This is the multi-page printable view of this section. Click here to print.
Azure Local Support Matrix (Dell 2512)
1 - Azure Local Support Matrix for 14G-15G (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Supported Platforms
| Model | Supported Operating System |
|---|---|
| AX-640 | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| AX-740xd | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| AX-6515 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| AX-7525 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| AX-650 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| AX-750 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
Base Components
| Component | Type | Software Bundle | Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|
| BIOS | Firmware DUP | 9M80P | 2.25.0 | AX-640 AX-740xd | NA |
| BIOS | Firmware DUP | 74JWM | 2.22.0 | AX-6515 | NA |
| BIOS | Firmware DUP | 2KY3W | 2.22.0 | AX-7525 | NA |
| BIOS | Firmware DUP | 8388K | 1.19.2 | AX-650 AX-750 | NA |
| iDRAC9 with Lifecycle Controller | Firmware DUP | VP556 | 7.00.00.183 | AX-640 AX-740xd | NA |
| iDRAC9 with Lifecycle Controller | Firmware DUP | KYWDC | 7.20.80.50 | AX-6515 AX-7525 AX-650 AX-750 | NA |
| Non-expander Storage Backplane | Firmware DUP | VV85D | 4.35 | AX-6515 AX-640 AX-740xd | NA |
| Non-expander Storage Backplane | Firmware DUP | G69W6 | 7.16 | AX-7525 AX-750 | NA |
| Non-expander Storage Backplane | Firmware DUP | 5DV1W | 7.16 | AX-650 | NA |
| NVMe Switch Storage Backplane | Firmware DUP | 5XJWN | 1.05 | AX-750 | NA |
| Expander Storage Backplane | Firmware DUP | H9PV3 | 1.2 | AX-7525 AX-750 | NA |
| Expander Storage Backplane | Firmware DUP | 60K1J | 2.52 | AX-640 AX-740xd | NA |
| Expander Storage Backplane | Firmware DUP | 2F90T | 2.46 | AX-6515 | NA |
| Chipset driver for 14G Intel platforms | Driver DUP | 4DDMJ | 10.1.19913.8607 | AX-640 AX-740xd | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| Chipset driver for 15G AMD platforms | Driver DUP | N28TF | 6.11.12.245 | AX-6515 AX-7525 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| Chipset driver for 15G Intel platforms | Driver DUP | C2MC3 | 10.1.19928.8615 | AX-650 AX-750 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| iDRAC Service Module | Firmware DUP | 258RC | 5.4.0.0 | AX-640 AX-740xd AX-6515 AX-7525 AX-650 AX-750 | NA |
| CPLD | Firmware DUP | 9N4DH | 1.0.6 | AX-640 | NA |
| CPLD | Firmware DUP | G65GH | 1.1.4 | AX-740xd | NA |
| CPLD | Firmware DUP | 79XGF | 1.0.7 | AX-6515 | NA |
| CPLD | Firmware DUP | 4NMC7 | 1.2.0 | AX-7525 | NA |
| CPLD | Firmware DUP | FCTDF | 1.1.1 | AX-650 AX-750 | NA |
Network Adapters
| Component | Part Number | SDDC Advanced Qualification | RDMA Protocol | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported OS | Supported Platforms |
|---|---|---|---|---|---|---|---|---|---|
| Broadcom 5720 Dual Port 1GbE On-Board LOM | JDN4V | Management | NA | 5V215 | 23.31.1 | JDV91 | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 | AX-650 |
| Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card | KJMHJ | Management | N/A | 5V215 | 23.31.1 | JDV91 | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 | AX-6515 |
| Broadcom 5720 Dual Port 1GbE On-Board LOM | 6V45N | Management | NA | 5V215 | 23.31.1 | JDV91 | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 | AX-750 |
| Broadcom 5720 Dual Port 1GbE On-Board LOM | 74H08 | Management | NA | 5V215 | 23.31.1 | JDV91 | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Azure Stack HCI-24H2 | AX-7525 |
| Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH | J3D14 | Management Compute (Premium) Storage (Premium) | RoCEv2 | HVN2R | 23.31.18.10 | T5K6M | 233.1.181.0 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4520c |
| Broadcom 57412 2 Port 10Gb SRP+ + 5720 2 Port 1 GB Base-T, rNDC | NWMNX | Management Compute (Standard) | Not Supported | HVN2R | 23.31.18.10 | T5K6M | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-640 AX-740xd |
| Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz, V3 | 24FG6 | Management Compute (Standard) | Not Supported | HVN2R | 23.31.18.10 | T5K6M | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 |
| Broadcom 57416 Dual Port 10 GbE SFP+ Network LOM Mezz Card | 6XH9X | ||||||||
| Broadcom 57414 Dual Port 25 Gb E SFP+ Network LOM Mezz Card | 930PP | ||||||||
| Broadcom 57416 Dual Port 10 GbE BaseT Network LOM Mezz Card | J4RN3 | ||||||||
| Broadcom BCM57414 25G SFP Dual Port OCP3 Mezz | NHN45 | ||||||||
| Broadcom 57416 Dual Port 10 Gb E SFP+ Network LOM Mezz Card | WC9TR | ||||||||
| Broadcom 57412 Dual Port 10GbE SFP+, OCP NIC 3.0 | CP610 | Management Compute (Standard) | Not Supported | HVN2R | 23.31.18.10 | T5K6M | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-7525 AX-650 AX-750 |
| Broadcom 57414 Dual Port 10/25GbE SFP28, OCP NIC 3.0 | KHCTP | ||||||||
| Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 | T6HR8 | ||||||||
| Broadcom 57504 Quad Port 10/25GbE,SFP28, OCP NIC 3.0 | X1KR4 | ||||||||
| Intel X710 DP 10Gb DA/SFP+ Ethernet, NDC | 6VDPG | Management Compute (Standard) | N/A | DC20J | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-7525 AX-640 AX-740xd |
| Intel X710-T4L Quad Port 10GbE BASE-T, OCP NIC 3.0 | 50RV4 | Management Compute (Standard) | N/A | DC20J | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-7525 AX-650 AX-750 |
| Intel(R) Ethernet 10G 4P X710-T4L-t Adapter | ND4PT | ||||||||
| Intel X710 Quad Port 10GbE SFP+, OCP NIC 3.0 | VF81P | ||||||||
| Intel X710-T2L Dual Port 10GbE BASE-T, OCP NIC 3.0 | VMFKR | ||||||||
| Intel X710 Dual Port 10GbE SFP+, OCP NIC 3.0 | YJYK1 | ||||||||
| Intel E823 | KJMHJ | Management Compute (Premium) Storage (Premium) | iWARP,RoCEv2 | N11TD | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4510c AX-4520c |
| Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP | 6J1N1 | Management Compute (Premium) Storage (Premium) | iWARP,RoCEv2 | N11TD | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-7525 AX-650 AX-750 |
| Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH | 85F8F | ||||||||
| Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH | CD16M | ||||||||
| Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP | DWNRF | ||||||||
| Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP | F6FXM | Management Compute (Premium) Storage (Premium) | RoCEv2 | 2CMVW | 22.41.10.00 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 AX-7525 AX-650 AX-750 |
| Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH | 8P2T2 | Management Compute (Premium) Storage (Premium) | RoCEv2 | 2CMVW | 22.41.10.00 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-7525 AX-650 AX-750 |
| Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, LP | 20NJD | Management Compute (Premium) Storage (Premium) | RoCEv2 | XGP2X | 14.32.20.04 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-640 AX-740xd |
| Mellanox ConnectX-4 Lx Dual Port 25GbE DA/SFP rNDC | R887V | Management Compute (Premium) Storage (Premium) | RoCEv2 | XGP2X | 14.32.20.04 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-640 R640 Storage Spaces Direct RN |
| Mellanox ConnextX-4 Lx Dual Port 25Gbe DA/SFP Network Adapter, FH | MRT0D | Management Compute (Premium) Storage (Premium) | RoCEv2 | XGP2X | 14.32.20.04 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-740xd |
| Mellanox ConnectX-4 LX Dual Port 10/25GbE SFP28 Adapter, FH, V2 | YGRX3 | ||||||||
| Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, FH | 71C1T | Management Compute (Premium) Storage (Premium) | RoCEv2 | XY16R | 16.35.30.06 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750 |
| Mellanox Connectx-5 EX Dual Port 100GbE QSFP20 PCIe Adapter, LP | 9FTMY | ||||||||
| Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe FH, V2 | F7V1F | ||||||||
| Mellanox ConnectX-5 Dual Port 10/25GbE SFP28 Adapter, PCIe LP, V2 | JGWVY | ||||||||
| Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, FH | TDNNT | ||||||||
| Mellanox ConnectX-5 Dual Port 25GbE SFP28 Adapter, LP | V5DG9 | ||||||||
| NVIDIA ConnectX-6LX Dual Port 25G GbE SFP28 | DN78C | Management Compute (Premium) Storage (Premium) | RoCEv2 | 1H4PM | 26.41.10.00 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-650 AX-750 AX-7525 |
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP | 6XJXK | Management Compute (Premium) Storage (Premium) | RoCEv2 | 1H4PM | 26.41.10.00 | G6M58 | 24.04.03 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 AX-7525 AX-650 AX-750 |
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH | R5WK9 | ||||||||
| QLogic 57800 2x10Gb DA/SFP+ +2x1Gb BT NDC | 165T0 | Management | N/A | 9KYR0 | 16.20.00 | VYWY1 | 36.20.02 | Windows Server 2022 Datacenter Azure Stack HCI-24H2 | AX-640 AX-740xd |
| QLogic 57800 2x10Gb BT + 2x1Gb BT NDC | G8RPD | ||||||||
| QLogic FastLinQ 41162 Dual Port 10GbE BASE-T and Dual Port 1GbE BASE-T, rNDC | 0D1WT | Management Compute (Premium) | iWARP | W93NY | 16.30.09 | RXJPP | 36.30.16 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-640 AX-740xd |
| QLogic FastLinQ 41164 Quad Port 10GbE BASE-T, rNDC | X1TD1 | Management Compute (Premium) | iWARP | W93NY | 16.30.09 | RXJPP | 36.30.16 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 AX-7525 AX-640 AX-740xd AX-650 AX-750 |
| QLogic FastLinQ 41164 Quad Port 10GbE SFP+, rNDC | XVVY1 | ||||||||
| QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, LP | 415DX | Management Compute (Premium) Storage (Premium) | iWARP | W93NY | 16.30.09 | RXJPP | 36.30.16 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-6515 AX-7525 AX-640 AX-740xd |
| QLogic FastLinQ 41262 Dual Port 25Gbe SFP28, rNDC | 4KF8J | ||||||||
| QLogic FastLinQ 41262 Dual Port 25Gb SFP28 Adapter, FH | 51GRM |
Network Switches
| Component | Category | Minimum Supported Version |
|---|---|---|
| Dell EMC Networking S4112F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4128F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4148F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5212F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5224F/S5248F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5232F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5448F-ON | Network Switch | 10.6.0.1.35 |
GPUs
| GPU Model | Vendor | Description | Part Number | Firmware version | Driver Version | GPU-P capable | Supported Platform | Supported OS |
|---|---|---|---|---|---|---|---|---|
| A10 | NVIDIA | NVIDIA Ampere A10, PCIe, 150W, 24GB,GPU, V2 | 6KNWW | 94.02.5C.00.04 | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A16 | NVIDIA | NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU | 8F04V | 94.07.54.00.45 | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A16 | NVIDIA | NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 | D1P1T | 94.07.54.00.45 | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A2 | NVIDIA | NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 | H98K0 | 94.07.5B.00.55 | 528.89 WHQL | Yes | AX-650 AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A2 | NVIDIA | NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 | MG5JX | 94.07.5B.00.55 | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A30 | NVIDIA | NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU | W3C1G | 92.00.58.00.01 | 528.89 WHQL | No | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A30 | NVIDIA | NVIDIA Ampere A30, PCIe, 165W, 24GB Passive, Double Wide, Full Height GPU, V2 | RV08M | 92.00.58.00.01 | 528.89 WHQL | No | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| A40 | NVIDIA | NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU | W6GX6 | 94.02.5C.00.0F | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| L4 | NVIDIA | NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU | V9XT2 | 95.04.29.00.06 | 528.89 WHQL | Yes | AX-650 AX-750 AX-7525 | Azure Stack HCI-24H2 |
