2022 Datacenter Azure Stack HCI-23H2 (Upgrade only) Azure Stack HCI-24H2
AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 (Upgrade only) Azure Stack HCI-24H2
AX-6515 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-650 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP T4VCN 2.24.0 AX-640 AX-740xd NA
BIOS Firmware DUP H55DC 2.19.0 AX-6515 NA
BIOS Firmware DUP NTCJ8 2.19.0 AX-7525 NA
BIOS Firmware DUP 12YN5 1.18.1 AX-650 AX-750 NA
iDRAC9 with Lifecycle Controller Firmware DUP RVDDR 7.00.00.181 AX-640 AX-740xd NA
iDRAC9 with Lifecycle Controller Firmware DUP 6CKFT 7.20.60.50 AX-6515 AX-7525 AX-650 AX-750 NA
Non-expander Storage Backplane Firmware DUP VV85D 4.35 AX-6515 AX-640 AX-740xd NA
Non-expander Storage Backplane Firmware DUP KW60H 7.1 AX-7525 AX-750 NA
Non-expander Storage Backplane Firmware DUP X3JNV 7.1 AX-650 NA
NVMe Switch Storage Backplane Firmware DUP 5XJWN 1.05 AX-750 NA
Expander Storage Backplane Firmware DUP H9PV3 1.2 AX-7525 AX-750 NA
Expander Storage Backplane Firmware DUP 60K1J 2.52 AX-640 AX-740xd NA
Expander Storage Backplane Firmware DUP 2F90T 2.46 AX-6515 NA
Chipset driver for 14G Intel platforms Driver DUP 4DDMJ 10.1.19913.8607 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Chipset driver for 15G AMD platforms Driver DUP DRN52 6.11.12.245 AX-6515 AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-650 AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-640 AX-740xd AX-6515 AX-7525 AX-650 AX-750 NA
CPLD Firmware DUP 9N4DH 1.0.6 AX-640 NA
CPLD Firmware DUP G65GH 1.1.4 AX-740xd NA
CPLD Firmware DUP 79XGF 1.0.7 AX-6515 NA
CPLD Firmware DUP 4NMC7 1.2.0 AX-7525 NA
CPLD Firmware DUP FCTDF 1.1.1 AX-650 AX-750 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1GbE On-Board LOM JDN4V Management NA 9GMFK 23.31.0 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-650
5V215 23.31.1
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A 9GMFK 23.31.0 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515
5V215 23.31.1
Broadcom 5720 Dual Port 1GbE On-Board LOM 6V45N Management NA 9GMFK 23.31.0 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-750
5V215 23.31.1
Broadcom 5720 Dual Port 1GbE On-Board LOM 74H08 Management NA 9GMFK 23.31.0 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525
5V215 23.31.1
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-640 AX-740xd
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP 20NJD Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC R887V Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 R640 Storage Spaces Direct RN
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH MRT0D Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-740xd
Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 YGRX3
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH 71C1T Management Compute (Premium) Storage (Premium) RoCEv2 XY16R 16.35.30.06 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP 9FTMY
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 F7V1F
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 JGWVY
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH TDNNT
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP V5DG9
NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 DN78C Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-650 AX-750 AX-7525
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC 165T0 Management N/A 9KYR0 16.20.00 VYWY1 36.20.02 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic 57800 2x10Gb BT + 2x1Gb BT NDC G8RPD
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T and Dual Port 1GbE BASE-T, rNDC 0D1WT Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC X1TD1 Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC XVVY1
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP 415DX Management Compute (Premium) Storage (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd
QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC 4KF8J
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH 51GRM
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A10 NVIDIA NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 6KNWW 94.02.5C.00.04 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU 8F04V 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU W3C1G 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-23H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 RV08M 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-23H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-750 AX-7525 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU HCKJM 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU 7PH29 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-23H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-S1 2MFVD 3P39V 2.5.13.3024 7004G 1.2.0.1055 AX-6515 AX-7525 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
BOSS-S2 FGNRW TTR5R 2.5.13.4009 7004G 1.2.0.1055 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 Inbox 2.51.27.80 AX-640 AX-740XD AX-6515 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 Inbox 2.51.27.80 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-23H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA M.2 NA Intel S3520 SSDSC2BB120G7R 394XT CHJGV DL43 120 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV240TCB TC2RP H6NHD E013 240 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV480TCB GPGC0 H6NHD E013 480 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV240TDU T2GFX KT63Y J008 240 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV480TDS 7RKD7 KT63Y J008 480 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville RR S4520 SSDSCKKB240GZR CM88M VJPKG DL7C 240 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville S4510 SSDSCKKB240G8R DMC15 Y1P10 DL6R 240 GB Boot
SSD SATA M.2 Read Intensive Micron 5400 MTFDDAV240TGC-1BC1ZABDA T4MJ3 RJ0WY K003 240 GB Boot
SAS 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 2.5 NA Seagate Avenger ST2000NX0463 TMVN7 GW3V7 NT32 2 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt DL2400MM0159 RWR8F DRHV4 ST5J 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ST2400MM0159 36YG1 7N5DH ST7G 2.4 TB Capacity
HDD SAS 2.5 NA Toshiba AL15SE AL15SEB24EQY F9NWJ J11N2 EF09 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ServoBP BL2400MM0159 1D0F5 00P56 SBSA 2.4TB Capacity
SATA 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 2.5 NA Seagate Avenger ST2000NX0423 VR92X GMW4P NB33 2 TB Capacity
SATA 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 3.5 NA HGST Aries K Plus HUS726020ALA610 8NP2N KH52Y KV46 2 TB Capacity
HDD SATA 3.5 NA HGST Aries K Plus HUS726040ALA610 61FFW KH52Y KV46 4 TB Capacity
HDD SATA 3.5 NA HGST Rainier MLK HUS722T2TALA600 V9H6C V3DJM MU03 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA200NY NPVM6 6D4CG FK5D 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA400NY 95M6K 6D4CG FK5D 4 TB Capacity
HDD SATA 3.5 NA Seagate Nemo ST2000NM0018-2F3130 W8FW5 CMK5N EA04 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST2000NM0145-2DC104 WG9R0 M5GJ1 DB34 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST4000NM0265-2DC107 MWHY9 M5GJ1 DB34 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-A HUS726T4TALA6L0 YH3T9 HV5HH PV09 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-AP HUS728T8TALE6L0 1WMVC T0RX4 RT09 8 TB Capacity
HDD SATA 3.5 NA HGST Libra HE10 HUH721008ALE600 KRV2W H12N2 LT21 8 TB Capacity
HDD SATA 3.5 NA Seagate Makara Plus ST8000NM0205-2FF112 92MDW MR6RH PB53 8 TB Capacity
HDD SATA 3.5 NA Toshiba MG06 MG06ACA800EY 9X09C PT7D8 GA09 8 TB Capacity
HDD SATA 3.5 NA HGST Leo-A He12 HUH721212ALE600 T2YHT JCYF6 NT11 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG07 MG07ACA12TEY 753F0 0942Y GB03 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AC MG08ACA16TEY HPGJ4 WTNDC GC04 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA400NY W2M9N F73C5 GD05 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST4000NM016A-2HZ130 XPJ47 RWK48 CAJD 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST8000NM012A-2KE131 F4JXT TF6TF CALF 8 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST12000NM002J-2TY133 KTJTY 4MPD6 PALB 12 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST16000NM002J-2TW133 JWV1P 4MPD6 PALB 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA800EY T5XR5 GP6NC GE01 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST4000NM018B-2TF130 6KR2M T04YV LC0A 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Aries K Plus HUS726020ALS210 VH6FW 8W7XP KU46 2 TB Capacity
HDD SAS 3.5 NA HGST Aries K Plus HUS726040ALS210 X4FKY 8W7XP KU46 4 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA20ENY HHX14 RG9MK EG03 2 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA40ENY 1MVTT RG9MK EG03 4 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST2000NM0155 7RCGV XKD4M DT34 2 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST4000NM0295 5JH5X XKD4M DT34 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA HGST Libra HE10 HUH721008AL5200 KRDKK MGW91 LS21 8 TB Capacity
HDD SAS 3.5 NA Seagate Makara Plus ST8000NM0185 M40TH 6421F PT55 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA Seagate Mobula BP ST12000NM0158 YMN53 VTX9C RSL5 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY DK7C9 NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY KFJ7G NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 8MG73 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 4N7V0 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 24HF9 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Seagate Evans ST16000NM010G CNXPV 3YP54 ESL9 16 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST4000NM017A KRM6X J12RT CSJA 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST8000NM014A 0N660 0HG6Y CSLE 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Seagate EvansBP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
SATA 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF8800CCSE VCRY6 H3XHN DACB 800 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF81D60CSE DMF5Y H3XHN DACB 1.6 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK960TDT XMWMK KT63Y J008 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK3T8TGB-1BC1ZABDA 34JK8 JTW3W K403 3.84 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM960HMJP0D3 DD4G0 97D8J GD57 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM1T9HMJP0D3 K5P0T 97D8J GD57 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH960HAJR0D3 YDHYX 3J3JR HF58 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH1T9HAJR0D3 71K37 3J3JR HF58 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG960G7R TR3MY V141M DL5C 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG019T7R MWKF2 V141M DL5C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG960G8R X31G3 4DW70 DL6B 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R F8N2K 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R 55J8H 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK960TDN HY1F8 W2X8N F005 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK1T9TDN XKF5Y W2X8N F005 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE960G XW4D1 W0YR1 DBC4 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE1T92 0DXJ7 W0YR1 DBC4 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS960G3E2X149N G162V 4T2FN DG00 960GB Cache,Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG960GZR 8MHYH VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG960GZR DYMD0 VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L3960HBLTAD3 96KT6 Y4WVW HH62 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92 TB Cache,Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB960GZR F6H8H VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB960GZR 5M8Y4 VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5200 MTFDDAK1T9TDD VJ36D W2X8N F005 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 SED MTFDDAK3T8TGA-1BC16ABDA 2DXDK JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE1T92 919J7 W0YR1 DBC4 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE3T84 8PYG5 W0YR1 DBC4 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 107CV HG60 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH1T9HMLT0D3 Y24T6 93P7P HE59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS1T9G32FEH-7A10A 0XMV9 3DTV4 DE08 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB019T8R 33R2T 4DW70 DL6B 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB019T7R XCN15 V141M DL5C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB038T7R 3RRN8 V141M DL5C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB038T8R 1RHK2 4DW70 DL6B 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH3T8HMLT0D3 FYP5F 93P7P HE59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 107CV HG60 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS3T8G32FEH-7410A D6C0R 3DTV4 DE08 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA10A 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92 TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG800G H6GCD NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG1T60 5GDXH NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G JTKH5 NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 GD3N0 NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG3T20 NKM7P NGPR2 BA48 3.2 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG6T40 6NW3J NGPR2 BA48 6.4 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB080Y CN3JH 1DJXX AS10 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB096Y 503M7 1DJXX AS10 960 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB160Y GVTYD 1DJXX AS10 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB192Y V0K7V 1DJXX AS10 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB384Y 3DDFT 1DJXX AS10 3.84 TB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG800G DHRVV CPP97 B02A 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG1T60 W9G88 CPP97 B02A 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT800HBHQ0D3 GW8T1 VJY6V DWA4 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT1T6HBJR0D3 3TCV6 VJY6V DWA4 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645 MZILT1T6HAJQ0D3 DR0HX 4PPHJ DWF8 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6480BSS200 6VJC9 8W5WF G138 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6416BSS200 6NF96 8W5WF G138 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG960G WFGTH CPP97 B02A 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG1T92 2WVYG CPP97 B02A 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG3T84 91W3V CPP97 B02A 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG960G WMWKG 6DH0W BD48 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG1T92 DHWH5 6DH0W BD48 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG3T84 81H9C 6DH0W BD48 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG800G 81G77 57MM2 C40E 800GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG1T60 G4NY4 57MM2 C40E 1.6TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T20 RGP9J 57MM2 C40E 3.2TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T84 FMP6K 57MM2 C40E 3.84TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG960G J92FY 6DH0W BD48 960 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG1T92 1081V 6DH0W BD48 1.92 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG3T84 MD4YN 6DH0W BD48 3.84 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 CHJJJ NGPR2 BA48 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Plus WUSTR6416ASS200 8W6HC 7HYHH K968 1.6 TB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1519ASS200 5ND33 7HYHH K968 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1538ASS200 YW17N 7HYHH K968 3.84 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA119BSS200 02X38 8W5WF G138 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA138BSS200 FP1KF 8W5WF G138 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT1T9HAJQ0D3 F0VFY J3RRK DSF8 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT3T8HALS0D3 X8F87 J3RRK DSF8 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT7T6HMLA0D3 RVYD5 J3RRK DSF8 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT1T9HBJR0D3 TMTW9 D7RNT DSA4 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT3T8HBLS0D3 CRNPH D7RNT DSA4 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS1T9HEJH0D3 086DD XNGNT DSLA 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS3T8HMLH0D3 JR1HP XNGNT DSLA 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT960HBHQ0D3 K74WN D7RNT DSA4 960 GB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT7T6HALA0D3 84C40 D7RNT DSA4 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 4CN85 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 H9TT5 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 PD02Y NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG1T92 7F2D1 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG3T84 FH1W9 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG1T92 H1P07 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG3T84 3VHY3 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG7T68 5T78C 6DH0W BD48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 VRTN9 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 2XVX2 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 YM0T1 NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG1T92 VGMCD 57MM2 C40E 1.92TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG3T84 YTVTF 57MM2 C40E 3.84TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG7T68 HCTYM 57MM2 C40E 7.68TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG1T92 TDNP7 CPP97 B02A 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG3T84 N85XX CPP97 B02A 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M4 PX05SRB384Y XCRDV 1DJXX AS10 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS3840SE70114 KXDCD NKGWD 3D03 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS1920SE70114 D4VFW NKGWD 3D03 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
Value SAS 2.5" SSD
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS1920SE70134 K9T53 G04C8 4S0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS3840SE70134 4KPKF G04C8 4S0C 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS7680SE70134 2THYF G04C8 4S0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Kioxia Phoenix RM5 KRM5XVUG3T84 X78JM NDG7N B710 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP ISE XS3840LE70154 NWGX3 NX13G 4D0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS960LE70095 2M1NG RRWVT CPE9 960GB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS1920LE70095 K805Y RRWVT CPE9 1.92TB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS3840LE70095 FT95M RRWVT CPE9 3.84TB Cache,Capacity
SSD VSAS 2.5 Read Intensive Kioxia Phoenix RM5 KRM5XRUG7T68 5XD2F NDG7N B710 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate Lange ISE XS7680SE70074 2PKRH H3VHX EC16 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP ISE XS7680SE70154 5KW0F NX13G 4D0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS960LE70134 2RDWT G04C8 4S0C 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS1920LE70134 N6DRV G04C8 4S0C 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS3840LE70134 YM9HP G04C8 4S0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG960G 42XXC 5WMK8 BJ07 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG1T92 N15JP 5WMK8 BJ07 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG3T84 FXYGR 5WMK8 BJ07 3.84 TB Cache, Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG1T92 1FGWG 5WMK8 BJ07 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG3T84 XNXD2 5WMK8 BJ07 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG7T68 5MHY8 5WMK8 BJ07 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG960G 05MT7 1YD58 CA0C 960 GB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG1T92 59XF2 1YD58 CA0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG3T84 M0JVN 1YD58 CA0C 3.84 TB Capacity
SSD vSAS 2.5 Read Intensive Kioxia RM7 KRM7VRUG7T68 D480G 1YD58 CA0C 7.68 TB Capacity
SSD vSAS 2.5 Read Intensive Seagate Cooper XS7680SE70145 1J46N RRWVT CPE9 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Write Intensive Intel Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF SSDPE21K375GAT 3DM57 HMRK7 E201DP38 375 GB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HEHP-000D3 JD6CH 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HMJP-000D3 JDMHM 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung
PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLS-000D3 Y3XT2 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HAJQ-000D3 4WDXY NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HAJQ-000D3 K60N7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLA-000D3 08NMX NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T7T F5P84 CR0HC QDV1DP17 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T7T MCV6J CR0HC QDV1DP17 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T8T 58V30 GD4X4 VDV1DP25 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T8T 2CN1T GD4X4 VDV1DP25 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF SSDPE2KE064T8T X27HY GD4X4 VDV1DP25 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use KIOXIA DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS KCM6FVUL1T60 G7N00 WJD95 3.1.7 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 1.6TB C9X5T CGXH7 1.2.4 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 3.2TB PRKTM CGXH7 1.2.4 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 8FYM9 1.4.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 8FYM9 1.4.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 8FYM9 1.4.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR1T6HBJRAD3 0MNMV 5V3P7 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG960G DRC9H T79D5 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG3T84 17C57 T79D5 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P4510 SSDPE2KX040T8T 5GMK0 GD4X4 VDV1DP25 4 TB Capacity
NVMe PCIe 2.5 Read Intensive KIOXIA DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS KCM6FRUL1T92 TXP72 WJD95 3.1.7 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX019T9T WPP9G CGXH7 1.2.4 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX038T9T KRT3G CGXH7 1.2.4 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX076T9T RNN67 CGXH7 1.2.4 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR15THALAAD3 182NW 5V3P7 2.5.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 8FYM9 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 8FYM9 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 8FYM9 1.4.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 NYPRM FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
