BIOS and iDRAC configuration recommendations
BIOS Configuration
The following table lists the BIOS configuration settings for server nodes implemented as Storage Spaces Direct cluster nodes.
BIOS Section | BIOS Token | PE Default Value | AX Value | Platform |
---|---|---|---|---|
Processor Settings | Virtualization Technology | Enabled | Enabled | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Processor Settings | x2APIC Mode | Enabled | Enabled | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Processor Settings | NUMA Nodes Per Socket | 1 | 4 | AX-6515 AX-7525 |
Integrated Devices | SR-IOV Global Enable | Disabled | Enabled | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
System Profile Settings | Systems Profile | Performance Per Watt (DAPC) | Performance | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Systems Security | TPM Security | Off | On | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Systems Security | AC Power Recovery | NA | On | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Systems Security | AC Power Recovery Delay | NA | Random | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Systems Security | Secure Boot | Disabled | Enabled | AX-640 AX-740xd AX-650 AX-750 AX-6515 AX-7525 |
Processor Settings | Kernel DMA Protection | Disabled | Enabled | AX-650 AX-750 AX-7525 |
Processor Settings | Secure Memory Encryption | Disabled | Enabled | AX-7525 |
Processor Settings | Transparent Secure Memory Encryption | Disabled | Enabled | AX-7525 |
Systems Security | TPM PPI Bypass Provision | Disabled | Enabled | AX-650 AX-750 AX-7525 |
Systems Security | TPM PPI Bypass Clear | Disabled | Enabled | AX-650 AX-750 AX-7525 |
Systems Security | TPM2 Algorithm Selection | SHA1 | SHA256 | AX-650 AX-750 AX-7525 |
Systems Security | Intel TXT/AMD DRTM | Off | On | AX-650 AX-750 AX-7525 |
Systems Security | SMM Security Mitigation | Disabled | Enabled | AX-7525 |
iDRAC Configuration
The following table lists the iDRAC settings for server nodes configured as Azure Stack HCI cluster nodes.
Setting Category | Setting Name | Desired Value |
---|---|---|
Network Settings | Enable NIC | Enable |
NIC Selection | Dedicated | |
IPMI Settings | Enable IPMI Over LAN* | Enable |
Power Configuration | Redundancy Policy | Input Power Redundant |
Enable Hot Spare | Enabled | |
Primary Power Supply Unit | PSU1 |
*Required only if you plan to use SCVMM based management of bare-metal server.
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.