| L4 | NVIDIA | NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU | NG3PY | 95.04.29.00.06 | 528.89 WHQL | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| L40 | NVIDIA | NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable | VHNWT | 95.02.39.00.01 | 553.62 | Yes | AX-750 AX-7525 | Azure Stack HCI-24H2 |
| T4 | NVIDIA | NVIDIA Tesla T4 16GB, PCIe, 70W, 16GB Passive, Single Wide, Full Height GPU | HCKJM | 90.04.96.00.01 | 528.89 WHQL | No | AX-750 | Azure Stack HCI-24H2 |
| T4 | NVIDIA | NVIDIA Tesla T4 16GB, PCIe, 70W, Passive, Single Wide, Low Profile GPU | 7PH29 | 90.04.96.00.01 | 528.89 WHQL | No | AX-750 | Azure Stack HCI-24H2 |
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.Storage Controllers
| Component | Dell Part Number | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|---|---|
| BOSS-S1 | 2MFVD | 3P39V | 2.5.13.3024 | 7004G | 1.2.0.1055 | AX-6515 AX-7525 AX-640 AX-740xd | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| BOSS-S2 | FGNRW | TTR5R | 2.5.13.4009 | 7004G | 1.2.0.1055 | AX-7525 AX-650 AX-750 | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| HBA330 Controller, 12Gps Mini Card | P2R3R | 124X2 | 16.17.01.00 | Inbox | 2.51.27.80 | AX-640 AX-740XD AX-6515 | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| HBA330 Controller, 12Gps Mini Card, LP | J7TNV | NKNVC | 16.17.01.00 | Inbox | 2.51.27.80 | AX-740xd | Windows Server 2022 Datacenter Azure Stack HCI-24H2 |
| HBA355i | K6MCJ | CG0P9 | 33.15.00.00 | R31NP | 2.61.74.00 | AX-7525 AX-650 AX-750 | Windows Server 2022 Datacenter Azure Stack HCI-23H2 |
| HBA355i | K6MCJ | CG0P9 | 33.15.00.00 | HDH8G | 2.61.74.00 | AX-7525 AX-650 AX-750 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
SATA M.2 SSD Boot Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SATA | M.2 | NA | Intel | S3520 | SSDSC2BB120G7R | 394XT | CHJGV | DL43 | 120 GB | Boot |
| SSD | SATA | M.2 | NA | Micron | 5100 | MTFDDAV240TCB | TC2RP | H6NHD | E013 | 240 GB | Boot |
| SSD | SATA | M.2 | NA | Micron | 5100 | MTFDDAV480TCB | GPGC0 | H6NHD | E013 | 480 GB | Boot |
| SSD | SATA | M.2 | NA | Micron | 5300 | MTFDDAV240TDU | T2GFX | KT63Y | J008 | 240 GB | Boot |
| SSD | SATA | M.2 | NA | Micron | 5300 | MTFDDAV480TDS | 7RKD7 | KT63Y | J008 | 480 GB | Boot |
| SSD | SATA | M.2 | Read Intensive | Intel | Youngsville RR S4520 | SSDSCKKB240GZR | CM88M | VJPKG | DL7C | 240 GB | Boot |
| SSD | SATA | M.2 | Read Intensive | Intel | Youngsville S4510 | SSDSCKKB240G8R | DMC15 | Y1P10 | DL6R | 240 GB | Boot |
| SSD | SATA | M.2 | Read Intensive | Micron | 5400 | MTFDDAV240TGC-1BC1ZABDA | T4MJ3 | RJ0WY | K003 | 240 GB | Boot |
SAS 2.5" HDD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HDD | SAS | 2.5 | NA | Seagate | Avenger | ST2000NX0463 | TMVN7 | GW3V7 | NT32 | 2 TB | Capacity |
| HDD | SAS | 2.5 | NA | Seagate | Skybolt | DL2400MM0159 | RWR8F | DRHV4 | ST5J | 2.4 TB | Capacity |
| HDD | SAS | 2.5 | NA | Seagate | Skybolt | ST2400MM0159 | 36YG1 | 7N5DH | ST7G | 2.4 TB | Capacity |
| HDD | SAS | 2.5 | NA | Toshiba | AL15SE | AL15SEB24EQY | F9NWJ | J11N2 | EF09 | 2.4 TB | Capacity |
| HDD | SAS | 2.5 | NA | Seagate | Skybolt ServoBP | BL2400MM0159 | 1D0F5 | 00P56 | SBSA | 2.4TB | Capacity |
SATA 2.5" HDD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HDD | SATA | 2.5 | NA | Seagate | Avenger | ST2000NX0423 | VR92X | GMW4P | NB33 | 2 TB | Capacity |
SATA 3.5" HDD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HDD | SATA | 3.5 | NA | HGST | Aries K Plus | HUS726020ALA610 | 8NP2N | KH52Y | KV46 | 2 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Aries K Plus | HUS726040ALA610 | 61FFW | KH52Y | KV46 | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Rainier MLK | HUS722T2TALA600 | V9H6C | V3DJM | MU03 | 2 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | Tomcat R | MG04ACA200NY | NPVM6 | 6D4CG | FK5D | 2 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | Tomcat R | MG04ACA400NY | 95M6K | 6D4CG | FK5D | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Nemo | ST2000NM0018-2F3130 | W8FW5 | CMK5N | EA04 | 2 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Makara BP | ST2000NM0145-2DC104 | WG9R0 | M5GJ1 | DB34 | 2 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Makara BP | ST4000NM0265-2DC107 | MWHY9 | M5GJ1 | DB34 | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Vela-A | HUS726T4TALA6L0 | YH3T9 | HV5HH | PV09 | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Vela-AP | HUS728T8TALE6L0 | 1WMVC | T0RX4 | RT09 | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Libra HE10 | HUH721008ALE600 | KRV2W | H12N2 | LT21 | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Makara Plus | ST8000NM0205-2FF112 | 92MDW | MR6RH | PB53 | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | MG06 | MG06ACA800EY | 9X09C | PT7D8 | GA09 | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | HGST | Leo-A He12 | HUH721212ALE600 | T2YHT | JCYF6 | NT11 | 12 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | MG07 | MG07ACA12TEY | 753F0 | 0942Y | GB03 | 12 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | MG08AC | MG08ACA16TEY | HPGJ4 | WTNDC | GC04 | 16 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | MG08AD | MG08ADA400NY | W2M9N | F73C5 | GD05 | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Cimarron | ST4000NM016A-2HZ130 | XPJ47 | RWK48 | CAJD | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Cimarron | ST8000NM012A-2KE131 | F4JXT | TF6TF | CALF | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Evans BP | ST12000NM002J-2TY133 | KTJTY | 4MPD6 | PALB | 12 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Evans BP | ST16000NM002J-2TW133 | JWV1P | 4MPD6 | PALB | 16 TB | Capacity |
| HDD | SATA | 3.5 | NA | Toshiba | MG08AD | MG08ADA800EY | T5XR5 | 65CDF | GE02 | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Cimarron BP | ST8000NM023B-2TJ133 | J7W80 | P183W | LA0C | 8 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Cimarron BP | ST4000NM018B-2TF130 | 6KR2M | T04YV | LC0A | 4 TB | Capacity |
| HDD | SATA | 3.5 | NA | Seagate | Cimarron BP | ST8000NM023B-2TJ133 | J7W80 | P183W | LA0C | 8 TB | Capacity |
SAS 3.5" HDD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HDD | SAS | 3.5 | NA | HGST | Aries K Plus | HUS726020ALS210 | VH6FW | 8W7XP | KU46 | 2 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Aries K Plus | HUS726040ALS210 | X4FKY | 8W7XP | KU46 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | Tomcat R | MG04SCA20ENY | HHX14 | RG9MK | EG03 | 2 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | Tomcat R | MG04SCA40ENY | 1MVTT | RG9MK | EG03 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Makara BP | ST2000NM0155 | 7RCGV | XKD4M | DT34 | 2 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Makara BP | ST4000NM0295 | 5JH5X | XKD4M | DT34 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Vela-A | HUS726T4TALS200 | NT1X2 | J5K8G | PU09 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Vela-AP | HUS728T8TAL5200 | 44YFV | 8GM6M | RS09 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Libra HE10 | HUH721008AL5200 | KRDKK | MGW91 | LS21 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Makara Plus | ST8000NM0185 | M40TH | 6421F | PT55 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG06 | MG06SCA800EY | FV725 | 4G5GY | EH0D | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Leo-A He12 | HUH721212AL5200 | 9HXK6 | 04PM5 | NS11 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Mobula BP | ST12000NM0158 | YMN53 | VTX9C | RSL5 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG07 | MG07SCA12TEY | DK7C9 | NFFHM | EI0D | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG07 | MG07SCA12TEY | KFJ7G | NFFHM | EI0D | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG09 | MG09SCA12TEY | 0N96X | 20Y02 | EM06 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SC | MG08SCA16TEY | 8MG73 | 9N3RR | EJ09 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SC | MG08SCA16TEY | 4N7V0 | 9N3RR | EJ09 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SC | MG08SCA16TEY | 24HF9 | 9N3RR | EJ09 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Evans | ST16000NM010G | CNXPV | 3YP54 | ESL9 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | WD | Paris-C | WUH721816AL5200 | VF206 | GY6MD | US09 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron | ST4000NM017A | KRM6X | J12RT | CSJA | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron | ST8000NM014A | 0N660 | 0HG6Y | CSLE | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron BP | ST4000NM019B | 10N7R | 3P5N0 | LW0B | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron BP | ST8000NM024B | C5HD0 | NM6GP | LS0C | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SD | MG08SDA400NY | FN2YX | GTG81 | EK06 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Evans BP | ST12000NM006J | M1C0T | XF65R | PSLG | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Evans BP | ST16000NM006J | 41DXR | XF65R | PSLG | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SD | MG08SDA800EY | NJWMG | F95CX | EL02 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron BP | ST8000NM024B | C5HD0 | NM6GP | LS0C | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | EvansBP | ST16000NM006J | 41DXR | XF65R | PSLG | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | LongsPeak | ST20000NM004D | R3G03 | WCTTD | GS09 | 20 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG10SD | MG10SDA800EY | VJDMM | 99TKP | EP02 | 8 TB | Capacity |
SATA 2.5" SSD Cache or Capacity
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SATA | 2.5 | Mixed Use | Intel | Youngsville-RR | SSDSC2KG019TZR | 8RXV5 | VJPKG | DL7C | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Toshiba | HK4 | THNSF8800CCSE | VCRY6 | H3XHN | DACB | 800 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Toshiba | HK4 | THNSF81D60CSE | DMF5Y | H3XHN | DACB | 1.6 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5300 | MTFDDAK960TDT | XMWMK | KT63Y | J008 | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5300 | MTFDDAK1T9TDT | MMCDY | KT63Y | J008 | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5400 | MTFDDAK3T8TGB-1BC1ZABDA | 34JK8 | JTW3W | K403 | 3.84 TB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | SM863a | MZ7KM960HMJP0D3 | DD4G0 | 97D8J | GD57 | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | SM863a | MZ7KM1T9HMJP0D3 | K5P0T | 97D8J | GD57 | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | SM883 | MZ7KH960HAJR0D3 | YDHYX | 3J3JR | HF58 | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | SM883 | MZ7KH1T9HAJR0D3 | 71K37 | 3J3JR | HF58 | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4600 | SSDSC2KG960G7R | TR3MY | V141M | DL5C | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4600 | SSDSC2KG019T7R | MWKF2 | V141M | DL5C | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4610 | SSDSC2KG960G8R | X31G3 | 4DW70 | DL6B | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4610 | SSDSC2KG019T8R | F8N2K | 4DW70 | DL6B | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4610 | SSDSC2KG019T8R | 55J8H | 4DW70 | DL6B | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5200 | MTFDDAK960TDN | HY1F8 | W2X8N | F005 | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5200 | MTFDDAK1T9TDN | XKF5Y | W2X8N | F005 | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Kioxia | HK6-V | KHK6YVSE960G | XW4D1 | W0YR1 | DBC4 | 960 GB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Kioxia | HK6-V | KHK6YVSE1T92 | 0DXJ7 | W0YR1 | DBC4 | 1.92 TB | Cache, Capacity |