NVMe Add-in Cards
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC MZPLL1T6HEHP-000D3 06V6M 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC MZPLL3T2HMLS-00003 C2KKH 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC MZPLL6T4HMLS-000D3 604N5 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC MZPLL1T6HAJQ-000D3 FTX2R NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC MZPLL3T2HAJQ-00005 73KJ7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC MZPLL6T4HMLA-000D3 FW2K0 NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ1T6HBJRAD3 Y7D7D 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ6T4HALAAD3 91FXC 5CM3G 2.5.0 6.4 TB Cache, Capacity
2.2.3.2 - Azure Local Support Matrix for 16G (Dell 2509)
Model Supported Operating System
AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-660 Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP W23G7 2.7.5 AX-660 AX-760 NA
Chipset driver for 16G Intel platforms Driver DUP R40PW 10.1.19928.8615 AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
iDRAC9 with Lifecycle Controller Firmware DUP 6CKFT 7.20.60.50 AX-660 AX-760 NA
Expander Storage Backplane Firmware DUP J9JW2 1.61 AX-760 NA
NVMe Switch Storage Backplane Firmware DUP R39FM 3.33 AX-760 NA
Non-expander Storage Backplane Firmware DUP GXH37 7.1 AX-760 NA
Non-expander Storage Backplane Firmware DUP 6Y9X7 7.1 AX-660 NA
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-660 AX-760 NA
CPLD Firmware DUP 503F0 1.2.6 AX-660 AX-760 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card 5NN70 Management N/A 9GMFK 23.31.0 JDV91 233.1.181.0 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
5V215 23.31.1
Broadcom 57504 Quad Port 10/25GbE, SFP28 Adapter 3Y64D Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 233.1.181.0 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter DN78C
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-760
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 553.62 Yes AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 553.62 Yes AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 95.02.66.00.02 553.62 Yes AX-760 Azure Stack HCI-23H2 Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 WW56V 677KY 2.1.13.2034 Inbox Inbox AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-660 AX-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-660 AX-760 Windows Server 2022 Datacenter Azure Stack HCI-23H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBA960TDZ PRV6C N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG960TDZ 0V8F7 N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X 88JVY 1.0.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBAXXXTFR PH7J6 JHKXR 1.4.0 960GB Boot
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6480HFLUAD3 C82V9 FTVJG 1.0.1 480 GB Boot
NVMe PCIe M.2 Read Intensive Samsung PM9D3a MZVL6960HFLBAD3 8M3JN FTVJG 1.0.1 960 GB Boot
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SDA400NY 9VN79 99TKP EP02 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 Read Intensive Seagate LongsPeak ST20000NM004D R3G03 WCTTD GS09 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA Seagate CimarronBP(EWP) DL4000NM019B F7DTR M7PKX LBW4 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST12000NM007H FN7VR 3VY0D SWS9 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA16TEY MXC46 8829H EM05 16 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST16000NM007H R0G8W C50CR SYS9 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SCA20TEY NT45N 0H3CX EN04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-D PR2 WUH722020BL5200 1D4CR XRFX3 VS19 20 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST20000NM007H R5KP7 C50CR SYS9 20 TB Capacity
HDD SAS 3.5 NA WD London DP WUH722420AL5200 MTTCF FN2N1 YS01 20 TB Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 107CV HG60 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L31T9HELAAD3 PTD53 NF72T HL56 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK1T9TGA-1BC1ZABDA KXNX5 RJ0WY K003 1.92TB Capacity
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 107CV HG60 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L33T8HELAAD3 D7V89 NF72T HL56 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84TB Capacity
SSD SATA 2.5 Mixed Use Intel S4620 SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897a MZ7L31T9HENAAD3 GR4WN KHC8M HK56 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK1T9TGB-1BC1ZABDA XRXX2 RJ0WY K003 1.92TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 K1JTM 2.0.3 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 K1JTM 2.0.3 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 K1JTM 2.0.3 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 K1JTM 2.0.3 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF K1JTM 2.0.3 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 K1JTM 2.0.3 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD K1JTM 2.0.3 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS960GECTX088N WR2FG T1XKD 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG960G YNGYD HV8P1 2.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC960TFR KXT48 TVCWT 1.4.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC960TGP G7NCH 5F07C 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL2960HCJRAD3 6HYWM XMFKX 1.1.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 28J8R 1.1.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR1T9HBJRAD3 WPR17 5V3P7 2.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL21T9H TGYF5 XMFKX 1.1.1 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC1T9TFR JH61J TVCWT 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC1T9TGP M7RHM 5F07C 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS1T9GEETX099N 147DR TDGKY 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC3T8TFR NDK2D TVCWT 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG3T84 RFYP9 K6597 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS3T8GECTX088N V6WP5 T1XKD 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL23T8HCLSAD3 P7G03 XMFKX 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC3T8TGP GT3F3 5F07C 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL27T6HBLAAD3 30FX3 XMFKX 1.1.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC7T6TFR 91KYJ TVCWT 1.4.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC7T6TGP RTJFW 5F07C 1.2.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS960GEETX099N 26WJ0 TDGKY 1.1.0 960GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO1T9HCJR-00AD3 G64N5 V7V0K 1.0.0 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS3T8GEETX099N 2V97V TDGKY 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO15THBLA-00AD3 VPWMR V7V0K 1.0.0 15.36TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL6960HFJA-00AD3 71Y2J X5N7N 1.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZVL61T9HBL1-00AD3 NYPRM FTVJG 1.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL63T8HFLT-00AD3 2H60T X5N7N 1.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9D3a MZWL67T6HBLC-00AD3 VYT6X X5N7N 1.0.1 7.68 TB Capacity
2.2.3.3 - Azure Local Support Matrix for 45n0c (Dell 2509)
Model Supported Operating System
AX-4510c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 0YP04 1.19.1 AX-4510c AX-4520c NA
iDRAC9 with Lifecycle Controller Firmware DUP 6CKFT 7.20.60.50 AX-4510c AX-4520c NA
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-4510c AX-4520c NA
Chassis Manager Firmware DUP WC84H 5 AX-4510c AX-4520c NA
CPLD Firmware DUP G1YRC 1.0.5 AX-4510c AX-4520c NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 HVN2R 23.31.18.10 T5K6M 1.10.3 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4510c AX-4520c
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4520c
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4520c
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-4520c Azure Stack HCI-23H2 Azure Stack HCI-24H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-4520c Azure Stack HCI-23H2 Azure Stack HCI-24H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 M88HH PX286 2.1.13.2034 Inbox AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG1T9TDZ G18YX N71F4 1.6.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG3T8TDZ 2RN2N N71F4 1.6.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE8030 HFS800GDC8X088N 31XDY R2TTT 1.3.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Micron 7450 MTFDKBA800TFS F9MKX JHKXR 1.4.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE9030 HFS800GDJ8X167N FYWN9 9GH86 1.2.1 800GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG 8X8YR 1.2.1 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X 88JVY 1.0.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBA960TFR PH7J6 JHKXR 1.4.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG1T9TFR J927V JHKXR 1.4.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS1T9GDE0X088N MY5M4 19H08 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG3T8TFR 5FP33 JHKXR 1.4.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS3T8GDE0X088N 5JR5H 19H08 1.1.0 3.84TB Capacity
2.2.3.4 - Azure Local Golden Images (Dell 2509)
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Stack HCI OS :
OS build 26100.xxxx (24H2)
OS build 25398.xxxx (23H2)
Azure Local Golden Images for Solution versions 12.2510.1002.* - 12.2603.1002.* with Dell SBE 4.2.2509.*
Azure Local Golden Images for Solution versions 12.2504.1001.* - 12.2509.1001.* with Dell SBE 4.2.2509.*
Azure Local Golden Images for Solution versions 11.2510.1002.* - 11.2603.1002.* with Dell SBE 4.2.2509.*
Azure Local Golden Images for Solution versions 11.2504.1001.* - 11.2509.1001.* with Dell SBE 4.2.2509.*
2.2.4 - Azure Local Support Matrix (Dell 2506)
2.2.4.1 - Azure Local Support Matrix for 14G-15G (Dell 2506)
NOTE
The Dell AX System for Azure Local AX-640, AX-740xd, AX-650, AX-750, AX-7525, and AX-6515 now supports upgrades from Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2. The cluster must have firmware and drivers updated to the levels listed in this support matrix prior to starting the upgrade process.
Please see the following knowledge base article for procedure details and known issues:
Upgrade Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2
Model Supported Operating System
AX-4510c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-640 Windows Server 2022 Datacenter Azure Stack HCI-23H2 (Upgrade only) Azure Stack HCI-24H2
AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 (Upgrade only) Azure Stack HCI-24H2
AX-6515 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-650 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP YR56G 1.18.2 AX-4510c AX-4520c NA
BIOS Firmware DUP T4VCN 2.24.0 AX-640 AX-740xd NA
BIOS Firmware DUP H55DC 2.19.0 AX-6515 NA
BIOS Firmware DUP NTCJ8 2.19.0 AX-7525 NA
BIOS Firmware DUP 0HY8N 1.17.2 AX-650 AX-750 NA
iDRAC9 with Lifecycle Controller Firmware DUP RVDDR 7.00.00.181 AX-640 AX-740xd NA
iDRAC9 with Lifecycle Controller Firmware DUP WN31M 7.20.30.50 AX-6515 AX-7525 AX-650 AX-750 AX-4510c AX-4520c NA
Non-expander Storage Backplane Firmware DUP VV85D 4.35 AX-6515 AX-640 AX-740xd NA
Non-expander Storage Backplane Firmware DUP KW60H 7.1 AX-7525 AX-750 NA
Non-expander Storage Backplane Firmware DUP X3JNV 7.1 AX-650 NA
NVMe Switch Storage Backplane Firmware DUP 5XJWN 1.05 AX-750 NA
Expander Storage Backplane Firmware DUP H9PV3 1.2 AX-7525 AX-750 NA
Expander Storage Backplane Firmware DUP 60K1J 2.52 AX-640 AX-740xd NA
Expander Storage Backplane Firmware DUP 2F90T 2.46 AX-6515 NA
Chipset driver for 14G Intel platforms Driver DUP 4DDMJ 10.1.19913.8607 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Chipset driver for 15G AMD platforms Driver DUP DRN52 6.11.12.245 AX-6515 AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Chipset driver for 15G Intel platforms Driver DUP C2MC3 10.1.19928.8615 AX-650 AX-750 AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-640 AX-740xd AX-6515 AX-7525 AX-650 AX-750 AX-4510c AX-4520c NA
Chassis Manager Firmware DUP WC84H 5 AX-4510c AX-4520c NA
CPLD Firmware DUP 9N4DH 1.0.6 AX-640 NA
CPLD Firmware DUP G65GH 1.1.4 AX-740xd NA
CPLD Firmware DUP 79XGF 1.0.7 AX-6515 NA
CPLD Firmware DUP 4NMC7 1.2.0 AX-7525 NA
CPLD Firmware DUP FCTDF 1.1.1 AX-650 AX-750 NA
CPLD Firmware DUP G1YRC 1.0.5 AX-4510c AX-4520c NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1GbE On-Board LOM JDN4V Management NA 4HVHG 23.22.4 2492H 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-650
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A 4HVHG 23.22.4 2492H 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515
Broadcom 5720 Dual Port 1GbE On-Board LOM 6V45N Management NA 4HVHG 23.22.4 2492H 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-750
Broadcom 5720 Dual Port 1GbE On-Board LOM 74H08 Management NA 4HVHG 23.22.4 2492H 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14 Management Compute (Premium) Storage (Premium) RoCEv2 DRJDR 23.21.14.14 J3MP2 232.1.141.4 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-4520c
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported DRJDR 23.21.14.14 J3MP2 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported DRJDR 23.21.14.14 J3MP2 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported DRJDR 23.21.14.14 J3MP2 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-640 AX-740xd
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A DC20J 24.0.5 PH5GK 24.0.6 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 J4YG9 24 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 J4YG9 24 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 J4YG9 24 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750 AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH 71C1T Management Compute (Premium) Storage (Premium) RoCEv2 1GF8G 16.35.40.30 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP 9FTMY
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 F7V1F
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 JGWVY
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH TDNNT
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP V5DG9
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP 20NJD Management Compute (Premium) Storage (Premium) RoCEv2 76DNG 14.32.21.02 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC R887V Management Compute (Premium) Storage (Premium) RoCEv2 76DNG 14.32.21.02 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 R640 Storage Spaces Direct RN
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH MRT0D Management Compute (Premium) Storage (Premium) RoCEv2 76DNG 14.32.21.02 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-740xd
Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 YGRX3
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM Management Compute (Premium) Storage (Premium) RoCEv2 975XG 22.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 975XG 22.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-7525 AX-650 AX-750 AX-4520c
NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 DN78C Management Compute (Premium) Storage (Premium) RoCEv2 K65HP 26.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-650 AX-750 AX-7525
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 K65HP 26.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 K65HP 26.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-650 AX-750 AX-4520c
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC 165T0 Management N/A 9KYR0 16.20.00 VYWY1 36.20.02 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic 57800 2x10Gb BT + 2x1Gb BT NDC G8RPD
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T and Dual Port 1GbE BASE-T, rNDC 0D1WT Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-640 AX-740xd
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC X1TD1 Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC XVVY1
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP 415DX Management Compute (Premium) Storage (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-6515 AX-7525 AX-640 AX-740xd
QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC 4KF8J
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH 51GRM
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A10 NVIDIA NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 6KNWW 94.02.5C.00.04 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU 8F04V 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-750 AX-7525 AX-4520c Azure Stack HCI-23H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU W3C1G 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-23H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 RV08M 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-23H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-750 AX-7525 AX-4520c Azure Stack HCI-23H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-750 AX-7525 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU HCKJM 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU 7PH29 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-23H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 M88HH VXX8P 2.1.13.2033 Inbox AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
BOSS-S1 2MFVD 3P39V 2.5.13.3024 7004G 1.2.0.1055 AX-6515 AX-7525 AX-640 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
BOSS-S2 FGNRW TTR5R 2.5.13.4009 7004G 1.2.0.1055 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 Inbox 2.51.27.80 AX-640 AX-740XD AX-6515 Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 Inbox 2.51.27.80 AX-740xd Windows Server 2022 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 R31NP 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-23H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-7525 AX-650 AX-750 Windows Server 2025 Datacenter Azure Stack HCI-24H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA M.2 NA Intel S3520 SSDSC2BB120G7R 394XT CHJGV DL43 120 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV240TCB TC2RP H6NHD E013 240 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV480TCB GPGC0 H6NHD E013 480 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV240TDU T2GFX KT63Y J008 240 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV480TDS 7RKD7 KT63Y J008 480 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville RR S4520 SSDSCKKB240GZR CM88M VJPKG DL7C 240 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville S4510 SSDSCKKB240G8R DMC15 Y1P10 DL6R 240 GB Boot
SSD SATA M.2 Read Intensive Micron 5400 MTFDDAV240TGC-1BC1ZABDA T4MJ3 RJ0WY K003 240 GB Boot
SAS 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 2.5 NA Seagate Avenger ST2000NX0463 TMVN7 GW3V7 NT32 2 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt DL2400MM0159 RWR8F DRHV4 ST5J 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ST2400MM0159 36YG1 7N5DH ST7G 2.4 TB Capacity
HDD SAS 2.5 NA Toshiba AL15SE AL15SEB24EQY F9NWJ J11N2 EF09 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ServoBP BL2400MM0159 1D0F5 00P56 SBSA 2.4TB Capacity
SATA 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 2.5 NA Seagate Avenger ST2000NX0423 VR92X GMW4P NB33 2 TB Capacity
SATA 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 3.5 NA HGST Aries K Plus HUS726020ALA610 8NP2N X59KC KV45 2 TB Capacity
HDD SATA 3.5 NA HGST Aries K Plus HUS726040ALA610 61FFW X59KC KV45 4 TB Capacity
HDD SATA 3.5 NA HGST Rainier MLK HUS722T2TALA600 V9H6C V3DJM MU03 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA200NY NPVM6 6D4CG FK5D 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA400NY 95M6K 6D4CG FK5D 4 TB Capacity
HDD SATA 3.5 NA Seagate Nemo ST2000NM0018-2F3130 W8FW5 CMK5N EA04 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST2000NM0145-2DC104 WG9R0 M5GJ1 DB34 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST4000NM0265-2DC107 MWHY9 M5GJ1 DB34 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-A HUS726T4TALA6L0 YH3T9 HV5HH PV09 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-AP HUS728T8TALE6L0 1WMVC T0RX4 RT09 8 TB Capacity
HDD SATA 3.5 NA HGST Libra HE10 HUH721008ALE600 KRV2W H12N2 LT21 8 TB Capacity
HDD SATA 3.5 NA Seagate Makara Plus ST8000NM0205-2FF112 92MDW MR6RH PB53 8 TB Capacity
HDD SATA 3.5 NA Toshiba MG06 MG06ACA800EY 9X09C PT7D8 GA09 8 TB Capacity
HDD SATA 3.5 NA HGST Leo-A He12 HUH721212ALE600 T2YHT JCYF6 NT11 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG07 MG07ACA12TEY 753F0 0942Y GB03 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AC MG08ACA16TEY HPGJ4 WTNDC GC04 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA400NY W2M9N F73C5 GD05 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST4000NM016A-2HZ130 XPJ47 RWK48 CAJD 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST8000NM012A-2KE131 F4JXT TF6TF CALF 8 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST12000NM002J-2TY133 KTJTY 4MPD6 PALB 12 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST16000NM002J-2TW133 JWV1P 4MPD6 PALB 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA800EY T5XR5 GP6NC GE01 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST4000NM018B-2TF130 6KR2M T04YV LC0A 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Aries K Plus HUS726020ALS210 VH6FW 68X4C KU45 2 TB Capacity
HDD SAS 3.5 NA HGST Aries K Plus HUS726040ALS210 X4FKY 68X4C KU45 4 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA20ENY HHX14 RG9MK EG03 2 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA40ENY 1MVTT RG9MK EG03 4 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST2000NM0155 7RCGV XKD4M DT34 2 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST4000NM0295 5JH5X XKD4M DT34 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA HGST Libra HE10 HUH721008AL5200 KRDKK MGW91 LS21 8 TB Capacity
HDD SAS 3.5 NA Seagate Makara Plus ST8000NM0185 M40TH 6421F PT55 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA Seagate Mobula BP ST12000NM0158 YMN53 VTX9C RSL5 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY DK7C9 NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY KFJ7G NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 8MG73 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 4N7V0 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 24HF9 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Seagate Evans ST16000NM010G CNXPV CDP2W ELS8 16 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST4000NM017A KRM6X J12RT CSJA 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST8000NM014A 0N660 0HG6Y CSLE 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Seagate EvansBP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Seagate LongsPeak ST20000NM004D R3G03 56HWT GS07 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