| SSD | SATA | 2.5 | Mixed Use | Hynix | SE5130 | HFS960G3E2X149N | G162V | 4T2FN | DG00 | 960GB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Hynix | SE5130 | HFS1T9G3E2X149N | HCR09 | 4T2FN | DG00 | 1.92TB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | Youngsville-RR | SSDSC2KG960GZR | 8MHYH | VJPKG | DL7C | 960 GB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | Youngsville-RR | SSDSC2KG019TZR | 8RXV5 | VJPKG | DL7C | 1.92 TB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | Youngsville RR (New) (S4620) | SSDSC2KG960GZR | DYMD0 | VJPKG | DL7C | 960 GB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | Youngsville RR (New) (S4620) | SSDSC2KG019TZR | 6XW3M | VJPKG | DL7C | 1.92 TB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | PM897 | MZ7L3960HBLTAD3 | 96KT6 | VRG4Y | HH64 | 960 GB | Cache,Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | PM897 | MZ7L31T9HBNAAD3 | RRR7M | VRG4Y | HH64 | 1.92 TB | Cache,Capacity |
SATA 2.5" SSD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville-RR | SSDSC2KB960GZR | F6H8H | VJPKG | DL7C | 960 GB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville-RR | SSDSC2KB019TZR | VYYW8 | VJPKG | DL7C | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville-RR | SSDSC2KB038TZR | WNPN1 | VJPKG | DL7C | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville RR (New) (S4520) | SSDSC2KB960GZR | 5M8Y4 | VJPKG | DL7C | 960 GB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville RR (New) (S4520) | SSDSC2KB019TZR | 6J65H | VJPKG | DL7C | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville RR (New) (S4520) | SSDSC2KB038TZR | KM4C4 | VJPKG | DL7C | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5200 | MTFDDAK1T9TDD | VJ36D | W2X8N | F005 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5300 | MTFDDAK1T9TDS | GYGVV | KT63Y | J008 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5400 | MTFDDAK3T8TGA-1BC1ZABDA | CHF46 | JTW3W | K403 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5400 SED | MTFDDAK3T8TGA-1BC16ABDA | 2DXDK | JTW3W | K403 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Kioxia | HK6-R | KHK6YRSE1T92 | 919J7 | W0YR1 | DBC4 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Kioxia | HK6-R | KHK6YRSE3T84 | 8PYG5 | W0YR1 | DBC4 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883a | MZ7LH1T9HALT0D3 | 9F9Y6 | 3GHD6 | HG61 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883 | MZ7LH1T9HMLT0D3 | Y24T6 | 93P7P | HE59 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Hynix | SE5110 | HFS1T9G3H2X069N | 962FP | 7XTPF | DZ03 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Hynix | SE4011 | HFS1T9G32FEH-7A10A | 0XMV9 | 3DTV4 | DE08 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | S4510 | SSDSC2KB019T8R | 33R2T | 4DW70 | DL6B | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | S4500 | SSDSC2KB019T7R | XCN15 | V141M | DL5C | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | S4500 | SSDSC2KB038T7R | 3RRN8 | V141M | DL5C | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | S4510 | SSDSC2KB038T8R | 1RHK2 | 4DW70 | DL6B | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883 | MZ7LH3T8HMLT0D3 | FYP5F | 93P7P | HE59 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883a | MZ7LH3T8HALT0D3 | 5TVXD | 3GHD6 | HG61 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Hynix | SE4011 | HFS3T8G32FEH-7410A | D6C0R | 3DTV4 | DE08 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Hynix | SE5110 | HFS3T8G3H2X069N | 3GDK0 | 7XTPF | DZ03 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5300 | MTFDDAK3T8TDT | 4H1RX | R9YDC | J408 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville-RR | SSDSC2KB019TZR | VYYW8 | VJPKG | DL7C | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | Youngsville-RR | SSDSC2KB038TZR | WNPN1 | VJPKG | DL7C | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893 | MZ7L31T9HBLTAD3 | 0KYP4 | T3HX9 | HJ64 | 1.92 TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893 | MZ7L33T8HBLTAD3 | GCN5W | T3HX9 | HJ64 | 3.84 TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Hynix | SE5031 | HFS960G32FEH-BA10A | 7GR2K | 2CY65 | DD02 | 960 GB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Hynix | SE5031 | HFS1T9G32FEH-BA10A | GKTF1 | 2CY65 | DD02 | 1.92 TB | Capacity |
SAS 2.5" SSD Cache or Capacity
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1655 | MZILG800HCHQAD3 | 3CHC8 | 7MTXM | DWG9 | 800 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1655 | MZILG1T6HCJRAD3 | 5RJND | 7MTXM | DWG9 | 1.6 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | PM6 | KPM6XMUG800G | H6GCD | NGPR2 | BA48 | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | PM6 | KPM6XMUG1T60 | 5GDXH | NGPR2 | BA48 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG800G | JTKH5 | NGPR2 | BA48 | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG1T60 | GD3N0 | NGPR2 | BA48 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG3T20 | NKM7P | NGPR2 | BA48 | 3.2 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG6T40 | 6NW3J | NGPR2 | BA48 | 6.4 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | Phoenix M4 | PX05SMB080Y | CN3JH | 1DJXX | AS10 | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M4 | PX05SVB096Y | 503M7 | 1DJXX | AS10 | 960 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | Phoenix M4 | PX05SMB160Y | GVTYD | 1DJXX | AS10 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M4 | PX05SVB192Y | V0K7V | 1DJXX | AS10 | 1.92 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M4 | PX05SVB384Y | 3DDFT | 1DJXX | AS10 | 3.84 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | Phoenix M5-M | KPM5XMUG800G | DHRVV | CPP97 | B02A | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Write Intensive | Kioxia | Phoenix M5-M | KPM5XMUG1T60 | W9G88 | CPP97 | B02A | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1645a | MZILT800HBHQ0D3 | GW8T1 | VJY6V | DWA4 | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1645a | MZILT1T6HBJR0D3 | 3TCV6 | VJY6V | DWA4 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1645 | MZILT1T6HAJQ0D3 | DR0HX | 4PPHJ | DWF8 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | WD | Bear Cove Quantum | WUSTR6480BSS200 | 6VJC9 | 8W5WF | G138 | 800 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | WD | Bear Cove Quantum | WUSTR6416BSS200 | 6NF96 | 8W5WF | G138 | 1.6 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M5-V | KPM5XVUG960G | WFGTH | CPP97 | B02A | 960 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M5-V | KPM5XVUG1T92 | 2WVYG | CPP97 | B02A | 1.92 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | Phoenix M5-V | KPM5XVUG3T84 | 91W3V | CPP97 | B02A | 3.84 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 FIPS | KPM6WVUG960G | WMWKG | 6DH0W | BD48 | 960 GB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 FIPS | KPM6WVUG1T92 | DHWH5 | 6DH0W | BD48 | 1.92 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 FIPS | KPM6WVUG3T84 | 81H9C | 6DH0W | BD48 | 3.84 TB | Cache, Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 | KPM7XVUG800G | X96H8 | T21WT | C10E | 800 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 | KPM7XVUG1T60 | 4TRHM | T21WT | C10E | 1.6 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 (FIPS) | KPM7WVUG800G | 81G77 | 57MM2 | C40E | 800GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 (FIPS) | KPM7WVUG1T60 | G4NY4 | 57MM2 | C40E | 1.6TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 (FIPS) | KPM7WVUG3T20 | RGP9J | 57MM2 | C40E | 3.2TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 (FIPS) | KPM7WVUG3T84 | FMP6K | 57MM2 | C40E | 3.84TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6WVUG960G | J92FY | 6DH0W | BD48 | 960 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6WVUG1T92 | 1081V | 6DH0W | BD48 | 1.92 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6WVUG3T84 | MD4YN | 6DH0W | BD48 | 3.84 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG800G | NNGV4 | NGPR2 | BA48 | 800 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG1T60 | CHJJJ | NGPR2 | BA48 | 1.6 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | WD | Bear Cove Plus | WUSTR6416ASS200 | 8W6HC | 7HYHH | K968 | 1.6 TB | Cache,Capacity |
SAS 2.5" SSD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SAS | 2.5 | Read Intensive | WD | Bear Cove Plus | WUSTR1519ASS200 | 5ND33 | 7HYHH | K968 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | WD | Bear Cove Plus | WUSTR1538ASS200 | YW17N | 7HYHH | K968 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | WD | Bear Cove Quantum | WUSTVA119BSS200 | 02X38 | 8W5WF | G138 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | WD | Bear Cove Quantum | WUSTVA138BSS200 | FP1KF | 8W5WF | G138 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643 | MZILT1T9HAJQ0D3 | F0VFY | J3RRK | DSF8 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643 | MZILT3T8HALS0D3 | X8F87 | J3RRK | DSF8 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643 | MZILT7T6HMLA0D3 | RVYD5 | J3RRK | DSF8 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643a | MZILT1T9HBJR0D3 | TMTW9 | D7RNT | DSA4 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643a | MZILT3T8HBLS0D3 | CRNPH | D7RNT | DSA4 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1633a | MZILS1T9HEJH0D3 | 086DD | XNGNT | DSLA | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1633a | MZILS3T8HMLH0D3 | JR1HP | XNGNT | DSLA | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643a | MZILT960HBHQ0D3 | K74WN | D7RNT | DSA4 | 960 GB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1643a | MZILT7T6HALA0D3 | 84C40 | D7RNT | DSA4 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG1T9HCJRAD3 | NRR34 | 3MV58 | DSG9 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG3T8HCLSAD3 | 9N32F | 3MV58 | DSG9 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG7T6HBLAAD3 | Y8H7M | 3MV58 | DSG9 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG1T92 | 4CN85 | NGPR2 | BA48 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG3T84 | H9TT5 | NGPR2 | BA48 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG7T68 | PD02Y | NGPR2 | BA48 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 FIPS | KPM6WRUG1T92 | 7F2D1 | 6DH0W | BD48 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 FIPS | KPM6WRUG3T84 | FH1W9 | 6DH0W | BD48 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6WRUG1T92 | H1P07 | 6DH0W | BD48 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6WRUG3T84 | 3VHY3 | 6DH0W | BD48 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6WRUG7T68 | 5T78C | 6DH0W | BD48 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG1T92 | VRTN9 | NGPR2 | BA48 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG3T84 | 2XVX2 | NGPR2 | BA48 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM6 | KPM6XRUG7T68 | YM0T1 | NGPR2 | BA48 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 (FIPS) | KPM7WRUG1T92 | VGMCD | 57MM2 | C40E | 1.92TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 (FIPS) | KPM7WRUG3T84 | YTVTF | 57MM2 | C40E | 3.84TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 (FIPS) | KPM7WRUG7T68 | HCTYM | 57MM2 | C40E | 7.68TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | Phoenix M5-R | KPM5XRUG1T92 | TDNP7 | CPP97 | B02A | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | Phoenix M5-R | KPM5XRUG3T84 | N85XX | CPP97 | B02A | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | Phoenix M4 | PX05SRB384Y | XCRDV | 1DJXX | AS10 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Seagate | LangeBP | XS3840SE70114 | KXDCD | NKGWD | 3D03 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Seagate | LangeBP | XS1920SE70114 | D4VFW | NKGWD | 3D03 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG1T92 | 6K35K | T21WT | C10E | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG3T84 | MT0R5 | T21WT | C10E | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG7T68 | 7N1WT | T21WT | C10E | 7.68 TB | Capacity |
Value SAS 2.5" SSD
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | VSAS | 2.5 | Read Intensive | Seagate | LangeBP SED | XS1920SE70134 | K9T53 | G04C8 | 4S0C | 1.92 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Seagate | LangeBP SED | XS3840SE70134 | 4KPKF | G04C8 | 4S0C | 3.84 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Seagate | LangeBP SED | XS7680SE70134 | 2THYF | G04C8 | 4S0C | 7.68 TB | Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Kioxia | Phoenix RM5 | KRM5XVUG3T84 | X78JM | NDG7N | B710 | 3.84 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | LangeBP ISE | XS3840LE70154 | NWGX3 | NX13G | 4D0C | 3.84 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | Cooper (Nytro 2550) | XS960LE70095 | 2M1NG | RRWVT | CPE9 | 960GB | Cache,Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | Cooper (Nytro 2550) | XS1920LE70095 | K805Y | RRWVT | CPE9 | 1.92TB | Cache,Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | Cooper (Nytro 2550) | XS3840LE70095 | FT95M | RRWVT | CPE9 | 3.84TB | Cache,Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | Phoenix RM5 | KRM5XRUG7T68 | 5XD2F | NDG7N | B710 | 7.68 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Seagate | Lange ISE | XS7680SE70074 | 2PKRH | H3VHX | EC16 | 7.68 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Seagate | LangeBP ISE | XS7680SE70154 | 5KW0F | NX13G | 4D0C | 7.68 TB | Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | LangeBP SED | XS960LE70134 | 2RDWT | G04C8 | 4S0C | 960 GB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | LangeBP SED | XS1920LE70134 | N6DRV | G04C8 | 4S0C | 1.92 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Seagate | LangeBP SED | XS3840LE70134 | YM9HP | G04C8 | 4S0C | 3.84 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Kioxia | RM6 | KRM6VVUG960G | 42XXC | 5WMK8 | BJ07 | 960 GB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Kioxia | RM6 | KRM6VVUG1T92 | N15JP | 5WMK8 | BJ07 | 1.92 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Mixed Use | Kioxia | RM6 | KRM6VVUG3T84 | FXYGR | 5WMK8 | BJ07 | 3.84 TB | Cache, Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM6 | KRM6VRUG1T92 | 1FGWG | 5WMK8 | BJ07 | 1.92 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM6 | KRM6VRUG3T84 | XNXD2 | 5WMK8 | BJ07 | 3.84 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM6 | KRM6VRUG7T68 | 5MHY8 | 5WMK8 | BJ07 | 7.68 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM7 | KRM7VVUG960G | 05MT7 | 1YD58 | CA0C | 960 GB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM7 | KRM7VVUG1T92 | 59XF2 | 1YD58 | CA0C | 1.92 TB | Capacity |
| SSD | VSAS | 2.5 | Read Intensive | Kioxia | RM7 | KRM7VVUG3T84 | M0JVN | 1YD58 | CA0C | 3.84 TB | Capacity |
| SSD | vSAS | 2.5 | Read Intensive | Kioxia | RM7 | KRM7VRUG7T68 | D480G | 1YD58 | CA0C | 7.68 TB | Capacity |
| SSD | vSAS | 2.5 | Read Intensive | Seagate | Cooper | XS7680SE70145 | 1J46N | RRWVT | CPE9 | 7.68 TB | Capacity |
NVMe 2.5" Cache or Capacity
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | 2.5 | Write Intensive | Intel | Optane P4800x SSD/NVMe, 375GB U.2 2.5" SFF | SSDPE21K375GAT | 3DM57 | HMRK7 | E201DP38 | 375 GB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 1.6TB 2.5" SFF | MZWLL1T6HEHP-000D3 | JD6CH | 34C36 | 1.2.1 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 3.2TB 2.5" SFF | MZWLL3T2HMJP-000D3 | JDMHM | 34C36 | 1.2.1 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 6.4TB 2.5" SFF | MZWLL6T4HMLS-000D3 | Y3XT2 | 34C36 | 1.2.1 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 1.6TB 2.5" SFF | MZWLL1T6HAJQ-000D3 | 4WDXY | NC07Y | 1.2.2 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 3.2TB 2.5" SFF | MZWLL3T2HAJQ-000D3 | K60N7 | NC07Y | 1.2.2 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 6.4TB 2.5" SFF | MZWLL6T4HMLA-000D3 | 08NMX | NC07Y | 1.2.2 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P4600, Dell Express Flash NVMe 1.6TB 2.5" SFF | SSDPE2KE016T7T | F5P84 | CR0HC | QDV1DP17 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P4600, Dell Express Flash NVMe 3.2TB 2.5" SFF | SSDPE2KE032T7T | MCV6J | CR0HC | QDV1DP17 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P4610, Dell Express Flash NVMe 1.6TB 2.5" SFF | SSDPE2KE016T8T | 58V30 | GD4X4 | VDV1DP25 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P4610, Dell Express Flash NVMe 3.2TB 2.5" SFF | SSDPE2KE032T8T | 2CN1T | GD4X4 | VDV1DP25 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P4610, Dell Express Flash NVMe 6.4TB 2.5" SFF | SSDPE2KE064T8T | X27HY | GD4X4 | VDV1DP25 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | KIOXIA | DELL EXPRESS FLASH KIOXIA CM6 MU 1.6TB U.2 FIPS | KCM6FVUL1T60 | G7N00 | WJD95 | 3.1.7 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE | MZWLJ1T6HBJRAD3 | 6GK00 | 5CM3G | 2.5.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | NA | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE | MZWLJ3T2HBJRAD3 | 15TVC | 5CM3G | 2.5.0 | 3.2TB | Cache,Capacity |
| NVMe | PCIe | NA | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE | MZWLJ6T4HALAAD3 | F6V5P | 5CM3G | 2.5.0 | 6.4TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL1T60 | P03YC | GMM6V | 2.2.2 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL3T20 | 97GR0 | GMM6V | 2.2.2 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL6T40 | K916X | GMM6V | 2.2.2 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P5600 SP 3WPD | D7 P5600 Series 1.6TB | C9X5T | CGXH7 | 1.2.4 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | P5600 SP 3WPD | D7 P5600 Series 3.2TB | PRKTM | CGXH7 | 1.2.4 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | Arbordale Plus RR P5620 | SSDPF2KE016T1E | 82TVJ | 12W9R | 1.5.0 | 1.6 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | Arbordale Plus RR P5620 | SSDPF2KE032T1E | TY3M5 | 12W9R | 1.5.0 | 3.2 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Intel | Arbordale Plus RR P5620 | SSDPF2KE064T1E | 5WCR8 | 12W9R | 1.5.0 | 6.4TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 V2 SP 3WPD | MZWLR1T6HBJRAD3 | 0MNMV | 5V3P7 | 2.5.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 V2 SP 3WPD | MZWLR3T2HBLSAD3 | V69W3 | 5V3P7 | 2.5.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 V2 SP 3WPD | MZWLR6T4HALAAD3 | H8D5M | 5V3P7 | 2.5.0 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR1T6HCJRAD3 | H8GHV | 71KRG | 1.2.0 | 1.6 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR3T2HCLSAD3 | 617H6 | 71KRG | 1.2.0 | 3.2 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR6T4HBLAAD3 | 9F6Y3 | 71KRG | 1.2.0 | 6.4 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG1T60 | MP4F2 | K1JTM | 2.0.3 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG3T20 | XFNX0 | K1JTM | 2.0.3 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG6T40 | 8RJJ9 | K1JTM | 2.0.3 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS1T6GEJVX171N | 1HYKD | 9M65G | 1.2.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS3T2GEJVX171N | 9VWPD | 9M65G | 1.2.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS6T4GEJVX171N | PYMY6 | 9M65G | 1.2.0 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO1T6HCJR-00AD3 | FVC2P | V7V0K | 1.0.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO3T2HCLS-00AD3 | FDNHD | V7V0K | 1.0.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO6T4HBLA-00AD3 | 64K9C | V7V0K | 1.0.0 | 6.4 TB | Cache, Capacity |
NVMe 2.5" Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | 2.5 | Read Intensive | Toshiba | CD5 | KCD5XLUG960G | DRC9H | T79D5 | 1.2.0 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Toshiba | CD5 | KCD5XLUG3T84 | 17C57 | T79D5 | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | P4510 | SSDPE2KX040T8T | 5GMK0 | GD4X4 | VDV1DP25 | 4 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | KIOXIA | DELL EXPRESS FLASH KIOXIA CM6 RI 1.92TB U.2 FIPS | KCM6FRUL1T92 | TXP72 | WJD95 | 3.1.7 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | P5500 | SSDPF2KX019T9T | WPP9G | CGXH7 | 1.2.4 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | P5500 | SSDPF2KX038T9T | KRT3G | CGXH7 | 1.2.4 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | P5500 | SSDPF2KX076T9T | RNN67 | CGXH7 | 1.2.4 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR3T8HBLSAD3 | G5N65 | 5V3P7 | 2.5.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR7T6HALAAD3 | DX74Y | 5V3P7 | 2.5.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR15THALAAD3 | 182NW | 5V3P7 | 2.5.0 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR1T9HCJRAD3 | 8PMRM | 71KRG | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR3T8HCLSAD3 | RJKM5 | 71KRG | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR7T6HBLAAD3 | R1J8J | 71KRG | 1.2.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR15THBLAAD3 | D4CJG | 71KRG | 1.2.0 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL1T92 | N0VK0 | GMM6V | 2.2.2 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL3T84 | 8W2G5 | GMM6V | 2.2.2 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL7T68 | VD0JX | GMM6V | 2.2.2 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL15T3 | J91CR | GMM6V | 2.2.2 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | Arbordale Plus RR P5520 | SSDPF2KX019T1E | 0HVC7 | 12W9R | 1.5.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | Arbordale Plus RR P5520 | SSDPF2KX038T1E | 77MRY | 12W9R | 1.5.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | Arbordale Plus RR P5520 | SSDPF2KX076T1E | 90M2J | 12W9R | 1.5.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | Arbordale Plus R P5316 | SSDPF2NV307TZ | 4KCVT | 4XT8T | 1.6.0 | 30.72 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG1T92 | M8YW0 | K1JTM | 2.0.3 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG3T84 | XHYGF | K1JTM | 2.0.3 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG7T68 | VV2M7 | K1JTM | 2.0.3 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG15T3 | DX2PD | K1JTM | 2.0.3 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD7 | KCD7XRUG7T68 | 0RD61 | K6597 | 2.0.1 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG1T92 | NNKCT | HV8P1 | 2.0.1 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG3T84 | N1MK1 | HV8P1 | 2.0.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG7T68 | MXD8J | HV8P1 | 2.0.1 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS1T9GEJVX171N | 7GGK1 | 9M65G | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS3T8GEJVX171N | J4TDK | 9M65G | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS7T6GEJVX171N | 2533N | 9M65G | 1.2.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS15T3EJVX171N | 8TY8G | 9M65G | 1.2.0 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PE8110 | HFS7T6GEETX099N | RG3T2 | TDGKY | 1.1.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO3T8HCLS-00AD3 | 9GXVF | V7V0K | 1.0.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO7T6HBLA-00AD3 | DNPR4 | V7V0K | 1.0.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL6960HFJA-00AD3 | 71Y2J | X5N7N | 1.0.1 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZVL61T9HBL1-00AD3 | NYPRM | FTVJG | 1.0.1 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL63T8HFLT-00AD3 | 2H60T | X5N7N | 1.0.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL67T6HBLC-00AD3 | VYT6X | X5N7N | 1.0.1 | 7.68 TB | Capacity |