SATA 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF8800CCSE VCRY6 H3XHN DACB 800 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF81D60CSE DMF5Y H3XHN DACB 1.6 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK960TDT XMWMK KT63Y J008 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK3T8TGB-1BC1ZABDA 34JK8 JTW3W K403 3.84 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM960HMJP0D3 DD4G0 97D8J GD57 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM1T9HMJP0D3 K5P0T 97D8J GD57 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH960HAJR0D3 YDHYX 3J3JR HF58 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH1T9HAJR0D3 71K37 3J3JR HF58 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG960G7R TR3MY V141M DL5C 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG019T7R MWKF2 V141M DL5C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG960G8R X31G3 4DW70 DL6B 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R F8N2K 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R 55J8H 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK960TDN HY1F8 W2X8N F005 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK1T9TDN XKF5Y W2X8N F005 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE960G XW4D1 W0YR1 DBC4 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE1T92 0DXJ7 W0YR1 DBC4 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS960G3E2X149N G162V 4T2FN DG00 960GB Cache,Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG960GZR 8MHYH VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG960GZR DYMD0 VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L3960HBLTAD3 96KT6 Y4WVW HH62 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92 TB Cache,Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB960GZR F6H8H VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB960GZR 5M8Y4 VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5200 MTFDDAK1T9TDD VJ36D W2X8N F005 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 SED MTFDDAK3T8TGA-1BC16ABDA 2DXDK JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE1T92 919J7 W0YR1 DBC4 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE3T84 8PYG5 W0YR1 DBC4 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 107CV HG60 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH1T9HMLT0D3 Y24T6 93P7P HE59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS1T9G3H2X069N 962FP N01GW DZ02 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS1T9G32FEH-7A10A 0XMV9 3DTV4 DE08 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB019T8R 33R2T 4DW70 DL6B 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB019T7R XCN15 V141M DL5C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB038T7R 3RRN8 V141M DL5C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB038T8R 1RHK2 4DW70 DL6B 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH3T8HMLT0D3 FYP5F 93P7P HE59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 107CV HG60 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS3T8G32FEH-7410A D6C0R 3DTV4 DE08 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS3T8G3H2X069N 3GDK0 N01GW DZ02 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA10A 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92 TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG800G H6GCD NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG1T60 5GDXH NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G JTKH5 NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 GD3N0 NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG3T20 NKM7P NGPR2 BA48 3.2 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG6T40 6NW3J NGPR2 BA48 6.4 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB080Y CN3JH 1DJXX AS10 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB096Y 503M7 1DJXX AS10 960 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB160Y GVTYD 1DJXX AS10 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB192Y V0K7V 1DJXX AS10 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB384Y 3DDFT 1DJXX AS10 3.84 TB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG800G DHRVV CPP97 B02A 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG1T60 W9G88 CPP97 B02A 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT800HBHQ0D3 GW8T1 VJY6V DWA4 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT1T6HBJR0D3 3TCV6 VJY6V DWA4 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645 MZILT1T6HAJQ0D3 DR0HX 4PPHJ DWF8 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6480BSS200 6VJC9 8W5WF G138 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6416BSS200 6NF96 8W5WF G138 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG960G WFGTH CPP97 B02A 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG1T92 2WVYG CPP97 B02A 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG3T84 91W3V CPP97 B02A 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG960G WMWKG 6DH0W BD48 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG1T92 DHWH5 6DH0W BD48 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG3T84 81H9C 6DH0W BD48 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG800G 81G77 57MM2 C40E 800GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG1T60 G4NY4 57MM2 C40E 1.6TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T20 RGP9J 57MM2 C40E 3.2TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T84 FMP6K 57MM2 C40E 3.84TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG960G J92FY 6DH0W BD48 960 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG1T92 1081V 6DH0W BD48 1.92 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG3T84 MD4YN 6DH0W BD48 3.84 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 CHJJJ NGPR2 BA48 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Plus WUSTR6416ASS200 8W6HC 7HYHH K968 1.6 TB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1519ASS200 5ND33 7HYHH K968 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1538ASS200 YW17N 7HYHH K968 3.84 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA119BSS200 02X38 8W5WF G138 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA138BSS200 FP1KF 8W5WF G138 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT1T9HAJQ0D3 F0VFY J3RRK DSF8 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT3T8HALS0D3 X8F87 J3RRK DSF8 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT7T6HMLA0D3 RVYD5 J3RRK DSF8 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT1T9HBJR0D3 TMTW9 D7RNT DSA4 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT3T8HBLS0D3 CRNPH D7RNT DSA4 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS1T9HEJH0D3 086DD XNGNT DSLA 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS3T8HMLH0D3 JR1HP XNGNT DSLA 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT960HBHQ0D3 K74WN D7RNT DSA4 960 GB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT7T6HALA0D3 84C40 D7RNT DSA4 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 4CN85 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 H9TT5 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 PD02Y NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG1T92 7F2D1 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG3T84 FH1W9 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG1T92 H1P07 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG3T84 3VHY3 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG7T68 5T78C 6DH0W BD48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 VRTN9 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 2XVX2 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 YM0T1 NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG1T92 VGMCD 57MM2 C40E 1.92TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG3T84 YTVTF 57MM2 C40E 3.84TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG7T68 HCTYM 57MM2 C40E 7.68TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG1T92 TDNP7 CPP97 B02A 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG3T84 N85XX CPP97 B02A 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M4 PX05SRB384Y XCRDV 1DJXX AS10 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS3840SE70114 KXDCD NKGWD 3D03 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS1920SE70114 D4VFW NKGWD 3D03 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
Value SAS 2.5" SSD
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS1920SE70134 K9T53 G04C8 4S0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS3840SE70134 4KPKF G04C8 4S0C 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS7680SE70134 2THYF G04C8 4S0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Kioxia Phoenix RM5 KRM5XVUG3T84 X78JM NDG7N B710 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP ISE XS3840LE70154 NWGX3 NX13G 4D0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS960LE70095 2M1NG RRWVT CPE9 960GB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS1920LE70095 K805Y RRWVT CPE9 1.92TB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS3840LE70095 FT95M RRWVT CPE9 3.84TB Cache,Capacity
SSD VSAS 2.5 Read Intensive Kioxia Phoenix RM5 KRM5XRUG7T68 5XD2F NDG7N B710 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate Lange ISE XS7680SE70074 2PKRH H3VHX EC16 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP ISE XS7680SE70154 5KW0F NX13G 4D0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS960LE70134 2RDWT G04C8 4S0C 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS1920LE70134 N6DRV G04C8 4S0C 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS3840LE70134 YM9HP G04C8 4S0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG960G 42XXC 5WMK8 BJ07 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG1T92 N15JP 5WMK8 BJ07 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG3T84 FXYGR 5WMK8 BJ07 3.84 TB Cache, Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG1T92 1FGWG 5WMK8 BJ07 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG3T84 XNXD2 5WMK8 BJ07 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG7T68 5MHY8 5WMK8 BJ07 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG960G 05MT7 1YD58 CA0C 960 GB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG1T92 59XF2 1YD58 CA0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG3T84 M0JVN 1YD58 CA0C 3.84 TB Capacity
SSD vSAS 2.5 Read Intensive Kioxia RM7 KRM7VRUG7T68 D480G 1YD58 CA0C 7.68 TB Capacity
SSD vSAS 2.5 Read Intensive Seagate Cooper XS7680SE70145 1J46N RRWVT CPE9 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Write Intensive Intel Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF SSDPE21K375GAT 3DM57 HMRK7 E201DP38 375 GB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HEHP-000D3 JD6CH 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HMJP-000D3 JDMHM 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung
PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLS-000D3 Y3XT2 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HAJQ-000D3 4WDXY NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HAJQ-000D3 K60N7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLA-000D3 08NMX NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T7T F5P84 CR0HC QDV1DP17 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T7T MCV6J CR0HC QDV1DP17 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T8T 58V30 GD4X4 VDV1DP25 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T8T 2CN1T GD4X4 VDV1DP25 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF SSDPE2KE064T8T X27HY GD4X4 VDV1DP25 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use KIOXIA DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS KCM6FVUL1T60 G7N00 WJD95 3.1.7 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 1.6TB C9X5T CGXH7 1.2.4 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 3.2TB PRKTM CGXH7 1.2.4 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 8FYM9 1.4.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 8FYM9 1.4.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 8FYM9 1.4.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR1T6HBJRAD3 0MNMV 5V3P7 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 VH1YP 2.0.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 VH1YP 2.0.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 VH1YP 2.0.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG1T9TDZ G18YX N71F4 1.6.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG3T8TDZ 2RN2N N71F4 1.6.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE8030 HFS800GDC8X088N 31XDY R2TTT 1.3.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Micron 7450 MTFDKBA800TFS F9MKX HNW5G 1.1.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE9030 HFS800GDJ8X167N FYWN9 8G62T 1.1.0 800GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG CDKNW 1.1.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X 88JVY 1.0.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBA960TFR PH7J6 HNW5G 1.1.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG1T9TFR J927V HNW5G 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS1T9GDE0X088N MY5M4 19H08 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG3T8TFR 5FP33 HNW5G 1.1.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS3T8GDE0X088N 5JR5H 19H08 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG960G DRC9H T79D5 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG3T84 17C57 T79D5 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P4510 SSDPE2KX040T8T 5GMK0 GD4X4 VDV1DP25 4 TB Capacity
NVMe PCIe 2.5 Read Intensive KIOXIA DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS KCM6FRUL1T92 TXP72 WJD95 3.1.7 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX019T9T WPP9G CGXH7 1.2.4 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX038T9T KRT3G CGXH7 1.2.4 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX076T9T RNN67 CGXH7 1.2.4 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR15THALAAD3 182NW 5V3P7 2.5.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 8FYM9 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 8FYM9 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 8FYM9 1.4.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 VH1YP 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF VH1YP 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 VH1YP 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD VH1YP 2.0.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe Add-in Cards
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC MZPLL1T6HEHP-000D3 06V6M 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC MZPLL3T2HMLS-00003 C2KKH 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC MZPLL6T4HMLS-000D3 604N5 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC MZPLL1T6HAJQ-000D3 FTX2R NC07Y 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC MZPLL3T2HAJQ-00005 73KJ7 NC07Y 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC MZPLL6T4HMLA-000D3 FW2K0 NC07Y 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ1T6HBJRAD3 Y7D7D 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ6T4HALAAD3 91FXC 5CM3G 2.5.0 6.4 TB Cache, Capacity
2.2.4.2 - Azure Local Support Matrix for 16G (Dell 2506)
Model Supported Operating System
AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
AX-660 Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP XK9CT 2.6.3 AX-660 AX-760 NA
Chipset driver for 16G Intel platforms Driver DUP R40PW 10.1.19928.8615 AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
iDRAC9 with Lifecycle Controller Firmware DUP WN31M 7.20.30.50 AX-660 AX-760 NA
Expander Storage Backplane Firmware DUP J9JW2 1.61 AX-760 NA
NVMe Switch Storage Backplane Firmware DUP WR74F 3.32 AX-760 NA
Non-expander Storage Backplane Firmware DUP GXH37 7.1 AX-760 NA
Non-expander Storage Backplane Firmware DUP 6Y9X7 7.1 AX-660 NA
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-660 AX-760 NA
CPLD Firmware DUP 503F0 1.2.6 AX-660 AX-760 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card 5NN70 Management N/A 4HVHG 23.22.4 2492H 232.1.141.4 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Broadcom 57504 Quad Port 10/25GbE, SFP28 Adapter 3Y64D Management Compute (Premium) Storage (Premium) RoCEv2 DRJDR 23.21.14.14 J3MP2 232.1.141.4 Windows Server 2025 Datacenter Azure Stack HCI-24H2 AX-660 AX-760
Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH J3D14
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 N11TD 24.0.5 J4YG9 24 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 975XG 22.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 K65HP 26.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-660 AX-760
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter DN78C
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 K65HP 26.44.10.36 3G71F 25.1 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2 AX-760
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 553.62 Yes AX-760 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-23H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-760 Azure Stack HCI-23H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 95.02.66.00.02 553.62 Yes AX-760 Azure Stack HCI-23H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 WW56V 33TD2 2.1.13.2033 Inbox Inbox AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2 Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 HDH8G 2.61.74.00 AX-660 AX-760 Windows Server 2025 Datacenter Azure Stack HCI-24H2
HBA355i K6MCJ CG0P9 33.15.00.00 M2P63 2.61.48.00 AX-660 AX-760 Windows Server 2022 Datacenter Azure Stack HCI-23H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBA960TDZ PRV6C N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG960TDZ 0V8F7 N71F4 1.6.0 960GB Boot
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SDA400NY 9VN79 99TKP EP02 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T XF65R PSLG 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR XF65R PSLG 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 Read Intensive Seagate LongsPeak ST20000NM004D R3G03 56HWT GS07 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA Seagate CimarronBP(EWP) DL4000NM019B F7DTR M7PKX LBW4 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST12000NM007H FN7VR 3VY0D SWS9 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA16TEY MXC46 8829H EM05 16 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST16000NM007H R0G8W C50CR SYS9 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SCA20TEY NT45N 0H3CX EN04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-D PR2 WUH722020BL5200 1D4CR YH8C3 VS18 20 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST20000NM007H R5KP7 C50CR SYS9 20 TB Capacity
HDD SAS 3.5 NA WD London DP WUH722420AL5200 MTTCF FN2N1 YS01 20 TB Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 107CV HG60 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L31T9HELAAD3 PTD53 NF72T HL56 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK1T9TGA-1BC1ZABDA KXNX5 RJ0WY K003 1.92TB Capacity
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 107CV HG60 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L33T8HELAAD3 D7V89 NF72T HL56 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84TB Capacity
SSD SATA 2.5 Mixed Use Intel S4620 SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897a MZ7L31T9HENAAD3 GR4WN KHC8M HK56 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK1T9TGB-1BC1ZABDA XRXX2 RJ0WY K003 1.92TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJRAD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLSAD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALAAD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 VH1YP 2.0.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 VH1YP 2.0.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 VH1YP 2.0.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLSAD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALAAD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 VH1YP 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF VH1YP 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 VH1YP 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD VH1YP 2.0.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG7T68 0RD61 K6597 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS960GECTX088N WR2FG T1XKD 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS7T6GEETX099N RG3T2 TDGKY 1.1.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG960G YNGYD HV8P1 2.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC960TFR KXT48 RPTG2 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC960TGP G7NCH HW0R3 1.1.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL2960HCJRAD3 6HYWM XMFKX 1.1.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJRAD3 8PMRM 28J8R 1.1.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR1T9HBJRAD3 WPR17 5V3P7 2.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL21T9H TGYF5 XMFKX 1.1.1 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC1T9TFR JH61J RPTG2 1.3.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC1T9TGP M7RHM HW0R3 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS1T9GEETX099N 147DR TDGKY 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC3T8TFR NDK2D RPTG2 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG3T84 RFYP9 K6597 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS3T8GECTX088N V6WP5 T1XKD 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL23T8HCLSAD3 P7G03 XMFKX 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC3T8TGP GT3F3 HW0R3 1.1.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL27T6HBLAAD3 30FX3 XMFKX 1.1.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC7T6TFR 91KYJ RPTG2 1.3.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC7T6TGP RTJFW HW0R3 1.1.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS960GEETX099N 26WJ0 TDGKY 1.1.0 960GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO1T9HCJR-00AD3 G64N5 V7V0K 1.0.0 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS3T8GEETX099N 2V97V TDGKY 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO15THBLA-00AD3 VPWMR V7V0K 1.0.0 15.36TB Capacity
2.2.4.3 - Azure Local Golden Images (Dell 2506)
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Local Golden Images for Solution version 11.*.1001.*
Azure Local Golden Images for Solution version 12.*.1001.*
* New golden image with support for imaging servers with and without OEM licensing.