NVMe Add-in Cards
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 1.6TB HHHL AIC | MZPLL1T6HEHP-000D3 | 06V6M | 34C36 | 1.2.1 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 3.2TB HHHL AIC | MZPLL3T2HMLS-00003 | C2KKH | 34C36 | 1.2.1 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725A, Dell Express Flash NVMe 6.4TB HHHL AIC | MZPLL6T4HMLS-000D3 | 604N5 | 34C36 | 1.2.1 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 1.6TB (MU) HHHL AIC | MZPLL1T6HAJQ-000D3 | FTX2R | NC07Y | 1.2.2 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 3.2TB (MU) HHHL AIC | MZPLL3T2HAJQ-00005 | 73KJ7 | NC07Y | 1.2.2 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1725b, Dell Express Flash NVMe 6.4TB (MU) HHHL AIC | MZPLL6T4HMLA-000D3 | FW2K0 | NC07Y | 1.2.2 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE | MZPLJ1T6HBJRAD3 | Y7D7D | 5CM3G | 2.5.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | AIC | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, NVMe, HHHL, 512e, ISE | MZPLJ6T4HALAAD3 | 91FXC | 5CM3G | 2.5.0 | 6.4 TB | Cache, Capacity |
2 - Azure Local Support Matrix for 16G (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Supported Platforms
| Model | Supported Operating System |
|---|---|
| AX-760 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| AX-660 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| MC-660 | Azure Stack HCI-24H2 |
| MC-760 | Azure Stack HCI-24H2 |
Base Components
| Component | Type | Software Bundle | Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|
| BIOS | Firmware DUP | GPMNW | 2.8.2 | AX-660 AX-760 MC-660 MC-760 | NA |
| Chipset driver for 16G Intel platforms | Driver DUP | R40PW | 10.1.19928.8615 | AX-660 AX-760 MC-660 MC-760 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| iDRAC9 with Lifecycle Controller | Firmware DUP | KYWDC | 7.20.80.50 | AX-660 AX-760 MC-660 MC-760 | NA |
| Expander Storage Backplane | Firmware DUP | J9JW2 | 1.61 | AX-760 MC-760 | NA |
| NVMe Switch Storage Backplane | Firmware DUP | R39FM | 3.33 | AX-760 MC-760 | NA |
| Non-expander Storage Backplane | Firmware DUP | 58MWX | 7.2 | AX-760 MC-760 | NA |
| Non-expander Storage Backplane | Firmware DUP | 9T7YG | 7.2 | AX-660 MC-660 | NA |
| iDRAC Service Module | Firmware DUP | 258RC | 5.4.0.0 | AX-660 AX-760 MC-660 MC-760 | NA |
| CPLD | Firmware DUP | XJG0V | 1.2.7 | AX-660 AX-760 MC-660 MC-760 | NA |
Network Adapters
| Component | Part Number | SDDC Advanced Qualification | RDMA Protocol | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported OS | Supported Platforms |
|---|---|---|---|---|---|---|---|---|---|
| Broadcom 5720 Dual Port 1 GbE Network LOM Mezz Card | 5NN70 | Management | N/A | 5V215 | 23.31.1 | JDV91 | 233.1.181.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-660 AX-760 MC-660 MC-760 |
| Broadcom 57504 Quad Port 10/25GbE, SFP28 Adapter | 3Y64D | Management Compute (Premium) Storage (Premium) | RoCEv2 | HVN2R | 23.31.18.10 | T5K6M | 233.1.181.0 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-660 AX-760 MC-660 MC-760 |
| Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH | J3D14 | ||||||||
| Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe LP | 6J1N1 | Management Compute (Premium) Storage (Premium) | iWARP,RoCEv2 | N11TD | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-660 AX-760 MC-660 MC-760 |
| Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH | 85F8F | ||||||||
| Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH | CD16M | ||||||||
| Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe LP | DWNRF | ||||||||
| Intel E810-XXVDA2 Dual Port 1/10/25GbE SFP28 Adapter | PWH3C | ||||||||
| Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter, PCIe FH | VK88G | ||||||||
| Intel E810-XXVDA4 Quad Port 1/10/25GbE SFP28 Adapter | Y4VV5 | ||||||||
| Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH | 8P2T2 | Management Compute (Premium) Storage (Premium) | RoCEv2 | 2CMVW | 22.41.10.00 | G6M58 | 24.4.26429 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-660 AX-760 MC-660 MC-760 |
| Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, LP | F6FXM | ||||||||
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe LP | 6XJXK | Management Compute (Premium) Storage (Premium) | RoCEv2 | 1H4PM | 26.41.10.00 | G6M58 | 24.4.26429 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-660 AX-760 MC-660 MC-760 |
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter | DN78C | ||||||||
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH | R5WK9 | Management Compute (Premium) Storage (Premium) | RoCEv2 | 1H4PM | 26.41.10.00 | G6M58 | 24.4.26429 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-760 MC-760 |
Network Switches
| Component | Category | Minimum Supported Version |
|---|---|---|
| Dell EMC Networking S4112F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4128F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4148F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5212F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5224F/S5248F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5232F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5448F-ON | Network Switch | 10.6.0.1.35 |
GPUs
| GPU Model | Vendor | Description | Part Number | Firmware version | Driver Version | GPU-P capable | Supported Platform | Supported OS |
|---|---|---|---|---|---|---|---|---|
| A16 | NVIDIA | NVIDIA Ampere A16, PCIe, 250W, 64GB Passive, Double Wide, Full Height GPU,V2 | D1P1T | 94.07.54.00.45 | 553.62 | Yes | AX-760 MC-760 | Azure Stack HCI-24H2 |
| A2 | NVIDIA | NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Low Profile GPU, V2 | H98K0 | 94.07.5B.00.55 | 553.62 | Yes | AX-660 AX-760 MC-660 MC-760 | Azure Stack HCI-24H2 |
| A2 | NVIDIA | NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 | MG5JX | 94.07.5B.00.55 | 553.62 | Yes | AX-660 AX-760 MC-660 MC-760 | Azure Stack HCI-24H2 |
| A40 | NVIDIA | NVIDIA Ampere A40, PCIe, 300W, 48GB Passive, Double Wide, Full Height GPU | W6GX6 | 94.02.5C.00.0F | 553.62 | Yes | AX-760 MC-760 | Azure Stack HCI-24H2 |
| L4 | NVIDIA | NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU | NG3PY | 95.04.29.00.06 | 553.62 | Yes | AX-660 AX-760 MC-660 MC-760 | Azure Stack HCI-24H2 |
| L4 | NVIDIA | NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Low Profile GPU | V9XT2 | 95.04.29.00.06 | 553.62 | Yes | AX-660 AX-760 MC-660 MC-760 | Azure Stack HCI-24H2 |
| L40 | NVIDIA | NVIDIA Ampere L40, PCIe, 300W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable | VHNWT | 95.02.39.00.01 | 553.62 | Yes | AX-760 MC-760 | Azure Stack HCI-24H2 |
| L40S | NVIDIA | NVIDIA Ampere L40S, PCIe, 350W, 48GB Passive, Double Wide, Full Height, Full Length, GPU with cable | 7WK28 | 95.02.66.00.02 | 553.62 | Yes | AX-760 MC-760 | Azure Stack HCI-24H2 |
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.Storage Controllers
| Component | Dell Part Number | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|---|---|
| BOSS-N1 | WW56V | C6MVR | 2.1.13.2037 | Inbox | Inbox | AX-660 AX-760 MC-660 MC760 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| HBA355i | K6MCJ | CG0P9 | 33.15.00.00 | HDH8G | 2.61.74.00 | AX-660 AX-760 MC-660 MC760 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| HBA355i | K6MCJ | CG0P9 | 33.15.00.00 | R31NP | 2.61.74.00 | AX-660 AX-760 MC-660 MC760 | Windows Server 2022 Datacenter |
SATA M.2 SSD Boot Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7400 | MTFDKBA960TDZ | PRV6C | N71F4 | 1.6.0 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7400 | MTFDKBG960TDZ | 0V8F7 | N71F4 | 1.6.0 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE8010 | HFS960GDC8X099N | 21GXV | R2TTT | 1.3.0 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE9010 | HFS960GEJ8X167N | 4H05X | YJG7C | 1.3.1 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7450 | MTFDKBAXXXTFR | PH7J6 | JHKXR | 1.4.0 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE9010 | HFS960GDJ8X167N | XN5KG | 8X8YR | 1.2.1 | 960GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Samsung | PM9D3a | MZVL6480HFLUAD3 | C82V9 | FTVJG | 1.0.1 | 480 GB | Boot |
| NVMe | PCIe | M.2 | Read Intensive | Samsung | PM9D3a | MZVL6960HFLBAD3 | 8M3JN | FTVJG | 1.0.1 | 960 GB | Boot |
SAS 3.5" HDD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HDD | SAS | 3.5 | NA | HGST | Vela-A | HUS726T4TALS200 | NT1X2 | J5K8G | PU09 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG10 | MG10SDA400NY | 9VN79 | 99TKP | EP02 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Vela-AP | HUS728T8TAL5200 | 44YFV | 8GM6M | RS09 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG06 | MG06SCA800EY | FV725 | 4G5GY | EH0D | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | HGST | Leo-A He12 | HUH721212AL5200 | 9HXK6 | 04PM5 | NS11 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | WD | Paris-C | WUH721816AL5200 | VF206 | GY6MD | US09 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron BP | ST4000NM019B | 10N7R | 3P5N0 | LW0B | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Cimarron BP | ST8000NM024B | C5HD0 | NM6GP | LS0C | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SD | MG08SDA400NY | FN2YX | GTG81 | EK06 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Evans BP | ST12000NM006J | M1C0T | XF65R | PSLG | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Evans BP | ST16000NM006J | 41DXR | XF65R | PSLG | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG08SD | MG08SDA800EY | NJWMG | F95CX | EL02 | 8 TB | Capacity |
| HDD | SAS | 3.5 | Read Intensive | Seagate | LongsPeak | ST20000NM004D | R3G03 | WCTTD | GS09 | 20 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG10SD | MG10SDA800EY | VJDMM | 99TKP | EP02 | 8 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | CimarronBP(EWP) | DL4000NM019B | F7DTR | M7PKX | LBW4 | 4 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG09 | MG09SCA12TEY | 0N96X | 20Y02 | EM06 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Summit | ST12000NM007H | FN7VR | 3VY0D | SWS9 | 12 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG09 | MG09SCA16TEY | MXC46 | 20Y02 | EM06 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Summit | ST16000NM007H | R0G8W | C50CR | SYS9 | 16 TB | Capacity |
| HDD | SAS | 3.5 | NA | Toshiba | MG10 | MG10SCA20TEY | NT45N | 0H3CX | EN04 | 20 TB | Capacity |
| HDD | SAS | 3.5 | NA | WD | Paris-D PR2 | WUH722020BL5200 | 1D4CR | XRFX3 | VS19 | 20 TB | Capacity |
| HDD | SAS | 3.5 | NA | Seagate | Summit | ST20000NM007H | R5KP7 | C50CR | SYS9 | 20 TB | Capacity |
| HDD | SAS | 3.5 | NA | WD | London DP | WUH722420AL5200 | MTTCF | FN2N1 | YS01 | 20 TB | Capacity |
SATA 2.5" SSD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SATA | 2.5 | Read Intensive | Intel | S4520 | SSDSC2KB019TZR | 6J65H | VJPKG | DL7C | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | SK Hynix | SE5110 | HFS1T9G3H2X069N | 962FP | 7XTPF | DZ03 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883a | MZ7LH1T9HALT0D3 | 9F9Y6 | 3GHD6 | HG61 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893 | MZ7L31T9HBLTAD3 | 0KYP4 | T3HX9 | HJ64 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893a | MZ7L31T9HELAAD3 | PTD53 | D5D3W | HL58 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5300 | MTFDDAK1T9TDS | GYGVV | KT63Y | J008 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5400 | MTFDDAK1T9TGA-1BC1ZABDA | KXNX5 | RJ0WY | K003 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Intel | S4520 | SSDSC2KB038TZR | KM4C4 | VJPKG | DL7C | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | SK Hynix | SE5110 | HFS3T8G3H2X069N | 3GDK0 | 7XTPF | DZ03 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM883a | MZ7LH3T8HALT0D3 | 5TVXD | 3GHD6 | HG61 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893 | MZ7L33T8HBLTAD3 | GCN5W | T3HX9 | HJ64 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Samsung | PM893a | MZ7L33T8HELAAD3 | D7V89 | D5D3W | HL58 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5300 | MTFDDAK3T8TDT | 4H1RX | R9YDC | J408 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Read Intensive | Micron | 5400 | MTFDDAK3T8TGA-1BC1ZABDA | CHF46 | JTW3W | K403 | 3.84TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Intel | S4620 | SSDSC2KG019TZR | 6XW3M | VJPKG | DL7C | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | SK Hynix | SE5130 | HFS1T9G3E2X149N | HCR09 | 4T2FN | DG00 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | SK Hynix | SE5031 | HFS1T9G32FEH-BA10A | GKTF1 | 2CY65 | DD02 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | PM897a | MZ7L31T9HENAAD3 | GR4WN | V5XNY | HK58 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Samsung | PM897 | MZ7L31T9HBNAAD3 | RRR7M | VRG4Y | HH64 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5300 | MTFDDAK1T9TDT | MMCDY | KT63Y | J008 | 1.92TB | Capacity |
| SSD | SATA | 2.5 | Mixed Use | Micron | 5400 | MTFDDAK1T9TGB-1BC1ZABDA | XRXX2 | RJ0WY | K003 | 1.92TB | Capacity |
SAS 2.5" SSD Cache or Capacity
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1655 | MZILG800HCHQAD3 | 3CHC8 | 7MTXM | DWG9 | 800 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Samsung | PM1655 | MZILG1T6HCJRAD3 | 5RJND | 7MTXM | DWG9 | 1.6 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 | KPM7XVUG1T60 | 4TRHM | T21WT | C10E | 1.6 TB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM6 | KPM6XVUG800G | NNGV4 | NGPR2 | BA48 | 800 GB | Cache,Capacity |
| SSD | SAS | 2.5 | Mixed Use | Kioxia | PM7 | KPM7XVUG800G | X96H8 | T21WT | C10E | 800 GB | Cache,Capacity |
SAS 2.5" SSD Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG1T9HCJRAD3 | NRR34 | 3MV58 | DSG9 | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG3T8HCLSAD3 | 9N32F | 3MV58 | DSG9 | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Samsung | PM1653 | MZILG7T6HBLAAD3 | Y8H7M | 3MV58 | DSG9 | 7.68 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG1T92 | 6K35K | T21WT | C10E | 1.92 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG3T84 | MT0R5 | T21WT | C10E | 3.84 TB | Capacity |
| SSD | SAS | 2.5 | Read Intensive | Kioxia | PM7 | KPM7XRUG7T68 | 7N1WT | T21WT | C10E | 7.68 TB | Capacity |
NVMe 2.5" Cache or Capacity
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, NVMe, 2.5, 512e, ISE | MZWLJ1T6HBJRAD3 | 6GK00 | 5CM3G | 2.5.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE | MZWLJ3T2HBJRAD3 | 15TVC | 5CM3G | 2.5.0 | 3.2TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 SP 3WPD, SSD, Gen4 NVMe, 2.5, 512e, ISE | MZWLJ6T4HALAAD3 | F6V5P | 5CM3G | 2.5.0 | 6.4TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL1T60 | P03YC | GMM6V | 2.2.2 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL3T20 | 97GR0 | GMM6V | 2.2.2 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM6 SP | KCM6XVUL6T40 | K916X | GMM6V | 2.2.2 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 V2 SP 3WPD | MZWLR3T2HBLSAD3 | V69W3 | 5V3P7 | 2.5.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735 V2 SP 3WPD | MZWLR6T4HALAAD3 | H8D5M | 5V3P7 | 2.5.0 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR1T6HCJRAD3 | H8GHV | 71KRG | 1.2.0 | 1.6 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR3T2HCLSAD3 | 617H6 | 71KRG | 1.2.0 | 3.2 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1735a | MZWLR6T4HBLAAD3 | 9F6Y3 | 71KRG | 1.2.0 | 6.4 TB | Cache,Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG1T60 | MP4F2 | K1JTM | 2.0.3 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG3T20 | XFNX0 | K1JTM | 2.0.3 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XVUG6T40 | 8RJJ9 | K1JTM | 2.0.3 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS1T6GEJVX171N | 1HYKD | 9M65G | 1.2.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS3T2GEJVX171N | 9VWPD | 9M65G | 1.2.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Hynix | PS1030 | HFS6T4GEJVX171N | PYMY6 | 9M65G | 1.2.0 | 6.4 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO1T6HCJR-00AD3 | FVC2P | V7V0K | 1.0.0 | 1.6 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO3T2HCLS-00AD3 | FDNHD | V7V0K | 1.0.0 | 3.2 TB | Cache, Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Samsung | PM1745 | MZWLO6T4HBLA-00AD3 | 64K9C | V7V0K | 1.0.0 | 6.4 TB | Cache, Capacity |
NVMe 2.5" Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR3T8HBLSAD3 | G5N65 | 5V3P7 | 2.5.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR7T6HALAAD3 | DX74Y | 5V3P7 | 2.5.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR1T9HCJRAD3 | 8PMRM | 71KRG | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR3T8HCLSAD3 | RJKM5 | 71KRG | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR7T6HBLAAD3 | R1J8J | 71KRG | 1.2.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR15THBLAAD3 | D4CJG | 71KRG | 1.2.0 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL1T92 | N0VK0 | GMM6V | 2.2.2 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL3T84 | 8W2G5 | GMM6V | 2.2.2 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL7T68 | VD0JX | GMM6V | 2.2.2 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CM6 | KCM6XRUL15T3 | J91CR | GMM6V | 2.2.2 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG1T92 | M8YW0 | K1JTM | 2.0.3 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG3T84 | XHYGF | K1JTM | 2.0.3 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG7T68 | VV2M7 | K1JTM | 2.0.3 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Mixed Use | Kioxia | CM7 | KCM7XRUG15T3 | DX2PD | K1JTM | 2.0.3 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD7 | KCD7XRUG7T68 | 0RD61 | K6597 | 2.0.1 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG3T84 | N1MK1 | HV8P1 | 2.0.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS1T9GEJVX171N | 7GGK1 | 9M65G | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS3T8GEJVX171N | J4TDK | 9M65G | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS7T6GEJVX171N | 2533N | 9M65G | 1.2.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PS1010 | HFS15T3EJVX171N | 8TY8G | 9M65G | 1.2.0 | 15.36 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PE8010 | HFS960GECTX088N | WR2FG | T1XKD | 1.3.0 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PE8110 | HFS7T6GEETX099N | RG3T2 | TDGKY | 1.1.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG960G | YNGYD | HV8P1 | 2.0.1 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7450 | MTFDKCC960TFR | KXT48 | TVCWT | 1.4.0 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7500 | MTFDKCC960TGP | G7NCH | 5F07C | 1.2.0 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9A3 | MZQL2960HCJRAD3 | 6HYWM | XMFKX | 1.1.1 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733a | MZWLR1T9HCJRAD3 | 8PMRM | 71KRG | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1733 V2 | MZWLR1T9HBJRAD3 | WPR17 | 5V3P7 | 2.5.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9A3 | MZQL21T9H | TGYF5 | XMFKX | 1.1.1 | 1.92TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7450 | MTFDKCC1T9TFR | JH61J | TVCWT | 1.4.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7500 | MTFDKCC1T9TGP | M7RHM | 5F07C | 1.2.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PE8110 | HFS1T9GEETX099N | 147DR | TDGKY | 1.1.0 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7450 | MTFDKCC3T8TFR | NDK2D | TVCWT | 1.4.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD7 | KCD7XRUG3T84 | RFYP9 | K6597 | 2.0.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Hynix | PE8010 | HFS3T8GECTX088N | V6WP5 | T1XKD | 1.3.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9A3 | MZQL23T8HCLSAD3 | P7G03 | XMFKX | 1.1.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7500 | MTFDKCC3T8TGP | GT3F3 | 5F07C | 1.2.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Intel | Arbordale Plus R P5316 | SSDPF2NV307TZ | 4KCVT | 4XT8T | 1.6.0 | 30.72 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO3T8HCLS-00AD3 | 9GXVF | V7V0K | 1.0.0 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO7T6HBLA-00AD3 | DNPR4 | V7V0K | 1.0.0 | 7.68 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG1T92 | NNKCT | HV8P1 | 2.0.1 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9A3 | MZQL27T6HBLAAD3 | 30FX3 | XMFKX | 1.1.1 | 7.68TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7450 | MTFDKCC7T6TFR | 91KYJ | TVCWT | 1.4.0 | 7.68TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Micron | 7500 | MTFDKCC7T6TGP | RTJFW | 5F07C | 1.2.0 | 7.68TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Kioxia | CD8 | KCD8XRUG7T68 | MXD8J | HV8P1 | 2.0.1 | 7.68TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | SK Hynix | PE8110 | HFS960GEETX099N | 26WJ0 | TDGKY | 1.1.0 | 960GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO1T9HCJR-00AD3 | G64N5 | V7V0K | 1.0.0 | 1.92TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | SK Hynix | PE8110 | HFS3T8GEETX099N | 2V97V | TDGKY | 1.1.0 | 3.84TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM1743 | MZWLO15THBLA-00AD3 | VPWMR | V7V0K | 1.0.0 | 15.36TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL6960HFJA-00AD3 | 71Y2J | X5N7N | 1.0.1 | 960 GB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZVL61T9HBL1-00AD3 | NYPRM | FTVJG | 1.0.1 | 1.92 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL63T8HFLT-00AD3 | 2H60T | X5N7N | 1.0.1 | 3.84 TB | Capacity |
| NVMe | PCIe | 2.5 | Read Intensive | Samsung | PM9D3a | MZWL67T6HBLC-00AD3 | VYT6X | X5N7N | 1.0.1 | 7.68 TB | Capacity |
3 - Azure Local Support Matrix for 45n0c (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
Supported Platforms
| Model | Supported Operating System |
|---|---|
| AX-4510c | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| AX-4520c | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| MC-4510c | Azure Stack HCI-24H2 |
| MC-4520c | Azure Stack HCI-24H2 |
Base Components
| Component | Type | Software Bundle | Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|
| BIOS | Firmware DUP | FP79X | 1.21.1 | AX-4510c AX-4520c MC-4510c MC-4520c | NA |
| iDRAC9 with Lifecycle Controller | Firmware DUP | KYWDC | 7.20.80.50 | AX-4510c AX-4520c MC-4510c MC-4520c | NA |
| Chipset driver for 15G Intel platforms | Driver DUP | C2MC3 | 10.1.19928.8615 | AX-4510c AX-4520c MC-4510c MC-4520c | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