2.2.5 - Azure Local Support Matrix (Dell 2503)
2.2.5.1 - Azure Local Support Matrix for 14G-15G (Dell 2503)
NOTE
The Dell AX System for Azure Local AX-640, AX-740xd, AX-650, AX-750, AX-7525, and AX-6515 now supports upgrades from Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2. The cluster must have firmware and drivers updated to the levels listed in this support matrix prior to starting the upgrade process.
Please see the following knowledge base article for procedure details and known issues:
Upgrade Azure Stack HCI operating system 22H2 to Azure Stack HCI operating system 23H2
Model Supported Operating System
AX-4510c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
AX-640 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 (Upgrade from Azure Stack HCI-22H2 only)
AX-740xd Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 (Upgrade from Azure Stack HCI-22H2 only)
AX-6515 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 (Upgrade from Azure Stack HCI-22H2 only)
AX-7525 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
AX-650 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
R640 Storage Spaces Direct RN Windows Server 2019 Datacenter
R740xd Storage Spaces Direct RN Windows Server 2019 Datacenter
R440 Storage Spaces Direct RN Windows Server 2019 Datacenter
R740xd2 Storage Spaces Direct RN Windows Server 2019 Datacenter
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP 34WHP 1.17.3 AX-4510c AX-4520c NA
BIOS Firmware DUP J6D53 2.23.0 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN NA
BIOS Firmware DUP NF1D9 2.24.0 R440 Storage Spaces Direct RN NA
BIOS Firmware DUP 0DCDT 2.23.0 R740xd2 Storage Spaces Direct RN NA
BIOS Firmware DUP XRCDW 2.18.1 AX-6515 NA
BIOS Firmware DUP 3R62V 2.18.1 AX-7525 NA
BIOS Firmware DUP K3R8K 1.16.2 AX-650 AX-750 NA
iDRAC9 with Lifecycle Controller Firmware DUP RVDDR 7.00.00.181 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740x2 Storage Spaces Direct RN NA
iDRAC9 with Lifecycle Controller Firmware DUP 5MXXN 7.20.10.50 AX-6515 AX-7525 AX-650 AX-750 AX-4510c AX-4520c NA
Non-expander Storage Backplane Firmware DUP VV85D 4.35 AX-6515 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN NA
Non-expander Storage Backplane Firmware DUP KW60H 7.1 AX-7525 AX-750 NA
Non-expander Storage Backplane Firmware DUP X3JNV 7.1 AX-650 NA
NVMe Switch Storage Backplane Firmware DUP 5XJWN 1.05 AX-750 NA
Expander Storage Backplane Firmware DUP H9PV3 1.2 AX-7525 AX-750 NA
Expander Storage Backplane Firmware DUP 60K1J 2.52 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740x2 Storage Spaces Direct RN NA
Expander Storage Backplane Firmware DUP 2F90T 2.46 AX-6515 NA
Chipset driver for 14G Intel platforms Driver DUP 4DDMJ 10.1.19913.8607 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740x2 Storage Spaces Direct RN Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
Chipset driver for 15G AMD platforms Driver DUP C81D9 6.06.30.2344 AX-6515 AX-7525 Windows Server 2022 Datacenter Windows Server 2025 Datacenter
Chipset driver for 15G AMD platforms Driver DUP 4GJTG 6.02.22.100 AX-6515 AX-7525 Windows Server 2019 Datacenter Azure Stack HCI-23H2
Chipset driver for 15G AMD platforms Driver DUP NJ9WJ 2.18.30.202 AX-6515 AX-7525 Azure Stack HCI-22H2
Chipset driver for 15G Intel platforms ICX-D Driver DUP MKTXT 10.1.19928.8615 AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
Chipset driver for 15G Intel platforms Driver DUP H0WTV 10.1.19913.8607 AX-650 AX-750 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740x2 Storage Spaces Direct RN AX-6515 AX-7525 AX-650 AX-750 NA
Chassis Manager Firmware DUP WC84H 5 AX-4510c AX-4520c
CPLD Firmware DUP 9N4DH 1.0.6 AX-640 NA
CPLD Firmware DUP G65GH 1.1.4 AX-740xd NA
CPLD Firmware DUP 79XGF 1.0.7 AX-6515 NA
CPLD Firmware DUP 4NMC7 1.2.0 AX-7525 NA
CPLD Firmware DUP FCTDF 1.1.1 AX-650 AX-750 NA
CPLD Firmware DUP G1YRC 1.0.5 AX-4510c AX-4520c NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A RXW7G 22.91.5 GJ9N4 230.1.116.0 Windows Server 2019 Datacenter AX-6515
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported CN7W6 23.21.13.34 G535X 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-640 AX-740xd
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP Management Compute (Standard) Not Supported CN7W6 23.21.13.34 G535X 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4 Management Compute (Standard) Not Supported CN7W6 23.21.13.34 G535X 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported FXD3N 23.21.13.39 G535X 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported FXD3N 23.21.13.39 G535X 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card KJMHJ Management N/A J8X0M 23.21.6 YWMRX 232.1.133.2 Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC NWMNX Management Compute (Standard) Not Supported VFGJN 22.92.06.10 FPMGT 230.1.116.0 Windows Server 2019 Datacenter AX-640 AX-740xd
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 24FG6 Management Compute (Standard) Not Supported VFGJN 22.92.06.10 FPMGT 230.1.116.0 Windows Server 2019 Datacenter AX-6515
Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card 6XH9X
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card 930PP
Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card J4RN3
Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz NHN45
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card WC9TR
Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 CP610 Management Compute (Standard) Not Supported VFGJN 22.92.06.10 FPMGT 230.1.116.0 Windows Server 2019 Datacenter AX-7525 AX-650 AX-750
Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 KHCTP
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 T6HR8
Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 X1KR4
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A 234W1 23.0.8 6JHVK 23.0.0 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A 234W1 23.0.8 6JHVK 23.0.0 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT Management Compute (Standard) N/A 234W1 23.0.8 6JHVK 23.0.0 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750
Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC 6VDPG Management Compute (Standard) N/A 234W1 23.0.8 R71XY 23.0.0 Windows Server 2025 Datacenter AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN
Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 50RV4 Management Compute (Standard) N/A 234W1 23.0.8 R71XY 23.0.0 Windows Server 2025 Datacenter AX-7525 AX-650 AX-750
Intel(R) Ethernet 10G 4P X710-T4L-t Adapter ND4PT
Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 VF81P
Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 VMFKR
Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 YJYK1
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 6JHVK 23.0.0 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 6JHVK 23.0.0 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 6JHVK 23.0.0 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750 AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E823 KJMHJ Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 R71XY 23.0.0 Windows Server 2025 Datacenter AX-4510c AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 R71XY 23.0.0 Windows Server 2025 Datacenter AX-7525 AX-650 AX-750
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 R71XY 23.0.0 Windows Server 2025 Datacenter AX-7525 AX-650 AX-750 AX-4520c
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-650 AX-750
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-7525 AX-650 AX-750 AX-4520c
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP 20NJD Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC R887V Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-640 R640 Storage Spaces Direct RN
Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH MRT0D Management Compute (Premium) Storage (Premium) RoCEv2 XGP2X 14.32.20.04 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-740xd R740xd Storage Spaces Direct RN R740xd Storage Spaces Direct RN
Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 YGRX3
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH 71C1T Management Compute (Premium) Storage (Premium) RoCEv2 XY16R 16.35.30.06 G6M58 24.04.03 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN AX-650 AX-750
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP 9FTMY
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 F7V1F
Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 JGWVY
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH TDNNT
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP V5DG9
NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 DN78C Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-650 AX-750 AX-7525
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-650 AX-750 AX-4520c
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.04.03 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-650 AX-750
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC 165T0 Management N/A 9KYR0 16.20.00 VYWY1 36.20.02 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN
QLogic 57800 2x10Gb BT + 2x1Gb BT NDC G8RPD
QLogic FastLinQ 41264 Dual Port 10GbE SFP+, Dual Port 1GbE, rNDC 5V6Y4 Management Not Supported W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2019 Datacenter R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T & Dual Port 1GbE BASE-T, rNDC 0D1WT Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC X1TD1 Management Compute (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN AX-650 AX-750
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC XVVY1
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP 415DX Management Compute (Premium) Storage (Premium) iWARP W93NY 16.30.09 RXJPP 36.30.16 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-6515 AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN
QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC 4KF8J
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH 51GRM
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A10 NVIDIA NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 6KNWW 94.02.5C.00.04 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU 8F04V 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 528.89 WHQL Yes AX-750 AX-7525 AX-4520c Azure Stack HCI-22H2 Azure Stack HCI-23H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU W3C1G 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A30 NVIDIA NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 RV08M 92.00.58.00.01 528.89 WHQL No AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A40 NVIDIA NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU W6GX6 94.02.5C.00.0F 528.89 WHQL Yes AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 528.89 WHQL Yes AX-650 AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 528.89 WHQL Yes AX-750 AX-7525 AX-4520c Azure Stack HCI-22H2 Azure Stack HCI-23H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-750 AX-7525 Azure Stack HCI-22H2 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU HCKJM 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-22H2 Azure Stack HCI-23H2
T4 NVIDIA NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU 7PH29 90.04.96.00.01 528.89 WHQL No AX-750 Azure Stack HCI-22H2 Azure Stack HCI-23H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 M88HH VXX8P 2.1.13.2033 Inbox AX-4510c AX-4520c Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-23H2
BOSS-S1 2MFVD 3P39V 2.5.13.3024 8KKVC 1.2.0.1052 AX-6515 AX-7525 AX-640 AX-740xd R640 Storage Spaces Direct RN R740xd Storage Spaces Direct RN R440 Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
BOSS-S2 FGNRW TTR5R 2.5.13.4009 8KKVC 1.2.0.1052 AX-7525 AX-650 AX-750 Windows Server 2019 Datacenter Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 MF8G0 2.51.25.02 R440 Storage Spaces Direct RN AX-640 R640 Storage Spaces Direct RN AX-740XD R740xd Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN AX-6515 Windows Server 2019 Datacenter
HBA330 Controller, 12Gps Mini Card P2R3R 124X2 16.17.01.00 Inbox 2.51.27.80 R440 Storage Spaces Direct RN AX-640 R640 Storage Spaces Direct RN AX-740XD R740xd Storage Spaces Direct RN R740xd2 Storage Spaces Direct RN AX-6515 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 MF8G0 2.51.25.02 AX-740xd R740xd Storage Spaces Direct RN Windows Server 2019 Datacenter
HBA330 Controller, 12Gps Mini Card, LP J7TNV NKNVC 16.17.01.00 Inbox 2.51.27.80 AX-740xd R740xd Storage Spaces Direct RN Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
HBA355i K6MCJ Y99R5 24.15.14.00 WFV95 2.61.48.00 AX-7525 AX-650 AX-750 Windows Server 2019 Datacenter
HBA355i K6MCJ Y99R5 24.15.14.00 M2P63 2.61.48.00 AX-7525 AX-650 AX-750 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
HBA355i K6MCJ Y99R5 24.15.14.00 4MJP3 2.61.69.00 AX-7525 AX-650 AX-750 Windows Server 2025 Datacenter
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA M.2 NA Intel S3520 SSDSC2BB120G7R 394XT CHJGV DL43 120 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV240TCB TC2RP H6NHD E013 240 GB Boot
SSD SATA M.2 NA Micron 5100 MTFDDAV480TCB GPGC0 H6NHD E013 480 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV240TDU T2GFX KT63Y J008 240 GB Boot
SSD SATA M.2 NA Micron 5300 MTFDDAV480TDS 7RKD7 KT63Y J008 480 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville RR S4520 SSDSCKKB240GZR CM88M VJPKG DL7C 240 GB Boot
SSD SATA M.2 Read Intensive Intel Youngsville S4510 SSDSCKKB240G8R DMC15 Y1P10 DL6R 240 GB Boot
SSD SATA M.2 Read Intensive Micron 5400 MTFDDAV240TGC-1BC1ZABDA T4MJ3 RJ0WY K003 240 GB Boot
SAS 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 2.5 NA Seagate Avenger ST2000NX0463 TMVN7 GW3V7 NT32 2 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt DL2400MM0159 RWR8F 61VGT ST5E 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ST2400MM0159 36YG1 D64H2 ST7C 2.4 TB Capacity
HDD SAS 2.5 NA Toshiba AL15SE AL15SEB24EQY F9NWJ J11N2 EF09 2.4 TB Capacity
HDD SAS 2.5 NA Seagate Skybolt ServoBP BL2400MM0159 1D0F5 CF4VF SBS6 2.4TB Capacity
SATA 2.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 2.5 NA Seagate Avenger ST2000NX0423 VR92X GMW4P NB33 2 TB Capacity
SATA 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SATA 3.5 NA HGST Aries K Plus HUS726020ALA610 8NP2N X59KC KV45 2 TB Capacity
HDD SATA 3.5 NA HGST Aries K Plus HUS726040ALA610 61FFW X59KC KV45 4 TB Capacity
HDD SATA 3.5 NA HGST Rainier MLK HUS722T2TALA600 V9H6C V3DJM MU03 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA200NY NPVM6 6D4CG FK5D 2 TB Capacity
HDD SATA 3.5 NA Toshiba Tomcat R MG04ACA400NY 95M6K 6D4CG FK5D 4 TB Capacity
HDD SATA 3.5 NA Seagate Nemo ST2000NM0018-2F3130 W8FW5 CMK5N EA04 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST2000NM0145-2DC104 WG9R0 M5GJ1 DB34 2 TB Capacity
HDD SATA 3.5 NA Seagate Makara BP ST4000NM0265-2DC107 MWHY9 M5GJ1 DB34 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-A HUS726T4TALA6L0 YH3T9 HV5HH PV09 4 TB Capacity
HDD SATA 3.5 NA HGST Vela-AP HUS728T8TALE6L0 1WMVC T0RX4 RT09 8 TB Capacity
HDD SATA 3.5 NA HGST Libra HE10 HUH721008ALE600 KRV2W H12N2 LT21 8 TB Capacity
HDD SATA 3.5 NA Seagate Makara Plus ST8000NM0205-2FF112 92MDW MR6RH PB53 8 TB Capacity
HDD SATA 3.5 NA Toshiba MG06 MG06ACA800EY 9X09C PT7D8 GA09 8 TB Capacity
HDD SATA 3.5 NA HGST Leo-A He12 HUH721212ALE600 T2YHT JCYF6 NT11 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG07 MG07ACA12TEY 753F0 0942Y GB03 12 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AC MG08ACA16TEY HPGJ4 WTNDC GC04 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA400NY W2M9N F73C5 GD05 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST4000NM016A-2HZ130 XPJ47 RWK48 CAJD 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron ST8000NM012A-2KE131 F4JXT TF6TF CALF 8 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST12000NM002J-2TY133 KTJTY 4MPD6 PALB 12 TB Capacity
HDD SATA 3.5 NA Seagate Evans BP ST16000NM002J-2TW133 JWV1P 4MPD6 PALB 16 TB Capacity
HDD SATA 3.5 NA Toshiba MG08AD MG08ADA800EY T5XR5 GP6NC GE01 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST4000NM018B-2TF130 6KR2M T04YV LC0A 4 TB Capacity
HDD SATA 3.5 NA Seagate Cimarron BP ST8000NM023B-2TJ133 J7W80 P183W LA0C 8 TB Capacity
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Aries K Plus HUS726020ALS210 VH6FW 68X4C KU45 2 TB Capacity
HDD SAS 3.5 NA HGST Aries K Plus HUS726040ALS210 X4FKY 68X4C KU45 4 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA20ENY HHX14 RG9MK EG03 2 TB Capacity
HDD SAS 3.5 NA Toshiba Tomcat R MG04SCA40ENY 1MVTT RG9MK EG03 4 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST2000NM0155 7RCGV XKD4M DT34 2 TB Capacity
HDD SAS 3.5 NA Seagate Makara BP ST4000NM0295 5JH5X XKD4M DT34 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA HGST Libra HE10 HUH721008AL5200 KRDKK MGW91 LS21 8 TB Capacity
HDD SAS 3.5 NA Seagate Makara Plus ST8000NM0185 M40TH 6421F PT55 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA Seagate Mobula BP ST12000NM0158 YMN53 VTX9C RSL5 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY DK7C9 NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG07 MG07SCA12TEY KFJ7G NFFHM EI0D 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 8MG73 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 4N7V0 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SC MG08SCA16TEY 24HF9 9N3RR EJ09 16 TB Capacity
HDD SAS 3.5 NA Seagate Evans ST16000NM010G CNXPV CDP2W ELS8 16 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST4000NM017A KRM6X J12RT CSJA 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron ST8000NM014A 0N660 0HG6Y CSLE 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T 92VPG PSLB 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR 92VPG PSLB 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Seagate EvansBP ST16000NM006J 41DXR 92VPG PSLB 16 TB Capacity
HDD SAS 3.5 NA Seagate LongsPeak ST20000NM004D R3G03 56HWT GS07 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
SATA 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF8800CCSE VCRY6 H3XHN DACB 800 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Toshiba HK4 THNSF81D60CSE DMF5Y H3XHN DACB 1.6 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK960TDT XMWMK KT63Y J008 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK3T8TGB-1BC1ZABDA 34JK8 JTW3W K403 3.84 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM960HMJP0D3 DD4G0 97D8J GD57 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM863a MZ7KM1T9HMJP0D3 K5P0T 97D8J GD57 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH960HAJR0D3 YDHYX 3J3JR HF58 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Samsung SM883 MZ7KH1T9HAJR0D3 71K37 3J3JR HF58 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG960G7R TR3MY V141M DL5C 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4600 SSDSC2KG019T7R MWKF2 V141M DL5C 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG960G8R X31G3 4DW70 DL6B 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R F8N2K 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Intel S4610 SSDSC2KG019T8R 55J8H 4DW70 DL6B 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK960TDN HY1F8 W2X8N F005 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Micron 5200 MTFDDAK1T9TDN XKF5Y W2X8N F005 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE960G XW4D1 W0YR1 DBC4 960 GB Cache, Capacity
SSD SATA 2.5 Mixed Use Kioxia HK6-V KHK6YVSE1T92 0DXJ7 W0YR1 DBC4 1.92 TB Cache, Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS960G3E2X149N G162V 4T2FN DG00 960GB Cache,Capacity