| iDRAC Service Module | Firmware DUP | 258RC | 5.4.0.0 | AX-4510c AX-4520c MC-4510c MC-4520c | NA |
| Chassis Manager | Firmware DUP | WC84H | 5 | AX-4510c AX-4520c MC-4510c MC-4520c | NA |
| CPLD | Firmware DUP | G1YRC | 1.0.5 | AX-4510c AX-4520c MC-4510c MC-4520c | NA |
Network Adapters
| Component | Part Number | SDDC Advanced Qualification | RDMA Protocol | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported OS | Supported Platforms |
|---|---|---|---|---|---|---|---|---|---|
| Broadcom 57504 Quad Port 10/25GbE SFP28 Adapter, PCIe FH | J3D14 | Management Compute (Premium) Storage (Premium) | RoCEv2 | HVN2R | 23.31.18.10 | T5K6M | 1.10.3 | Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4520c MC-4520c |
| Intel E823 | KJMHJ | Management Compute (Premium) Storage (Premium) | iWARP,RoCEv2 | N11TD | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4510c AX-4520c MC-4510c MC-4520c |
| Intel E810-CQDA2 Dual Port 100GbE QSFP28 Adapter, PCIe FH | 85F8F | Management Compute (Premium) Storage (Premium) | iWARP,RoCEv2 | N11TD | 24.0.5 | PH5GK | 24.0.0 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4520c MC-4520c |
| Intel E810-XXV Dual Port 25GbE SFP28 Adapter, PCIe FH | CD16M | ||||||||
| Mellanox ConnectX-6 Dx Dual Port 100GbE QSFP56 PCIe Adapter, FH | 8P2T2 | Management Compute (Premium) Storage (Premium) | RoCEv2 | 2CMVW | 22.41.10.00 | G6M58 | 24.4.26429 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4520c MC-4520c |
| Nvidia ConnectX-6 Lx Dual Port 10/25GbE SFP28 Adapter, PCIe FH | R5WK9 | Management Compute (Premium) Storage (Premium) | RoCEv2 | 1H4PM | 26.41.10.00 | G6M58 | 24.4.26429 | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 | AX-4520c MC-4520c |
Network Switches
| Component | Category | Minimum Supported Version |
|---|---|---|
| Dell EMC Networking S4112F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4128F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S4148F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5212F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5224F/S5248F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5232F-ON | Network Switch | 10.6.0.1.35 |
| Dell EMC Networking S5448F-ON | Network Switch | 10.6.0.1.35 |
GPUs
| GPU Model | Vendor | Description | Part Number | Firmware version | Driver Version | GPU-P capable | Supported Platform | Supported OS |
|---|---|---|---|---|---|---|---|---|
| A2 | NVIDIA | NVIDIA Ampere A2, PCIe, 60W, 16GB Passive, Single Wide, Full Height GPU, V2 | MG5JX | 94.07.5B.00.55 | 528.89 WHQL | Yes | AX-4520c MC-4520c | Azure Stack HCI-24H2 |
| L4 | NVIDIA | NVIDIA L4, PCIe, 72W, 24GB Passive, Single Wide Full Height GPU | NG3PY | 95.04.29.00.06 | 528.89 WHQL | Yes | AX-4520c MC-4520c | Azure Stack HCI-24H2 |
NOTE
Dell update packages are not available for GPU cards, please download the latest driver version from NVIDIA driver download page.Storage Controllers
| Component | Dell Part Number | Firmware Software Bundle | Firmware Minimum Supported Version | Driver Software Bundle | Driver Minimum Supported Version | Supported Platforms | Supported OS |
|---|---|---|---|---|---|---|---|
| BOSS-N1 | M88HH | 67GHR | 2.1.13.2037 | Inbox | AX-4510c AX-4520c MC-4510c MC-4520c | Windows Server 2022 Datacenter Windows Server 2025 Datacenter Azure Stack HCI-24H2 |
NVMe 2.5" Capacity Only
| Type | Drive Type | Form Factor | Endurance | Vendor | Series | Model | Device Part Number (P/N) | Firmware Software Bundle | Firmware Minimum Supported Version | Capacity | Use |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7400 | MTFDKBG1T9TDZ | G18YX | N71F4 | 1.6.0 | 1.92TB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7400 | MTFDKBG3T8TDZ | 2RN2N | N71F4 | 1.6.0 | 3.84TB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE8010 | HFS960GDC8X099N | 21GXV | R2TTT | 1.3.0 | 960GB | Capacity |
| NVMe | PCIe | M.2 | Mixed Use | Hynix | PE8030 | HFS800GDC8X088N | 31XDY | R2TTT | 1.3.0 | 800GB | Capacity |
| NVMe | PCIe | M.2 | Mixed Use | Micron | 7450 | MTFDKBA800TFS | F9MKX | JHKXR | 1.4.0 | 800GB | Capacity |
| NVMe | PCIe | M.2 | Mixed Use | Hynix | PE9030 | HFS800GDJ8X167N | FYWN9 | 9GH86 | 1.2.1 | 800GB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE9010 | HFS960GDJ8X167N | XN5KG | 8X8YR | 1.2.1 | 960GB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE9010 | HFS960GEJ8X167N | 4H05X | YJG7C | 1.3.1 | 960GB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7450 | MTFDKBA960TFR | PH7J6 | JHKXR | 1.4.0 | 960GB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7450 | MTFDKBG1T9TFR | J927V | JHKXR | 1.4.0 | 1.92TB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE8110 | HFS1T9GDE0X088N | MY5M4 | 19H08 | 1.1.0 | 1.92TB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Micron | 7450 | MTFDKBG3T8TFR | 5FP33 | JHKXR | 1.4.0 | 3.84TB | Capacity |
| NVMe | PCIe | M.2 | Read Intensive | Hynix | PE8110 | HFS3T8GDE0X088N | 5JR5H | 19H08 | 1.1.0 | 3.84TB | Capacity |
4 - Azure Local Golden Images (Dell 2512)
NOTE
SBE package 4.2.2512.xxxx and newer will only support Azure Local solution versions 12.*.1001.* or 12.*.1002.* (HCI OS 24H2) and newer.
Dell will support the use of SBE package 4.2.2509.xxxx on Azure Local instances running version 11.* (HCI OS 23H2) until April 2026. Dell recommends that instances running version 11.* be upgraded to 12.* as soon as possible to remain in a supported state.
The Dell Technologies provided operating system golden image for Azure Local instances is for imaging AX servers prior to deploying an Azure Local instance. This image is based on the Azure Stack HCI OS, with Microsoft customization and Dell Technologies customization. This image includes drivers provided by Dell Technologies.
Azure Local Golden Images for Solution versions 12.2510.1002.* - 12.2604.1002.* with Dell SBE 4.2.2512.*
5 - Azure Local Dell Solution Builder Extensions Release Notes (Dell 2512)
Overview
Solution Builder Extensions (SBE) for Azure Local. Firmware, Driver, and WDAC Supplemental policy for lifecycle management for Azure Local instances running on Dell AX servers.
| SBE Release Version | Download links | Supported Servers | Driver and Firmware versions | HCI OS Version | Supported Solution Version |
|---|---|---|---|---|---|
| 4.2.2512.1616 | https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=52Y76 | AX-660 AX-760 AX-4510C AX-4520C APEX MC-660 APEX MC-760 APEX MC-4510C APEX MC-4520C |
Azure Local Support Matrix for 16G (2512) | Solutions for Microsoft Azure Azure Local Support Matrix for AX-4500 (2512) | Solutions for Microsoft Azure |
24H2 | 12.*.1002.* 12.*.1001.* |
| 4.2.2512.1514 | https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=DTD2M | AX-650 AX-750 AX-6515 AX-7525 |
Azure Local Support Matrix for 14G-15G (2512) | Solutions for Microsoft Azure | 24H2 | 12.*.1002.* 12.*.1001.* |
| 4.2.2512.1403 | https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=VJ48M | AX-640 AX-740xd |
Azure Local Support Matrix for 14G-15G (2512) | Solutions for Microsoft Azure | 24H2 | 12.*.1002.* 12.*.1001.* |
Important Caveats
-
NVIDIA ConnectX NIC resets have been observed by customers under certain workloads. Affected driver version
25.1.26647.0and corresponding firmware was introduced in the SBE4.2.2506.n. SBE4.2.2509.nand4.2.2512.nwill downgrade the NVIDIA ConnectX driver to version24.4.26429.0, but the ConnectX firmware must be manually downgraded prior to installing SBE4.2.2512.n. For details and instructions, see KB000376360. -
Dell Micron 7450 and 7500 NVMe SSDs occasionally enter a panic state. For details and instructions, see KB000368482. From the SBE table above, find the version relevant to your product and install the SBE with updated firmware that resolves the defect for the Micron 7450 and 7500 drives.
-
SBE versions
4.2.2512.1616and4.2.2512.1514include the same BIOS version as previously released SBE versions4.2.2509.1625and4.1.2509.1516for the 16G, 45n0c, AX-650, and AX-750. New Azure Local instance deployments may have newer BIOS versions as listed in the Dell 2512 support matrix. The installation of SBE4.2.2512.nwill not downgrade the BIOS version in this case. The supported BIOS versions are listed in the Dell 2512 support matrix.
New for This Release
SBE 4.2.2512.1616
- Driver and Firmware 2512 Update
- Added server component health checks
- Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
- Added support for APEX MC branded nodes
- To install this SBE version, Azure Local instances that are already deployed must be running solution version
12.*.1001.*or12.*.1002.*
SBE 4.2.2512.1514
- Driver and Firmware 2512 Update
- Added server component health checks
- Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
- To install this SBE version, Azure Local instances that are already deployed must be running solution version
12.*.1001.*or12.*.1002.*
SBE 4.2.2512.1403
- Driver and Firmware 2512 Update
- Added server component health checks
- Added checks for downloading the latest SBE discovery manifest during updates that use automated SBE download
- To install this SBE version, Azure Local instances that are already deployed must be running solution version
12.*.1001.*or12.*.1002.*
Prerequisites
Update Firmware and Drivers Prior to Azure Local Instance Deployment
Drivers and firmware need to be installed on the servers that will be the instance members prior to deployment from the Azure Portal or using an ARM Template. This requirement is independent of the installation of the SBE. The machines imaged with Dell provided golden image will include the required Dell provided Out-of-Box drivers, but the firmware versions must still be validated and possibly updated prior to the instance deployment. The most current driver and firmware versions listed in the support matrix are recommended.
The Azure Local support matrix for Dell AX servers can be found here, Support Matrix | Solutions for Microsoft Azure
iDRAC Access from Host OS
The iDRAC pass-through NIC must be enabled and have an IP address assigned to it. iDRAC pass-through NIC is enabled by default and has an APIPA (Automatic Private IP Addressing) IP address assigned. This IP address must be accessible by the iDRAC NIC Remote NDIS Compatible Device in the host operating system. This is a dedicated link to the host OS and cannot be accessed outside the host OS.
iDRAC access health checks are introduced starting with the December 2024 SBE releases. These health checks verify that the required iDRAC access has been implemented on each server that will be an instance member. The iDRAC access health checks run automatically as part of the standard built-in SBE health checks. These health checks must complete successfully for the SBE installation to proceed. Failure remediation instructions are provided in case the health check fails.
Manual iDRAC Access Verification
The following procedures provide a manual method for verifying the required iDRAC access. The iDRAC access health checks provide automated and more comprehensive verification method.
Example iDRAC Pass-through settings
The iDRAC NIC Remote NDIS Compatible Device in the host operating system is used by the SBE CAU plug-in to update firmware. This NIC must be enabled and have an IP address assigned to it. By default, this NIC is enabled and has an APIPA IP address assigned to it that can access the iDRAC pass-through IP address. DHCP client should not be disabled on this NIC.
This is a dedicated link to iDRAC from the host OS and cannot be accessed outside the host OS.