SSD SATA 2.5 Mixed Use Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG960GZR 8MHYH VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville-RR SSDSC2KG019TZR 8RXV5 VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG960GZR DYMD0 VJPKG DL7C 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Intel Youngsville RR (New) (S4620) SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92 TB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L3960HBLTAD3 96KT6 Y4WVW HH62 960 GB Cache,Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92 TB Cache,Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB960GZR F6H8H VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB960GZR 5M8Y4 VJPKG DL7C 960 GB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville RR (New) (S4520) SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5200 MTFDDAK1T9TDD VJ36D W2X8N F005 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 SED MTFDDAK3T8TGA-1BC16ABDA 2DXDK JTW3W K403 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE1T92 919J7 W0YR1 DBC4 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Kioxia HK6-R KHK6YRSE3T84 8PYG5 W0YR1 DBC4 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 J81VT HG59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH1T9HMLT0D3 Y24T6 93P7P HE59 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS1T9G3H2X069N 962FP N01GW DZ02 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS1T9G32FEH-7A10A 0XMV9 3DTV4 DE08 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB019T8R 33R2T 4DW70 DL6B 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB019T7R XCN15 V141M DL5C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4500 SSDSC2KB038T7R 3RRN8 V141M DL5C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel S4510 SSDSC2KB038T8R 1RHK2 4DW70 DL6B 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883 MZ7LH3T8HMLT0D3 FYP5F 93P7P HE59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD J81VT HG59 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE4011 HFS3T8G32FEH-7410A D6C0R 3DTV4 DE08 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Hynix SE5110 HFS3T8G3H2X069N 3GDK0 N01GW DZ02 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB019TZR VYYW8 VJPKG DL7C 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Intel Youngsville-RR SSDSC2KB038TZR WNPN1 VJPKG DL7C 3.84 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92 TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA10A 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS960G32FEH-BA1 7GR2K 2CY65 DD02 960 GB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92 TB Capacity
SSD SATA 2.5 Mixed Use Hynix SE5031 HFS1T9G32FEH-BA1 GKTF1 2CY65 DD02 1.92 TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG800G H6GCD NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia PM6 KPM6XMUG1T60 5GDXH NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G JTKH5 NGPR2 BA48 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 GD3N0 NGPR2 BA48 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG3T20 NKM7P NGPR2 BA48 3.2 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG6T40 6NW3J NGPR2 BA48 6.4 TB Cache,Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB080Y CN3JH 1DJXX AS10 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB096Y 503M7 1DJXX AS10 960 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M4 PX05SMB160Y GVTYD 1DJXX AS10 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB192Y V0K7V 1DJXX AS10 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M4 PX05SVB384Y 3DDFT 1DJXX AS10 3.84 TB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG800G DHRVV CPP97 B02A 800 GB Cache, Capacity
SSD SAS 2.5 Write Intensive Kioxia Phoenix M5-M KPM5XMUG1T60 W9G88 CPP97 B02A 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT800HBHQ0D3 GW8T1 VJY6V DWA4 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645a MZILT1T6HBJR0D3 3TCV6 VJY6V DWA4 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Samsung PM1645 MZILT1T6HAJQ0D3 DR0HX 4PPHJ DWF8 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6480BSS200 6VJC9 8W5WF G138 800 GB Cache, Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Quantum WUSTR6416BSS200 6NF96 8W5WF G138 1.6 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG960G WFGTH CPP97 B02A 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG1T92 2WVYG CPP97 B02A 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia Phoenix M5-V KPM5XVUG3T84 91W3V CPP97 B02A 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG960G WMWKG 6DH0W BD48 960 GB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG1T92 DHWH5 6DH0W BD48 1.92 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 FIPS KPM6WVUG3T84 81H9C 6DH0W BD48 3.84 TB Cache, Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG800G 81G77 57MM2 C40E 800GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG1T60 G4NY4 57MM2 C40E 1.6TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T20 RGP9J 57MM2 C40E 3.2TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 (FIPS) KPM7WVUG3T84 FMP6K 57MM2 C40E 3.84TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG960G J92FY 6DH0W BD48 960 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG1T92 1081V 6DH0W BD48 1.92 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6WVUG3T84 MD4YN 6DH0W BD48 3.84 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG1T60 CHJJJ NGPR2 BA48 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use WD Bear Cove Plus WUSTR6416ASS200 8W6HC 7HYHH K968 1.6 TB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1519ASS200 5ND33 7HYHH K968 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Plus WUSTR1538ASS200 YW17N 7HYHH K968 3.84 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA119BSS200 02X38 8W5WF G138 1.92 TB Capacity
SSD SAS 2.5 Read Intensive WD Bear Cove Quantum WUSTVA138BSS200 FP1KF 8W5WF G138 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT1T9HAJQ0D3 F0VFY J3RRK DSF8 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT3T8HALS0D3 X8F87 J3RRK DSF8 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643 MZILT7T6HMLA0D3 RVYD5 J3RRK DSF8 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT1T9HBJR0D3 TMTW9 D7RNT DSA4 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT3T8HBLS0D3 CRNPH D7RNT DSA4 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS1T9HEJH0D3 086DD XNGNT DSLA 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1633a MZILS3T8HMLH0D3 JR1HP XNGNT DSLA 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT960HBHQ0D3 K74WN D7RNT DSA4 960 GB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1643a MZILT7T6HALA0D3 84C40 D7RNT DSA4 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 4CN85 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 H9TT5 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 PD02Y NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG1T92 7F2D1 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 FIPS KPM6WRUG3T84 FH1W9 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG1T92 H1P07 6DH0W BD48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG3T84 3VHY3 6DH0W BD48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6WRUG7T68 5T78C 6DH0W BD48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG1T92 VRTN9 NGPR2 BA48 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG3T84 2XVX2 NGPR2 BA48 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM6 KPM6XRUG7T68 YM0T1 NGPR2 BA48 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG1T92 VGMCD 57MM2 C40E 1.92TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG3T84 YTVTF 57MM2 C40E 3.84TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 (FIPS) KPM7WRUG7T68 HCTYM 57MM2 C40E 7.68TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG1T92 TDNP7 CPP97 B02A 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M5-R KPM5XRUG3T84 N85XX CPP97 B02A 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia Phoenix M4 PX05SRB384Y XCRDV 1DJXX AS10 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS3840SE70114 KXDCD NKGWD 3D03 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Seagate LangeBP XS1920SE70114 D4VFW NKGWD 3D03 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
Value SAS 2.5" SSD
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS1920SE70134 K9T53 G04C8 4S0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS3840SE70134 4KPKF G04C8 4S0C 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP SED XS7680SE70134 2THYF G04C8 4S0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Kioxia Phoenix RM5 KRM5XVUG3T84 X78JM NDG7N B710 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP ISE XS3840LE70154 NWGX3 NX13G 4D0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS960LE70095 2M1NG RRWVT CPE9 960GB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS1920LE70095 K805Y RRWVT CPE9 1.92TB Cache,Capacity
SSD VSAS 2.5 Mixed Use Seagate Cooper (Nytro 2550) XS3840LE70095 FT95M RRWVT CPE9 3.84TB Cache,Capacity
SSD VSAS 2.5 Read Intensive Kioxia Phoenix RM5 KRM5XRUG7T68 5XD2F NDG7N B710 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate Lange ISE XS7680SE70074 2PKRH H3VHX EC16 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Seagate LangeBP ISE XS7680SE70154 5KW0F NX13G 4D0C 7.68 TB Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS960LE70134 2RDWT G04C8 4S0C 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS1920LE70134 N6DRV G04C8 4S0C 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Seagate LangeBP SED XS3840LE70134 YM9HP G04C8 4S0C 3.84 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG960G 42XXC 5WMK8 BJ07 960 GB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG1T92 N15JP 5WMK8 BJ07 1.92 TB Cache, Capacity
SSD VSAS 2.5 Mixed Use Kioxia RM6 KRM6VVUG3T84 FXYGR 5WMK8 BJ07 3.84 TB Cache, Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG1T92 1FGWG 5WMK8 BJ07 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG3T84 XNXD2 5WMK8 BJ07 3.84 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM6 KRM6VRUG7T68 5MHY8 5WMK8 BJ07 7.68 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG960G 05MT7 1YD58 CA0C 960 GB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG1T92 59XF2 1YD58 CA0C 1.92 TB Capacity
SSD VSAS 2.5 Read Intensive Kioxia RM7 KRM7VVUG3T84 M0JVN 1YD58 CA0C 3.84 TB Capacity
SSD vSAS 2.5 Read Intensive Kioxia RM7 KRM7VRUG7T68 D480G 1YD58 CA0C 7.68 TB Capacity
SSD vSAS 2.5 Read Intensive Seagate Cooper XS7680SE70145 1J46N RRWVT CPE9 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Write Intensive Intel Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF SSDPE21K375GAT 3DM57 HMRK7 E201DP38 375 GB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HEHP-000D3 JD6CH 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HMJP-000D3 JDMHM 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung
PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLS-000D3 Y3XT2 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF MZWLL1T6HAJQ-000D3 4WDXY 3JJHC 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF MZWLL3T2HAJQ-000D3 K60N7 3JJHC 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF MZWLL6T4HMLA-000D3 08NMX 3JJHC 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T7T F5P84 CR0HC QDV1DP17 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T7T MCV6J CR0HC QDV1DP17 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF SSDPE2KE016T8T 58V30 GD4X4 VDV1DP25 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF SSDPE2KE032T8T 2CN1T GD4X4 VDV1DP25 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF SSDPE2KE064T8T X27HY GD4X4 VDV1DP25 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use KIOXIA DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS KCM6FVUL1T60 G7N00 WJD95 3.1.7 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJR-00AD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe NA Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL1T60 P03YC GMM6V 2.2.2 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 1.6TB C9X5T CGXH7 1.2.4 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel P5600 SP 3WPD D7 P5600 Series 3.2TB PRKTM CGXH7 1.2.4 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 8FYM9 1.4.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 8FYM9 1.4.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 8FYM9 1.4.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE016T1E 82TVJ 76F7P 1.2.0 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE032T1E TY3M5 76F7P 1.2.0 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Intel Arbordale Plus RR P5620 SSDPF2KE064T1E 5WCR8 76F7P 1.2.0 6.4TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR1T6HBJR-00AD3 0MNMV 5V3P7 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLS-00AD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALA-00AD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 85C0H 1.1.2 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 85C0H 1.1.2 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 85C0H 1.1.2 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 5JJFF 2.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 5JJFF 2.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 5JJFF 2.0.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG1T9TDZ G18YX N71F4 1.6.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG3T8TDZ 2RN2N N71F4 1.6.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE8030 HFS800GDC8X088N 31XDY R2TTT 1.3.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Micron 7450 MTFDKBA800TFS F9MKX HNW5G 1.1.0 800GB Capacity
NVMe PCIe M.2 Mixed Use Hynix PE9030 HFS800GDJ8X167N FYWN9 8G62T 1.1.0 800GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GDJ8X167N XN5KG CDKNW 1.1.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8010 HFS960GDC8X099N 21GXV R2TTT 1.3.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE9010 HFS960GEJ8X167N 4H05X 88JVY 1.0.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBA960TFR PH7J6 HNW5G 1.1.0 960GB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG1T9TFR J927V HNW5G 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS1T9GDE0X088N MY5M4 19H08 1.1.0 1.92TB Capacity
NVMe PCIe M.2 Read Intensive Micron 7450 MTFDKBG3T8TFR 5FP33 HNW5G 1.1.0 3.84TB Capacity
NVMe PCIe M.2 Read Intensive Hynix PE8110 HFS3T8GDE0X088N 5JR5H 19H08 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG960G DRC9H T79D5 1.2.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Toshiba CD5 KCD5XLUG3T84 17C57 T79D5 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P4510 SSDPE2KX040T8T 5GMK0 GD4X4 VDV1DP25 4 TB Capacity
NVMe PCIe 2.5 Read Intensive KIOXIA DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS KCM6FRUL1T92 TXP72 WJD95 3.1.7 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX019T9T WPP9G CGXH7 1.2.4 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX038T9T KRT3G CGXH7 1.2.4 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel P5500 SSDPF2KX076T9T RNN67 CGXH7 1.2.4 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLS-00AD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALA-00AD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR15THALA-00AD3 182NW 5V3P7 2.5.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 85C0H 1.1.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 85C0H 1.1.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 85C0H 1.1.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 8FYM9 1.4.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 8FYM9 1.4.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 8FYM9 1.4.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX019T1E 0HVC7 76F7P 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX038T1E 77MRY 76F7P 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus RR P5520 SSDPF2KX076T1E 90M2J 76F7P 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 7R3K2 1.2.0 30.72 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 5JJFF 2.0.0 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF 5JJFF 2.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 5JJFF 2.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD 5JJFF 2.0.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe Add-in Cards
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC MZPLL1T6HEHP-000D3 06V6M 34C36 1.2.1 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC MZPLL3T2HMLS-00003 C2KKH 34C36 1.2.1 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC MZPLL6T4HMLS-000D3 604N5 34C36 1.2.1 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC MZPLL1T6HAJQ-000D3 FTX2R 3JJHC 1.2.2 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC MZPLL3T2HAJQ-00005 73KJ7 3JJHC 1.2.2 3.2 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC MZPLL6T4HMLA-000D3 FW2K0 3JJHC 1.2.2 6.4 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ1T6HBJR-00AD3 Y7D7D 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe AIC Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE MZPLJ6T4HALA-00AD3 91FXC 5CM3G 2.5.0 6.4 TB Cache, Capacity
2.2.5.2 - Azure Local Support Matrix for 16G (Dell 2503)
Model Supported Operating System
AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
AX-660 Windows Server 2025 Datacenter Azure Stack HCI-23H2
Base Components
Component Type Software Bundle Minimum Supported Version Supported Platforms Supported OS
BIOS Firmware DUP K77XK 2.5.4 AX-660 AX-760 NA
Chipset driver for 16G Intel platforms Driver DUP P7PJM 10.1.19928.8615 AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
iDRAC9 with Lifecycle Controller Firmware DUP 5MXXN 7.20.10.50 AX-660 AX-760 NA
Expander Storage Backplane Firmware DUP J9JW2 1.61 AX-760 NA
NVMe Switch Storage Backplane Firmware DUP WR74F 3.32 AX-760 NA
Non-expander Storage Backplane Firmware DUP GXH37 7.1 AX-760 NA
Non-expander Storage Backplane Firmware DUP 6Y9X7 7.1 AX-660 NA
iDRAC Service Module Firmware DUP 258RC 5.4.0.0 AX-660 AX-760 NA
CPLD Firmware DUP 503F0 1.2.6 AX-660 AX-760 NA
Network Adapters
Component Part Number SDDC Advanced Qualification RDMA Protocol Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported OS Supported Platforms
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card 5NN70 Management N/A MGPTR 23.11.4 KDMJJ 221.0.7.0d Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-660 AX-760
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 6JHVK 1.15.121.0 Windows Server 2022 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-660 AX-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP 6J1N1 Management Compute (Premium) Storage (Premium) iWARP,RoCEv2 89VV2 23.0.8 R71XY 1.15.302.0 Windows Server 2025 Datacenter AX-660 AX-760
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH 85F8F
Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH CD16M
Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP DWNRF
Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter PWH3C
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH VK88G
Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter Y4VV5
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH 8P2T2 Management Compute (Premium) Storage (Premium) RoCEv2 2CMVW 22.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-660 AX-760
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP F6FXM
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP 6XJXK Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-660 AX-760
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter DN78C
Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH R5WK9 Management Compute (Premium) Storage (Premium) RoCEv2 1H4PM 26.41.10.00 G6M58 24.4.26429 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2 AX-760
Network Switches
GPUs
GPU Model Vendor Description Part Number Firmware version Driver Version GPU-P capable Supported Platform Supported OS
A16 NVIDIA NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 D1P1T 94.07.54.00.45 553.62 Yes AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 H98K0 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
A2 NVIDIA NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 MG5JX 94.07.5B.00.55 553.62 Yes AX-660 AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU NG3PY 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L4 NVIDIA NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU V9XT2 95.04.29.00.06 553.62 Yes AX-660 AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L40 NVIDIA NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable VHNWT 95.02.39.00.01 553.62 Yes AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
L40S NVIDIA NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable 7WK28 95.02.66.00.02 553.62 Yes AX-760 Azure Stack HCI-22H2 Azure Stack HCI-23H2
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.