The IP address can be obtained using the following PowerShell command:
Get-NetAdapter -InterfaceDescription "Remote NDIS Compatible Device" | Get-NetIPAddress -AddressFamily IPv4 | Select-Object -Property IPAddress
Example:
IPAddress
---------
169.254.0.2
Azure Local instances using Non-Transparent, Unauthenticated Network Proxy
Azure Local instances using non-transparent, unauthenticated network proxy must have the iDRAC pass-through IP address in the network proxy exclusion list. For information on how to configure the non-transparent, unauthenticated network proxy see, Configure proxy settings for Azure Local
The following example shows how to configure the APIPA IP address range 169.254.0.0/16 to be in the network proxy exclusion list.
$NoProxy = "localhost,127.0.0.1,.svc,10.0.0.0/8,172.16.0.0/12,192.168.0.0/16,.contoso.com,node1,node2,ClusterName,169.254.0.0/16"
[Environment]::SetEnvironmentVariable("NO_PROXY", $NoProxy, "Machine")
Download Connector – Automated download of future SBE release
Overview
Download Connector is a component in the SBE (Solutions Builder Extensions) that automates the downloading of new SBE bundles as they become available for your cluster. Once an SBE that includes the Download Connector is installed on your cluster, manually downloading and importing follow-on SBE version is no longer required. The update service will automate the downloading of the next available SBE for your Azure Local instance in a similar manner to how the download of the solution upgrade is automated. The Download Connector is part of the SBE version 4.1.2505.1501 and newer.
SBE versions that include the Download Connector also include system and update health checks that proactively verify the ability of the Download Connector to access the required remote resource when it comes time to download the next SBE for your cluster. System health checks are run once per day and update health checks are run at the initial phase of the update process.
Firewall Requirements
The SBE Download Connector running in the Azure Local instance needs to periodically connect to the internet resources to download SBE bundles for your cluster. The following outbound connectivity is required.
| Endpoint Description | Endpoint URL | Port |
|---|---|---|
| SBE bundle download | dl.dell.com/* | 443 |
| SBE download catalog | downloads.dell.com/filestore/Prod/SbeDownloadCatalog/AX_SBE_Download_Catalog.xml | 443 |
| SBE download catalog redirection | aka.ms/DellAzureLocalSBEDownloadCatalog | 443 |
| Digicert Certificate Revocation Status | http://crl3.digicert.com/* | 80 |
| Digicert Certificate Revocation Status | http://crl4.digicert.com/* | 80 |
Installation
Download and Extract
CAUTION
Steps 3 and 4 must be completed to ensure that the latest SBE Discovery manifest is used.SBE bundle zip file has the naming convention Bundle_SBE_Dell_AS-HCI-AX-GenerationNumber_VersionNumber.zip.
-
Download the SBE bundle zip file for your Dell AX server generation using the download link above. The SBE bundles are specific to the AX 14G platforms, AX 15G platforms, and AX 16G platforms
-
Extract the three SBE files from the SBE bundle zip file. There are two xml files and one zip file. Example:
- SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.xml
- SBE_Dell_AS-HCI-AX-16G-45n0c_4.2.2506.1600.zip
- SBE_Discovery_Dell.xml
-
Navigate to https://aka.ms/AzureStackSBEUpdate/DellEMC and press
Ctrl + Sto download the SBE_Discovery_Dell.xml file -
Replace the SBE_Discovery_Dell.xml file that was in the SBE bundle zip with the file downloaded in step 3
There are two options for installing the SBE package. The SBE package can be installed as part of instance creation or imported after instance creation is successfully completed. The importing method is also used to update the SBE to a newer version when the currently running SBE does not include Download Connector capability.
Automated Download and Extraction
SBE release starting with 4.1.2505.1501 and newer include the Download Connector that automates downloading and extracting the SBE. Manual download and SBE bundle extraction are unnecessary when an SBE with this capability is already installed on the Azure Local instance.
Installing SBE as Part of Instance Creation
Starting with June 2025 Dell golden image release, the SBE files are included in the golden image and already placed in the C:\SBE directory. The following 3 steps do not need to be performed.
- On each server that will be an instance member, create the following directory:
C:\SBE - Copy the three SBE files to the directory
C:\SBEon each server that will be an instance member - Proceed to deploying the instance from the Azure Portal or an ARM template
Importing the SBE After Successful Azure Local Instance Creation
-
Create a directory on a cluster shared volume (CSV) for sideloading the SBE, e.g.,
C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600 -
Copy the three extracted SBE files to this directory
-
Load the SBE files by running the following command with the path to the directory that holds the three extracted SBE files
Add-SolutionUpdate -SourceFolder "C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c_4.2.2506.1600" -
Check the state of the SBE that was just added. The state needs to be
Ready.Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE" -
Verify that the Azure Local instance is in a healthy state and is ready for the SBE installation by running the following commands on one of the Azure Local instance machines:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate -PrepareOnly -
Wait for the health check to complete. The solution update state will report
HealthCheckingwhile the health check is in progress. -
After the health check completes, run the following command if the solution update state reports
HealthCheckFailed:$Result = (Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"}).HealthCheckResult $Result | Where-Object { ($_.Status -ne "SUCCESS" -and $_.Severity -eq "CRITICAL" ) } | Format-List -Property Title, Status, Severity, Description, Remediation, TargetResourceName, TargetResourceType
All tests with Critical severity must have the Success status before continuing to the next step.
-
Start the SBE installation by running the following command:
Get-SolutionUpdate | Where-Object { $_.State -imatch "Ready" -and $_.PackageType -eq "SBE" } | Start-SolutionUpdate -
The SBE installation progress can be checked by running the following command:
Get-SolutionUpdate | Where-Object -Property PackageType -EQ "SBE" | Format-List -Property ResourceID, Description, State, SBEVersion, UpdateStateProperties, HealthState
For more information see, Update Azure Local via PowerShell
Known Issues
SBE Installation May Fail With Driver CAU Plug-In Error When Attempting to Delete NVIDIA ConnectX Driver That Is Not Installed
Description
The failure occurs in the driver CAU plug-in when driver downgrade option is specified for a given driver and the driver is not found in the driver store. This failure occurs in the following conditions:
- Cluster nodes were not imaged using Dell provided Azure Local golden image
- NVIDIA ConnectX NIC is not installed in the cluster nodes
- A previous version of an AX SBE is not installed
Workaround
Run the following script on each instance machine after completing step 5 “Verify that the Azure Local instance is in a healthy state and is ready for the SBE installation” in the Importing the SBE After Successful Azure Local Instance Creation section or when the failure is encountered during the SBE installation.
#Run this script on each node in the cluster.
$ConnectXDriverFileName = "mlx5.inf"
$InstalledConnectXDriver = Get-WindowsDriver -Online | Where-Object -Property OriginalFileName -IMatch $ConnectXDriverFileName
if (-not $InstalledConnectXDriver) {
Write-Output "Out-of-Box NVIDIA ConnectX driver not found on node: $($env:COMPUTERNAME)"
Write-Output "Checking SBE installation status on cluster: $((Get-Cluster).Name)"
$SBEWithPackagePaths = Get-SolutionUpdate | Where-Object { ($_.PackageType -eq "SBE") -and ($_.PackagePath -ne $null) -and ($_.PackagePath -notlike "https*") }
if ($SBEWithPackagePaths) {
$SBEPackagePath = ($SBEWithPackagePaths | Select-Object -First 1).PackagePath
$MlxDriverInfBaseFilePath = Join-Path -Path $SBEPackagePath -ChildPath "DriversGE\Network\Mellanox"
$MlxDriverInfFilePath = Get-ChildItem -Path $MlxDriverInfBaseFilePath -Filter $ConnectXDriverFileName -Recurse
Write-Output "SBE payload NVIDIA ConnectX driver file path: $($MlxDriverInfFilePath.FullName)"
if (Test-Path -Path $MlxDriverInfFilePath.FullName) {
Write-Output "Importing NVIDIA ConnectX driver..."
pnputil.exe /add-driver $MlxDriverInfFilePath.FullName /install
if (Get-WindowsDriver -Online | Where-Object -Property OriginalFileName -IMatch $ConnectXDriverFileName) {
Write-Output "NVIDIA ConnectX driver has been added to the driver store"
} else {
Write-Output "NVIDIA ConnectX driver is still not found in the driver store on node: $($env:COMPUTERNAME)"
}
} else {
Write-Output "Failed to resolve path: $($MlxDriverInfFilePath.FullName)"
}
} else {
Write-Output "SBE package path not found"
}
} else {
Write-Output "Found NVIDIA ConnectX driver version: $($InstalledConnectXDriver.Version) in the driver store"
Write-Output "No further action is required on this node"
}
Background
This SBE installation failure is resolved in the Azure Local Solution version 12.2512.1002.* and newer.
The driver CAU plug-in driver downgrade option is used in special cases. Currently, it is only used in the case of NVIDIA ConnectX NIC driver.
Partially Installed SBE Version 4.0.0.0 When SBE Is Installed as Part of Cluster Deployment
Description
Get-SolutionUpdateEnvironment reports partially installed SBE when installing the SBE as part of Azure Local instance deployment. SBE version 4.0.0.0 indicates a partially installed Solution Builder Extension (SBE).
Get-SolutionUpdateEnvironment
ResourceId : redmond
SbeFamily : AX-16G-45n0c
HardwareModel : AX-760
LastChecked : 08/01/2026 14:09:31
PackageVersions : {Solution: 12.2512.1002.16, Services: 10.2512.0.9, Platform: 12.2512.0.3021, SBE: 4.0.0.0}
CurrentVersion : 12.2512.1002.16
CurrentSbeVersion : 4.0.0.0
LastUpdated :
State : UpdateAvailable
HealthState : Success
HealthCheckResult : {Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage Services Physical Disks Summary...}
HealthCheckDate : 07/01/2026 17:50:07
AdditionalData : {[SBEAdditionalData, Solution Builder extension is partially installed. Please install the latest Solution Builder Extension provided by your hardware vendor. For more information, see https://aka.ms/SBE.]}
Workaround
Reinstall the same SBE version using the SBE import method or automated download method after Azure Local instance deployment successfully completes.
Background
The SBE driver CAU plug-in expects all drivers and firmware in the SBE payload to be installed on the server during or prior to deployment. However, some of the drivers in the SBE payload may not apply to the server model or components in the server model. Microsoft is aware of this limitation and is working to resolve this issue in a future release.
The partially installed SBE issue, can also occur if a component firmware version installed on the server is different than what is in the SBE payload. The SBE cannot update firmware or drivers during Azure Local instance deployment.
SBE installation will not downgrade drivers that have a newer version than the same driver in the SBE payload
Dell supports the driver and firmware versions listed here, Support Matrix | Solutions for Microsoft Azure
Description
The SBE driver CAU plug-in will not attempt to downgrade installed drivers that are higher version than the ones in its payload unless otherwise specified by Dell.
AMD DRTM (Dynamic Root of Trust for Measurement) Driver Fails to Update on AX AMD Platforms When the DRTM Device Was Originally Enabled at Azure Local Instance Deployment Time and Later Disabled
Description
SBE installation fails because the driver CAU plug-in in the SBE is unable to update the AMD DRTM driver to a newer version that is in the SBE payload. The AMD DRTM driver is one of the AMD Chipset drivers in the SBE package. The AMD DRTM driver update fails because the AMD DRTM setting was originally enabled but later disabled.
Workaround
Verify that the AMD DRTM BIOS setting is on. Turn back on the AMD DRTM setting if it is off.
The DRTM option is in the BIOS configuration: System Security -> TPM Advanced Settings -> AMD DRTM
Make sure to suspend and drain the Azure Local cluster node prior to rebooting the node. Make sure that BitLocker protection is disabled for the boot volume on the cluster node before making BIOS configuration changes. Disable BitLocker if it is enabled for the boot volume C:\ prior to rebooting the server for the BIOS changes to take effect. Reenable BitLocker for the boot drive after the server successfully reboots.
Background