Storage Controllers
Component Dell Part Number Firmware Software Bundle Firmware Minimum Supported Version Driver Software Bundle Driver Minimum Supported Version Supported Platforms Supported OS
BOSS-N1 WW56V 33TD2 2.1.13.2033 Inbox Inbox AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
HBA355i K6MCJ Y99R5 24.15.14.00 M2P63 2.61.48.00 AX-660 AX-760 Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-22H2 Azure Stack HCI-23H2
SATA M.2 SSD Boot Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBA960TDZ PRV6C N71F4 1.6.0 960GB Boot
NVMe PCIe M.2 Read Intensive Micron 7400 MTFDKBG960TDZ 0V8F7 N71F4 1.6.0 960GB Boot
SAS 3.5" HDD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
HDD SAS 3.5 NA HGST Vela-A HUS726T4TALS200 NT1X2 J5K8G PU09 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SDA400NY 9VN79 99TKP EP02 4 TB Capacity
HDD SAS 3.5 NA HGST Vela-AP HUS728T8TAL5200 44YFV 8GM6M RS09 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG06 MG06SCA800EY FV725 4G5GY EH0D 8 TB Capacity
HDD SAS 3.5 NA HGST Leo-A He12 HUH721212AL5200 9HXK6 04PM5 NS11 12 TB Capacity
HDD SAS 3.5 NA WD Paris-C WUH721816AL5200 VF206 441CN US07 16 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST4000NM019B 10N7R 3P5N0 LW0B 4 TB Capacity
HDD SAS 3.5 NA Seagate Cimarron BP ST8000NM024B C5HD0 NM6GP LS0C 8 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA400NY FN2YX GTG81 EK06 4 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST12000NM006J M1C0T 92VPG PSLB 12 TB Capacity
HDD SAS 3.5 NA Seagate Evans BP ST16000NM006J 41DXR 92VPG PSLB 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG08SD MG08SDA800EY NJWMG 1RCYJ EL01 8 TB Capacity
HDD SAS 3.5 Read Intensive Seagate LongsPeak ST20000NM004D R3G03 56HWT GS07 20 TB Capacity
HDD SAS 3.5 NA Toshiba MG10SD MG10SDA800EY VJDMM 99TKP EP02 8 TB Capacity
HDD SAS 3.5 NA Seagate CimarronBP(EWP) DL4000NM019B F7DTR M7PKX LBW4 4 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA12TEY 0N96X 8829H EM05 12 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST12000NM007H FN7VR W6DKH SWS8 12 TB Capacity
HDD SAS 3.5 NA Toshiba MG09 MG09SCA16TEY MXC46 8829H EM05 16 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST16000NM007H R0G8W MGW24 SYS8 16 TB Capacity
HDD SAS 3.5 NA Toshiba MG10 MG10SCA20TEY NT45N 0H3CX EN04 20 TB Capacity
HDD SAS 3.5 NA WD Paris-D PR2 WUH722020BL5200 1D4CR YH8C3 VS18 20 TB Capacity
HDD SAS 3.5 NA Seagate Summit ST20000NM007H R5KP7 MGW24 SYS8 20 TB Capacity
HDD SAS 3.5 NA WD London DP WUH722420AL5200 MTTCF FN2N1 YS01 20 TB Capacity
SATA 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB019TZR 6J65H VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS1T9G3H2X069N 962FP 7XTPF DZ03 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH1T9HALT0D3 9F9Y6 107CV HG60 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L31T9HBLTAD3 0KYP4 537XV HJ62 1.92TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L31T9HELAAD3 PTD53 NF72T HL56 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK1T9TDS GYGVV KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK1T9TGA-1BC1ZABDA KXNX5 RJ0WY K003 1.92TB Capacity
SSD SATA 2.5 Read Intensive Intel S4520 SSDSC2KB038TZR KM4C4 VJPKG DL7C 3.84TB Capacity
SSD SATA 2.5 Read Intensive SK Hynix SE5110 HFS3T8G3H2X069N 3GDK0 7XTPF DZ03 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM883a MZ7LH3T8HALT0D3 5TVXD 107CV HG60 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893 MZ7L33T8HBLTAD3 GCN5W 537XV HJ62 3.84TB Capacity
SSD SATA 2.5 Read Intensive Samsung PM893a MZ7L33T8HELAAD3 D7V89 NF72T HL56 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5300 MTFDDAK3T8TDT 4H1RX R9YDC J408 3.84TB Capacity
SSD SATA 2.5 Read Intensive Micron 5400 MTFDDAK3T8TGA-1BC1ZABDA CHF46 JTW3W K403 3.84TB Capacity
SSD SATA 2.5 Mixed Use Intel S4620 SSDSC2KG019TZR 6XW3M VJPKG DL7C 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5130 HFS1T9G3E2X149N HCR09 4T2FN DG00 1.92TB Capacity
SSD SATA 2.5 Mixed Use SK Hynix SE5031 HFS1T9G32FEH-BA10A GKTF1 2CY65 DD02 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897a MZ7L31T9HENAAD3 GR4WN KHC8M HK56 1.92TB Capacity
SSD SATA 2.5 Mixed Use Samsung PM897 MZ7L31T9HBNAAD3 RRR7M Y4WVW HH62 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5300 MTFDDAK1T9TDT MMCDY KT63Y J008 1.92TB Capacity
SSD SATA 2.5 Mixed Use Micron 5400 MTFDDAK1T9TGB-1BC1ZABDA XRXX2 RJ0WY K003 1.92TB Capacity
SAS 2.5" SSD Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG800HCHQAD3 3CHC8 7MTXM DWG9 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Samsung PM1655 MZILG1T6HCJRAD3 5RJND 7MTXM DWG9 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG1T60 4TRHM T21WT C10E 1.6 TB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM6 KPM6XVUG800G NNGV4 NGPR2 BA48 800 GB Cache,Capacity
SSD SAS 2.5 Mixed Use Kioxia PM7 KPM7XVUG800G X96H8 T21WT C10E 800 GB Cache,Capacity
SAS 2.5" SSD Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG1T9HCJRAD3 NRR34 3MV58 DSG9 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG3T8HCLSAD3 9N32F 3MV58 DSG9 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Samsung PM1653 MZILG7T6HBLAAD3 Y8H7M 3MV58 DSG9 7.68 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG1T92 6K35K T21WT C10E 1.92 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG3T84 MT0R5 T21WT C10E 3.84 TB Capacity
SSD SAS 2.5 Read Intensive Kioxia PM7 KPM7XRUG7T68 7N1WT T21WT C10E 7.68 TB Capacity
NVMe 2.5" Cache or Capacity
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE MZWLJ1T6HBJR-00AD3 6GK00 5CM3G 2.5.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ3T2HBJRAD3 15TVC 5CM3G 2.5.0 3.2TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE MZWLJ6T4HALAAD3 F6V5P 5CM3G 2.5.0 6.4TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL3T20 97GR0 GMM6V 2.2.2 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM6 SP KCM6XVUL6T40 K916X GMM6V 2.2.2 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR3T2HBLS-00AD3 V69W3 5V3P7 2.5.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735 V2 SP 3WPD MZWLR6T4HALA-00AD3 H8D5M 5V3P7 2.5.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR1T6HCJRAD3 H8GHV 28J8R 1.1.1 1.6 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR3T2HCLSAD3 617H6 28J8R 1.1.1 3.2 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1735a MZWLR6T4HBLAAD3 9F6Y3 28J8R 1.1.1 6.4 TB Cache,Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG1T60 MP4F2 5JJFF 2.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG3T20 XFNX0 5JJFF 2.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XVUG6T40 8RJJ9 5JJFF 2.0.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS1T6GEJVX171N 1HYKD 9M65G 1.2.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS3T2GEJVX171N 9VWPD 9M65G 1.2.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Hynix PS1030 HFS6T4GEJVX171N PYMY6 9M65G 1.2.0 6.4 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO1T6HCJR-00AD3 FVC2P V7V0K 1.0.0 1.6 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO3T2HCLS-00AD3 FDNHD V7V0K 1.0.0 3.2 TB Cache, Capacity
NVMe PCIe 2.5 Mixed Use Samsung PM1745 MZWLO6T4HBLA-00AD3 64K9C V7V0K 1.0.0 6.4 TB Cache, Capacity
NVMe 2.5" Capacity Only
Type Drive Type Form Factor Endurance Vendor Series Model Device Part Number (P/N) Firmware Software Bundle Firmware Minimum Supported Version Capacity Use
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR3T8HBLS-00AD3 G5N65 5V3P7 2.5.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR7T6HALA-00AD3 DX74Y 5V3P7 2.5.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR3T8HCLSAD3 RJKM5 28J8R 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR7T6HBLAAD3 R1J8J 28J8R 1.1.1 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR15THBLAAD3 D4CJG 28J8R 1.1.1 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL1T92 N0VK0 GMM6V 2.2.2 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL3T84 8W2G5 GMM6V 2.2.2 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL7T68 VD0JX GMM6V 2.2.2 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CM6 KCM6XRUL15T3 J91CR GMM6V 2.2.2 15.36 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG1T92 M8YW0 5JJFF 2.0.0 1.92 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG3T84 XHYGF 5JJFF 2.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG7T68 VV2M7 5JJFF 2.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Mixed Use Kioxia CM7 KCM7XRUG15T3 DX2PD 5JJFF 2.0.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG3T84 N1MK1 HV8P1 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS1T9GEJVX171N 7GGK1 9M65G 1.2.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS3T8GEJVX171N J4TDK 9M65G 1.2.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS7T6GEJVX171N 2533N 9M65G 1.2.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PS1010 HFS15T3EJVX171N 8TY8G 9M65G 1.2.0 15.36 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS960GECTX088N WR2FG T1XKD 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 SDF1E86DAB YNGYD HV8P1 2.0.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC960TFR-1BC1ZABDA KXT48 RPTG2 1.3.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC960TGP-1BK1JABDA G7NCH HW0R3 1.1.0 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL2960HCJR-00AD3 6HYWM XMFKX 1.1.1 960 GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733a MZWLR1T9HCJR-00AD3 8PMRM 28J8R 1.1.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1733 V2 MZWLR1T9HBJR-00AD3 WPR17 5V3P7 2.5.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL21T9H TGYF5 XMFKX 1.1.1 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC1T9TFR JH61J RPTG2 1.3.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC1T9TGP M7RHM HW0R3 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8110 HFS1T9GEETX099N 147DR TDGKY 1.1.0 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC3T8TFR-1BC1ZABDA NDK2D RPTG2 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD7 KCD7XRUG3T84 RFYP9 K6597 2.0.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Hynix PE8010 HFS3T8GECTX088N V6WP5 T1XKD 1.3.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL23T8HCLSAD3 P7G03 XMFKX 1.1.1 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC3T8TGP-1BK1JABDA GT3F3 HW0R3 1.1.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Intel Arbordale Plus R P5316 SSDPF2NV307TZ 4KCVT 4XT8T 1.6.0 30.72 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO3T8HCLS-00AD3 9GXVF V7V0K 1.0.0 3.84 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO7T6HBLA-00AD3 DNPR4 V7V0K 1.0.0 7.68 TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG1T92 NNKCT HV8P1 2.0.1 1.92 TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM9A3 MZQL27T6HBLAAD3 30FX3 XMFKX 1.1.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7450 MTFDKCC7T6TFR-1BC1ZABDA 91KYJ RPTG2 1.3.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Micron 7500 MTFDKCC7T6TGP-ABK1JABYYES RTJFW HW0R3 1.1.0 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive Kioxia CD8 KCD8XRUG7T68 MXD8J HV8P1 2.0.1 7.68TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS960GEETX099N 26WJ0 TDGKY 1.1.0 960GB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO1T9HCJR-00AD3 G64N5 V7V0K 1.0.0 1.92TB Capacity
NVMe PCIe 2.5 Read Intensive SK Hynix PE8110 HFS3T8GEETX099N 2V97V TDGKY 1.1.0 3.84TB Capacity
NVMe PCIe 2.5 Read Intensive Samsung PM1743 MZWLO15THBLA-00AD3 VPWMR V7V0K 1.0.0 15.36TB Capacity
2.2.5.3 - Azure Local Golden Images (Dell 2503)
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Local Golden Images for Solution version 10.*
Azure Local Golden Images for Solution version 11.*
2.2.6 - Azure Stack HCI Support Matrix (Archive)
2.2.6.1 - Azure Stack HCI Firmware and Driver Matrix for Legacy Windows Server Operating Systems (Windows Server 2016)
Introduction
This matrix is for Windows Server operating systems that have exited Microsoft mainstream support. This Windows Server operating system is no longer being validated by Dell for use with hyperconverged cluster deployments. The table in the below link is a snapshot of the last firmware and driver versions that were validated by Dell engineering for use with this legacy Windows Server version.
Windows Server 2016 - Microsoft Lifecycle | Microsoft Learn
Customers that are still running this Windows Server version for their hyperconverged cluster deployments are encouraged to perform an in-place upgrade to the Windows Server 2022 operating system per instructions at the following link.
Perform a Feature Update of Windows Server | Microsoft Learn
Storage Spaces Direct Ready Nodes and AX nodes Supported Firmware versions
Component
Type
Category
Software Bundle
Minimum Supported Version
Supported Systems
BIOS
Firmware DUP
BIOS
W77H1
2.16.1
AX-640
R640
AX-740xd
R740xd
BIOS
Firmware DUP
BIOS
CKFTD
2.16.1
R440
BIOS
Firmware DUP
BIOS
VHNTJ
2.16.1
R740xd2
BIOS
Firmware DUP
BIOS
61GYN
2.9.3
AX-6515
BIOS
Firmware DUP
BIOS
C45MX
2.9.3
AX-7525
BIOS
Firmware DUP
BIOS
G7K8G
1.8.2
AX-650
AX-750
iDRAC9 with Lifecycle Controller
Firmware DUP
BMC
KMYV9
6.10.00.00
All
Non-expander Storage Backplane
Firmware DUP
Storage-Backplane
VV85D
4.35
AX-640
AX-740xd
R640
R740xd
Non-expander Storage Backplane
Firmware DUP
Storage-Backplane
6NNVP
3.72
AX-7525
AX-650
AX-750
NVMe Switch Storage Backplane
Firmware DUP
Storage-Backplane
5XJWN
1.05
AX-750
Expander Storage Backplane
Firmware DUP
Storage-Backplane
H9PV3
1.20
AX-750
AX-7525
Expander Storage Backplane
Firmware DUP
Storage-Backplane
60K1J
2.52
All
Intel S3520, M.2, SSD, RI, 240 GB, 480 GB
Firmware DUP
BOSS (Boot)
CHJGV
DL43
All
Micron 5100, M.2, SSD, 240 GB, 480 GB
Firmware DUP
BOSS (Boot)
YM8KY
E013
All
Micron 5300, M.2, SSD, 240 GB, 480 GB
Firmware DUP
BOSS (Boot)
PWVX5
J004
All
CPLD
Firmware DUP
CPLD
1GW62
1.0.10
R440
CPLD
Firmware DUP
CPLD
9N4DH
1.0.6
AX-640
R640
CPLD
Firmware DUP
CPLD
G65GH
1.1.4
AX-740xd
R740xd
CPLD
Firmware DUP
CPLD
R13D8
1.0.4
R740xd2
CPLD
Firmware DUP
CPLD
79XGF
1.0.7
AX-6515
CPLD
Firmware DUP
CPLD
XTPX5
1.1.15
AX-7525
CPLD
Firmware DUP
CPLD
N9YTC
1.0.8
AX-650
AX-750
iDRAC Service Module OS DUP
Application
iSM
XJ9W8
4.3.0.0
All
(1) The "Non-expander Storage Backplane" is applicable only to R640 12-drive and R740xd 18-drive chassis configurations.
Storage Spaces Direct Ready Nodes and AX nodes Firmware and Drivers for Windows Server 2016
Component
Category
Part Number
Firmware
Drivers
Software Bundle
Minimum Supported Version
Software Bundle
Minimum Supported Version
Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC
Mellanox ConnextX-4 Lx Dual Port 25GbE DA/SFP Network Adapter, LP
Mellanox ConnextX-4 Lx Dual Port 25GbE DA/SFP Network Adapter, FH
Network / RDMA
R887V
20NJD
MRT0D
YTPJW
14.31.20.06
F3Y6R
02.80.02 - Installer
2.80.25134.0 - Driver
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH
Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH
Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP
Network / RDMA
71C1T
9FTMY
TDNNT
V5DG9
3CJ0V
16.31.20.06
F3Y6R
02.80.02 - Installer
2.80.25134.0 - Driver
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP
Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH
Network / RDMA
F6FXM
8P2T2
1XPGP
22.31.20.06
F3Y6R
02.80.02 - Installer
2.80.25134.0 - Driver
Qlogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP
QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH
Network / iWARP
4KF8J
415DX
51GRM
TD0M9
15.20.16
RYX52
35.20.14 - Installer
8.53.1.0 - Driver
QLogic FastLinQ 41162 Dual Port 10GbE BASE-T & Dual Port 1GbE BASE-T, rNDC
Network / NDC
0D1WT
TD0M9
15.20.16
RYX52
35.20.14 - Installer
8.53.1.0 - Driver
QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC
Network / NDC
XVVY1
TD0M9
15.20.16
RYX52
35.20.14 - Installer
8.53.1.0 - Driver
QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC
Network / NDC
X1TD1
TD0M9
15.20.16
RYX52
35.20.14 - Installer
8.53.1.0 - Driver
Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet, NDC
Network / NDC
6VDPG
DK4G2
20.0.17
284J6
20.0.0 - Installer
1.13.104.0 - Driver
Qlogic 57800 2x10Gb BT + 2x1Gb BT NDC
QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC
Network / NDC
G8RPD
165T0
899FK
15.20.13
MJP9W
35.20.04 - Installer
Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card
Network / NDC
KJMHJ
M18WH
21.80.9
49X84
21.80.3 - Installer
214.0.0.6 - Driver
Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC
Network / NDC
NWMNX
YPXWJ
21.85.21.91
XYJ8C
218.0.169.0 - Installer
21.80.16.60 - Driver
Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card
Network / NDC
WC9TR
YPXWJ
21.85.21.91
XYJ8C
218.0.169.0 - Installer
21.80.16.60 - Driver
Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card
Network / NDC / OCP
930PP
YPXWJ
21.85.21.91
XYJ8C
218.0.169.0 - Installer
21.80.16.60 - Driver
HBA330 Controller, 12Gps Mini Card
HBA330 Controller, 12Gps Mini Card, LP
Storage-HBA
P2R3R
J7TNV
124X2
NKNVC
16.17.01.00
P1NP6
2.51.25.01 - Windows Server 2016
BOSS-S1
BOSS-S1
2MFVD
3P39V
2.5.13.3024
8KKVC
1.2.0.1052
Chipset driver for Intel platforms
Chipset
Not applicable
Not applicable
Not applicable
MPXXJ
10.1.18807.8279
SAS 2.5” HDD Drives - Capacity Only
Form Factor
Type
Vendor
Model
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
2.5"
7.2K 12Gbps SAS HDD
Seagate
Avenger
ST2000NX0463
TMVN7
GW3V7
NT32
2 TB
Capacity
2.5"
10K 12 Gbps SAS HDD
Seagate
Skybolt
DL2400MM0159
RWR8F
HYJ6K
ST5C
2.4 TB
Capacity
2.5"
10K 12 Gbps SAS HDD
Toshiba
AL15SE
AL15SEB24EQY
F9NWJ
0T1RG
EF06
2.4 TB
Capacity
2.5"
10K 12 Gbps SAS HDD
Seagate
Skybolt
ST2400MM0159
36YG1
DY8C3
ST76
2.4 TB
Capacity
SATA 2.5” HDD Drives - Capacity Only
Form Factor
Type
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
2.5"
7.2K 6Gbps SATA HDD
Seagate
Avenger
ST2000NX0423
VR92X
GMW4P
NB33
2 TB
Capacity
SATA 3.5” HDD Drives - Capacity Only
Form Factor
Type
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
3.5"
HDD
Hitachi
Aries K Plus
HUS726020ALA610
HUS726040ALA610
8NP2N
61FFW
X59KC
KV45
2 TB
4 TB
Capacity
3.5"
HDD
Hitachi
Rainier MLK
HUS722T2TALA600
V9H6C
V3DJM
MU03
2 TB
Capacity
3.5"
HDD
Toshiba
Tomcat R
MG04ACA200NY
MG04ACA400NY
NPVM6
95M6K
V47C4
FK5D
2 TB
4 TB
Capacity
3.5"
HDD
Seagate
Nemo
ST2000NM0018-2F3130
W8FW5
CMK5N
EA04
2 TB
Capacity
3.5"
HDD
Seagate
Makara BP
ST2000NM0145-2DC104
ST4000NM0265-2DC107
WG9R0
MWHY9
M5GJ1
DB34
2 TB
4 TB
Capacity
3.5"
HDD
Hitachi
Vela-A
HUS726T4TALA6L0
YH3T9
3CFT0
PV07
4 TB
Capacity
3.5"
HDD
Hitachi
Vela-AP
HUS728T8TALE6L0
1WMVC
N26JT
RT07
8 TB
Capacity
3.5"
HDD
Hitachi
Libra HE10
HUH721008ALE600
KRV2W
H12N2
LT21
8 TB
Capacity
3.5"
HDD
Seagate
Makara Plus
ST8000NM0205-2FF112
92MDW
MR6RH
PB53
8 TB
Capacity
3.5"
HDD
Toshiba
MG06
MG06ACA800EY
9X09C
PT7D8
GA09
8 TB
Capacity
3.5"
HDD
Hitachi
Leo-A He12
HUH721212ALE600
T2YHT
0HF04
NT10
12 TB
Capacity
3.5"
HDD
Toshiba
MG07
MG07ACA12TEY
753F0
0942Y
GB03
12 TB
Capacity
3.5"
HDD
Toshiba
MG08AC
MG08ACA16TEY
HPGJ4
MGF80
GC02
16 TB
Capacity
3.5"
HDD
Toshiba
MG08AD
MG08ADA400NY
W2M9N
7NJXF
GD03
4 TB
Capacity
3.5"
HDD
Seagate
Cimarron
ST4000NM016A-2HZ130
ST8000NM012A-2KE131
XPJ47
F4JXT
179WV
V1521
CAJC
CALD
4 TB
8 TB
Capacity
3.5"
HDD
Seagate
Cimarron BP
ST4000NM018B-2TF130
ST8000NM023B-2TJ133
6KR2M
J7W80
J4X0T
4P5X3
LC09
LA0A
4 TB
8 TB
Capacity
SAS 3.5” HDD Drives - Capacity Only
Form Factor
Type
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
3.5"
HDD
Hitachi
Aries K Plus
HUS726020ALS210
HUS726040ALS210
VH6FW
X4FKY
68X4C
KU45
2 TB
4 TB
Capacity
3.5"
HDD
Toshiba
Tomcat R
MG04SCA20ENY
MG04SCA40ENY
HHX14
1MVTT
RG9MK
EG03
2 TB
4 TB
Capacity
3.5"
HDD
Seagate
Makara BP
ST2000NM0155
ST4000NM0295
7RCGV
5JH5X
3CRY1
DT32
2 TB
4 TB
Capacity
3.5"
HDD
Hitachi
Vela-A
HUS726T4TALS200
NT1X2
1DM5F
PU07
4 TB
Capacity
3.5
HDD
Hitachi
Vela-AP
HUS728T8TAL5200
44YFV
6JJPV
RS07
8 TB
Capacity
3.5"
HDD
Hitachi
Libra HE10
HUH721008AL5200
KRDKK
MGW91
LS21
8 TB
Capacity
3.5"
HDD
Seagate
Makara Plus
ST8000NM0185
M40TH/VFP4M
6421F
PT55
8 TB
Capacity
3.5"
HDD
Toshiba
MG06
MG06SCA800EY
FV725
4G5GY
EH0D
8 TB
Capacity
3.5"
HDD
Hitachi
Leo-A He12
HUH721212AL5200
9HXK6
230YX
NS10
12 TB
Capacity
3.5"
HDD
Toshiba
MG07
MG07SCA12TEY
DK7C9/KFJ7G
GT72W
EI0C
12 TB
Capacity
3.5"
HDD
Seagate
Evans
ST12000NM009G
7KT9W
NJ4NN
ESL7
12 TB
Capacity
3.5"
HDD
Seagate
Mobula BP
ST12000NM0158
YMN53
VTX9C
RSL5
12 TB
Capacity
3.5"
HDD
Toshiba
MG08SC
MG08SCA16TEY
8MG73
9N3RR
EJ09
16 TB
Capacity
3.5"
HDD
Toshiba
MG08SC
MG08SCA16TEY
4N7V0
9N3RR
EJ09
16 TB
Capacity
3.5"
HDD
Toshiba
MG08SC
MG08SCA16TEY
24HF9
9N3RR
EJ09
16 TB
Capacity
3.5"
HDD
Seagate
Evans
ST16000NM010G
CNXPV
NJ4NN
ESL7
16 TB
Capacity
3.5"
HDD
WD
Paris-C
WUH721816AL5200
VF206
19MP7
US06
16 TB
Capacity
3.5"
HDD
Seagate
Cimarron
ST4000NM017A
ST8000NM014A
KRM6X
0N660
WTX15
PRFRJ
CSJA
CSLC
4 TB
8 TB
Capacity
3.5
HDD
Seagate
Cimarron BP
ST4000NM019B ST8000NM024B
10N7R
C5HD0
912Y9
DTGXD
LW0A
LS0A
4 TB
8 TB
Capacity
3.5
HDD
Toshiba
MG08SD
MG08SDA400NY
FN2YX
N5XN3
EK05
4 TB
Capacity
SATA 2.5” SSD Drives - Cache or Capacity
Endurance
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Mixed Use
Toshiba
HK4
THNSF8800CCSE
THNSF81D60CSE
VCRY6
DMF5Y
H3XHN
DACB
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Micron
5300
MTFDDAK960TDT
MTFDDAK1T9TDT
XMWMK
MMCDY
X5R54
J004
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Samsung
SM863a
MZ7KM960HMJP0D3
MZ7KM1T9HMJP0D3
DD4G0
K5P0T
97D8J
GD57
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Samsung
SM883
MZ7KH960HAJR0D3
MZ7KH1T9HAJR0D3
YDHYX
71K37
3J3JR
HF58
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Intel
S4600
SSDSC2KG960G7R
SSDSC2KG019T7R
TR3MY
MWKF2
V141M
DL5C
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Intel
S4610
SSDSC2KG960G8R
SSDSC2KG019T8R
X31G3
F8N2K/55J8H
2674V
DL69
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Micron
5200
MTFDDAK960TDN
MTFDDAK1T9TDN
HY1F8
XKF5Y
H72VG
F005
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Toshiba
HK6-V
KHK6YVSE960G
KHK6YVSE1T92
XW4D1
0DXJ7
W0YR1
DBC4
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Hynix
SE5031
HFS960G32FEH-BA10A
HFS1T9G32FEH-BA10A
7GR2K
GKTF1
7X9WV
DD02
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Intel
Youngsville-RR
SSDSC2KG960GZR
SSDSC2KG019TZR
8MHYH
8RXV5
PN1T8
DL70
960 GB
1.92 TB
Cache, Capacity
Mixed Use
Samsung
PM897
MZ7L3960HBLTAD3
MZ7L31T9HBNAAD3
MZ7L33T8HBNAAD3
96KT6
RRR7M
N04DW
2PV21
HH53
960 GB
1.92 TB
3.84 TB
Cache, Capacity
SATA 2.5” SSD Drives - Capacity Only
Endurance
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Read Intensive
Micron
5200
MTFDDAK1T9TDD
VJ36D
H72VG
F005
1.92 TB
Capacity Only
Read Intensive
Micron
5300
MTFDDAK1T9TDS
GYGVV
X5R54
J004
1.92 TB
Capacity Only
Read Intensive
Toshiba
HK6-R
KHK6YRSE1T92
KHK6YRSE3T84
919J7
8PYG5
W0YR1
DBC4
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Samsung
PM883a
MZ7LH1T9HALT0D3
9F9Y6
882YH
HG58
1.92 TB
Capacity Only
Read Intensive
Samsung
PM883
MZ7LH1T9HMLT0D3
Y24T6
93P7P
HE59
1.92 TB
Capacity Only
Read Intensive
Hynix
SE4011
HFS1T9G32FEH-7A10A
0XMV9
MFCH2
DE07
1.92 TB
Capacity Only
Read Intensive
Intel
S4510
SSDSC2KB019T8R
33R2T
2674V
DL69
1.92 TB
Capacity Only
Read Intensive
Intel
S4500
SSDSC2KB019T7R
SSDSC2KB038T7R
XCN15
3RRN8
V141M
DL5C
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Intel
S4510
SSDSC2KB038T8R
1RHK2
2674V
DL69
3.84 TB
Capacity Only
Read Intensive
Samsung
PM883
MZ7LH3T8HMLT0D3
FYP5F
93P7P
HE59
3.84 TB
Capacity Only
Read Intensive
Samsung
PM883a
MZ7LH3T8HALT0D3
5TVXD
882YH
HG58
3.84 TB
Capacity Only
Read Intensive
Hynix
SE4011
HFS3T8G32FEH-7410A
D6C0R
MFCH2
DE07
3.84 TB
Capacity Only
Read Intensive
Micron
5300
MTFDDAK3T8TDT
4H1RX
PXMD3
J404
3.84 TB
Capacity Only
Read Intensive
Hynix
SE5110
HFS1T9G3H2X069N
HFS3T8G3H2X069N
962FP
3GDK0
8KVKG
DZ02
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Intel
Youngsville-RR
SSDSC2KB960GZR
SSDSC2KB019TZR
SSDSC2KB038TZR
F6H8H
VYYW8
WNPN1
PN1T8
DL70
960 GB
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Samsung
PM893
MZ7L31T9HBLTAD3
MZ7L33T8HBLTAD3
0KYP4
GCN5W
5MKJ8
HJ53
1.92 TB
3.84 TB
Capacity Only
SAS 2.5” SSD Drives - Cache or Capacity
Endurance
Vendor
Series
Model
Supported Config
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Write Intensive
Toshiba
Phoenix M4
PX05SMB080Y
PX05SMB160Y
Hyb, AF
CN3JH
GVTYD
1DJXX
AS10
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Toshiba
Phoenix M4
PX05SVB096Y
PX05SVB192Y
PX05SVB384Y
Hyb, AF
503M7
V0K7V
3DDFT
1DJXX
AS10
960 GB
1.92 TB
3.84 TB
Cache, Capacity
Write Intensive
Toshiba
Phoenix M5-M
KPM5XMUG800G
KPM5XMUG1T60
Hyb, AF
DHRVV
W9G88
4P9DW
B026
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Samsung
PM1645a
MZILT800HBHQ0D3
MZILT1T6HBJR0D3
Hyb, AF
GW8T1
3TCV6
VJY6V
DWA4
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Samsung
PM1645
MZILT1T6HAJQ0D3
Hyb, AF
DR0HX
C9JP2
DWF8
1.6 TB
Cache, Capacity
Mixed Use
WD
Bear Cove Quantum
WUSTR6480BSS200
WUSTR6416BSS200
Hyb, AF
6VJC9
6NF96
X95FJ
G130
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Toshiba
Phoenix M5-V
KPM5XVUG960G
KPM5XVUG1T92
KPM5XVUG3T84
Hyb, AF
WFGTH
2WVYG
91W3V
4P9DW
B026
960 GB
1.92 TB
3.84 TB
Cache, Capacity
Write Intensive
Kioxia
PM6
KPM6XMUG800G
KPM6XMUG1T60
Hyb, AF
H6GCD
5GDXH
6K5N9
BA0D
800 GB
1.6 TB
Cache, Capacity
Mixed Use
Kioxia
PM6
KPM6XVUG800G
KPM6XVUG1T60
KPM6XVUG6T40
Hyb, AF
JTKH5
GD3N0
6NW3J
6K5N9
BA0D
800 GB
1.6 TB
6.4 TB
Cache, Capacity
Mixed Use
Kioxia
PM6, FIPS
KPM6WVUG960G
KPM6WVUG1T92
KPM6WVUG3T84
Hyb, AF
WMWKG
DHWH5
81H9C
376CY
BD0D
960 GB
1.92 TB
3.84 TB
Cache, Capacity
SAS 2.5” SSD Drives - Capacity Only
Endurance
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Read Intensive
WD
Bear Cove Plus
WUSTR1519ASS200
WUSTR1538ASS200
5ND33
YW17N
358PN
K960
1.92 TB
3.84 TB
Capacity Only
Read Intensive
WD
Bear Cove Quantum
WUSTVA119BSS200
WUSTVA138BSS200
02X38
FP1KF
1GGR2
G10A
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Samsung
PM1643
MZILT1T9HAJQ0D3
MZILT3T8HALS0D3
MZILT7T6HMLA0D3
F0VFY
X8F87
RVYD5
J3RRK
DSF8
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Samsung
PM1643a
MZILT1T9HBJR0D3
MZILT3T8HBLS0D3
MZILT7T6HALA0D3
TMTW9
CRNPH
84C40
D7RNT
DSA4
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Samsung
PM1633a
MZILS3T8HMLH0D3
JR1HP
XNGNT
DSLA
3.84 TB
Capacity Only
Read Intensive
Toshiba
Phoenix M5-R
KPM5XRUG1T92
KPM5XRUG3T84
TDNP7
N85XX
4P9DW
B026
1.92 TB
3.84 TB
Capacity Only
Read Intensive
Toshiba
Phoenix M4
PX05SRB384Y
XCRDV
1DJXX
AS10
3.84 TB
Capacity Only
Read Intensive
Kioxia
PM6
KPM6XRUG1T92
KPM6XRUG3T84
KPM6XRUG7T68
4CN85
H9TT5
PD02Y
2N1R6
BA0B
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Kioxia
PM6
KPM6WRUG1T92
KPM6WRUG3T84
7F2D1
FH1W9
376CY
BD0D
1.92 TB
3.84 TB
Capacity Only
Value SAS 2.5” SSD Drives - Cache or Capacity
Endurance
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Mixed Use
Toshiba
Phoenix RM5
KRM5XVUG3T84
X78JM
12D7W
B70C
3.84 TB
Cache, Capacity
Mixed Use
Seagate
LangeBP
XS3840LE70154
NWGX3
NX13G
4D0C
3.84 TB
Cache, Capacity
Mixed Use
Seagate
LangeBP,SED
XS960LE70134
XS1920LE70134
XS3840LE70134
2RDWT
N6DRV
YM9HP
G04C8
4S0C
960 GB
1.92 TB
3.84 TB
Cache, Capacity
Mixed Use
Kioxia
RM6,SED
KRM6VVUG960G
KRM6VVUG1T92
KRM6VVUG3T84
42XXC
N15JP
FXYGR
3P4FR
BJ02
960 GB
1.92 TB
3.84 TB
Cache, Capacity
Read Intensive
Toshiba
Phoenix RM5
KRM5XRUG7T68
5XD2F
12D7W
B70C
7.68 TB
Capacity Only
Read Intensive
Seagate
Lange
XS7680SE70074
2PKRH
H3VHX
EC16
7.68 TB
Capacity Only
Read Intensive
Seagate
LangeBP
XS7680SE70154
5KW0F
NX13G
4D0C
7.68 TB
Capacity Only
Read Intensive
Seagate
LangeBP,SED
XS1920SE70134
XS3840SE70134
XS7680SE7013
K9T53
4KPKF
2THYF
G04C8
4S0C
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Kioxia
RM6,SED
KRM6VRUG1T92
KRM6VRUG3T84
KRM6VRUG7T68
1FGWG
XNXD2
5MHY8
3P4FR
BJ02
1.92 TB
3.84 TB
7.68 TB
Capacity Only
NVMe Drives - Cache or Capacity
NOTE
Intel Optane P4800x is supported only on the R640 Storage Spaces Direct Ready Node.
Platform
Vendor
Form Factor
Description
Model Number
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
NVMe only
Intel
2.5"
Optane P4800x SSD/NVMe, 375 GB U.2 2.5" SFF
SSDPE21K375GAT
3DM57
HD2YY
E201DP38
375 GB
Cache, Capacity
NVMe only
Samsung
2.5"
PM1725A
MZWLL1T6HEHP-000D3
MZWLL3T2HMJP-000D3
MZWLL6T4HMLS-000D3
JD6CH
JDMHM
Y3XT2
34C36
1.2.1
1.6 TB
3.2 TB
6.4 TB
Cache, Capacity
NVMe only
Samsung
2.5"
PM1725b
MZWLL1T6HAJQ-000D3
MZWLL3T2HAJQ-000D3
MZWLL6T4HMLA-000D3
4WDXY
K60N7
08NMX
3F3N1
1.2.2
1.6 TB
3.2 TB
6.4 TB
Cache, Capacity
NVMe only
Intel
2.5"
P4600
SSDPE2KE016T7T
SSDPE2KE032T7T
F5P84
MCV6J
CR0HC
QDV1DP17
1.6 TB
3.2 TB
Cache, Capacity
NVMe only
Intel
2.5"
P4610
SSDPE2KE016T8T
SSDPE2KE032T8T
SSDPE2KE064T8T
58V30
2CN1T
X27HY
GD4X4
VDV1DP25
1.6 TB
3.2 TB
6.4 TB
Cache, Capacity
NVMe only
KIOXIA
2.5"
CM6,FIPS
Dell Ent NVMe FIPS CM6 MU 1.6 TB
G7N00
T79D5
1.2.0
1.6 TB
Cache, Capacity
NVMe only
Samsung
2.5"
PM1735
Dell Ent NVMe AGN MU U.2 1.6 TB
6GK00
RP8RC
2.3.0
1.6 TB
Cache, Capacity
NVMe only
Samsung
2.5"
PM1735 V2
Dell Ent NVMe v2 AGN MU U.2 1.6 TB
Dell Ent NVMe v2 AGN MU U.2 3.2 TB
Dell Ent NVMe v2 AGN MU U.2 6.4 TB
0MNMV
V69W3
H8D5M
TRCC6
2.3.0
1.6 TB
3.2 TB
6.4 TB
Cache, Capacity
NVMe only
Kioxia
2.5"
CM6 SP
Dell Ent NVMe CM6 MU 1.6 TB
Dell Ent NVMe CM6 MU 3.2 TB
Dell Ent NVMe CM6 MU 6.4 TB
P03YC
97GR0
K916X
511TX
2.1.8
1.6 TB
3.2 TB
6.4 TB
Cache, Capacity
NVMe only
Intel
2.5"
P5600 SP
Dell Ent NVMe P5600 MU U.2 1.6 TB
Dell Ent NVMe P5600 MU U.2 3.2 TB
C9X5T
PRKTM
J7FTF
1.2.4
1.6 TB
3.2 TB
Cache, Capacity
NVMe only
Intel
2.5"
Arbordale Plus RR
SSDPF2KE016T1E
SSDPF2KE032T1E
82TVJ
TY3M5
J55N8
1.0.0
1.6 TB
3.2 TB
Cache, Capacity
NVMe Drives - Capacity Only
NOTE
Toshiba CD5 960 GB capacity is supported only on the R640 Storage Spaces Direct Ready Node.
Endurance
Vendor
Series
Model
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
Read Intensive
Toshiba
CD5
KCD5XLUG960G
KCD5XLUG3T84
DRC9H
17C57
T79D5
1.2.0
960 GB
3.84 TB
Capacity Only
Intel
P4510
SSDPE2KX040T8T
5GMK0
GD4X4
VDV1DP25
4 TB
Capacity Only
Read Intensive
KIOXIA
CM6
Dell Ent NVMe FIPS CM6 RI 1.92 TB
TXP72
T79D5
1.2.0
1.92 TB
Capacity Only
Read Intensive
Intel
P5500
Dell Ent NVMe P5500 RI U.2 1.92 TB
Dell Ent NVMe P5500 RI U.2 3.84 TB
Dell Ent NVMe P5500 RI U.2 7.68 TB
WPP9G
KRT3G
RNN67
XXN1D
1.2.3
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Samsung
PM1733 V2
Dell Ent NVMe v2 AGN RI U.2 3.84 TB
Dell Ent NVMe v2 AGN RI U.2 7.68 TB
G5N65
DX74Y
FJK0C
2.2.0
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Kioxia
CM6,SP
KCM6XRUL1T92
KCM6XRUL3T84
KCM6XRUL7T86
N0VK0
8W2G5
VD0JX
511TX
2.1.8
1.92 TB
3.84 TB
7.68 TB
Capacity Only
Read Intensive
Intel
Arbordale Plus RR
SSDPF2KX019T1E
SSDPF2KX038T1E
SSDPF2KX076T1E
0HVC7
77MRY
90M2J
J55N8
1.0.0
1.92 TB
3.84 TB
7.68 TB
Capacity Only
NVMe PCIe Add In Card (AIC) - Cache or Capacity
Platform
Vendor
Form Factor
Description
Model Number
Device Part Number (P/N)
Software Bundle
Minimum Supported Version
Capacity
Use
NVMe only
Samsung
PCIe AIC
PM1725A
MZPLL1T6HEHP-000D3
MZPLL6T4HMLS-000D3
06V6M
604N5
34C36
1.2.1
1.6 TB
6.4 TB
Cache, Capacity
NVMe only
Samsung
PCIe AIC
PM1725b
MZPLL1T6HAJQ-000D3
MZPLL6T4HMLA-000D3
FTX2R
FW2K0
3F3N1
1.2.2
1.6 TB
6.4 TB
Cache, Capacity
NVMe only
Samsung
PCIe AIC
PM1735
MZPLJ1T6HBJR-00AD3
MZPLJ6T4HALA-00AD3
Y7D7D
91FXC
RDKVC
2.4.0
1.6 TB
6.4 TB
Cache, Capacity
2.3 - BIOS and iDRAC configuration recommendations
BIOS Configuration
The following table lists the BIOS configuration settings for server nodes implemented as Storage Spaces Direct cluster nodes.
BIOS Section
BIOS Token
PE Default Value
AX Value
Platform
Processor Settings
Virtualization Technology
Enabled
Enabled
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Processor Settings
x2APIC Mode
Enabled
Enabled
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Processor Settings
NUMA Nodes Per Socket
1
4
AX-6515 AX-7525
Processor Settings
Dell Controlled Turbo Setting (Optional)
Disabled
Enabled
AX-760 AX-750 AX-650 AX-4510c AX-4520c
Integrated Devices
SR-IOV Global Enable
Disabled
Enabled
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
System Profile Settings
Systems Profile
Performance Per Watt (DAPC)
Performance
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
TPM Security
Off
On
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
AC Power Recovery
NA
On
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
AC Power Recovery Delay
NA
Random
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
Secure Boot
Disabled
Enabled
AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 AX-760 AX-4510c AX-4520c
Processor Settings
Kernel DMA Protection
Disabled
Enabled
AX-650 AX-750 AX-7525 AX-760 AX-4510c AX-4520c
Processor Settings
Secure Memory Encryption
Disabled
Enabled
AX-7525
Processor Settings
Transparent Secure Memory Encryption
Disabled
Enabled
AX-7525
Systems Security
TPM PPI Bypass Provision
Disabled
Enabled
AX-650 AX-750 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
TPM PPI Bypass Clear
Disabled
Enabled
AX-650 AX-750 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
TPM2 Algorithm Selection
SHA1
SHA256
AX-650 AX-750 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
Intel TXT/AMD DRTM
Off
On
AX-650 AX-750 AX-7525 AX-760 AX-4510c AX-4520c
Systems Security
SMM Security Mitigation
Disabled
Enabled
AX-7525 AX-760 AX-4510c AX-4520c
iDRAC Configuration
The following table lists the iDRAC settings for nodes in an Azure Local instance.
Setting Category
Setting Name
Desired Value
Network Settings
Enable NIC
Enable
NIC Selection
Dedicated
IPMI Settings
Enable IPMI Over LAN*
Enable
Power Configuration
Redundancy Policy
Input Power Redundant
Enable Hot Spare
Enabled
Primary Power Supply Unit
PSU1
*Required only if you plan to use SCVMM based management of bare-metal server.
3 - References