powerflex_sds (Data Source)
This data-source can be used to fetch information related to Storage Data Servers from a PowerFlex array.
Note: Exactly one of
protection_domain_name
andprotection_domain_id
is required.
Note: Only one of
sds_names
andsds_ids
can be provided at a time.
Example Usage
# commands to run this tf file : terraform init && terraform apply --auto-approve
# To read SDS, either protection_domain_name or protection_domain_id must be provided
# This datasource reads a specific SDS either by sds_names or sds_ids where user can provide a list of sds ids or names
# if both sds_names and sds_ids are not provided , then it will read all the sds under the protection domain
# Both sds_ids and sds_names can't be provided together .
# Both protection_domain_name and protection_domain_id can't be provided together
data "powerflex_sds" "example2" {
# require field is either of protection_domain_name or protection_domain_id
protection_domain_name = "domain1"
# protection_domain_id = "202a046600000000"
sds_names = ["SDS_01_MOD", "sds_1", "node4"]
# sds_ids = ["6adfec1000000000", "6ae14ba900000006", "6ad58bd200000002"]
}
output "allsdcresult" {
value = data.powerflex_sds.example2
}
Schema
Optional
protection_domain_id
(String) Protection Domain ID. Conflicts withprotection_domain_name
.protection_domain_name
(String) Protection Domain Name. Conflicts withprotection_domain_id
.sds_ids
(List of String) List of SDS IDs. Conflicts withsds_names
.sds_names
(List of String) List of SDS names. Conflicts withsds_ids
.
Read-Only
id
(String) Placeholder identifier attribute.sds_details
(Attributes List) List of fetched SDS. (see below for nested schema)
Nested Schema for sds_details
Read-Only:
authentication_error
(String) Authentication error.certificate_info
(Attributes) Certificate Information. (see below for nested schema)configured_drl_mode
(String) Configured DRL mode.drl_mode
(String) DRL mode.faultset_id
(String) Fault set ID.fgl_metadata_cache_size
(Number) FGL metadata cache size.fgl_metadata_cache_state
(String) FGL metadata cache state.fgl_num_concurrent_writes
(Number) FGL concurrent writes.id
(String) SDS ID.ip_list
(Attributes List) List of IPs associated with SDS. (see below for nested schema)last_upgrade_time
(Number) Last time SDS was upgraded.links
(Attributes List) Specifies the links asscociated with SDS. (see below for nested schema)maintenance_state
(String) Maintenance state.maintenance_type
(String) Maintenance type.mdm_connection_state
(String) MDM connection state.membership_state
(String) Membership state.name
(String) SDS name.num_io_buffers
(Number) Number of IO buffers.num_restarts
(Number) Number of restarts.on_vmware
(Boolean) Presence on VMware.performance_profile
(String) Performance profile.port
(Number) SDS port.raid_controllers
(Attributes List) RAID controllers information. (see below for nested schema)rfcache_enabled
(Boolean) Whether RF cache is enabled or not.rfcache_error_api_version_mismatch
(Boolean) RF cache error for API version mismatch.rfcache_error_device_does_not_exist
(Boolean) RF cache error for device does not exist.rfcache_error_inconsistent_cache_configuration
(Boolean) RF cache error for inconsistent cache configuration.rfcache_error_inconsistent_source_configuration
(Boolean) RF cache error for inconsistent source configuration.rfcache_error_invalid_driver_path
(Boolean) RF cache error for invalid driver path.rfcache_error_low_resources
(Boolean) RF cache error for low resources.rmcache_enabled
(Boolean) Whether RM cache is enabled or not.rmcache_frozen
(Boolean) Indicates whether the Read RAM Cache is currently temporarily not in use.rmcache_memory_allocation_state
(String) Indicates the state of the memory allocation process. Can be one ofin progress
anddone
.rmcache_size
(Number) Indicates the size of Read RAM Cache on the specified SDS in KB.sds_configuration_failure
(Attributes) SDS configuration failure windows. (see below for nested schema)sds_decoupled
(Attributes) SDS decoupled windows. (see below for nested schema)sds_receive_buffer_allocation_failures
(Attributes) SDS receive buffer allocation failure windows. (see below for nested schema)sds_state
(String) SDS state.software_version_info
(String) Software version information.
Nested Schema for sds_details.certificate_info
Read-Only:
issuer
(String) Certificate issuer.subject
(String) Certificate subject.thumbprint
(String) Certificate thumbprint.valid_from
(String) The start date of the certificate validity.valid_from_asn1_format
(String) The start date of the Asn1 format.valid_to
(String) The end date of the certificate validity.valid_to_asn1_format
(String) The end date of the Asn1 format.
Nested Schema for sds_details.ip_list
Read-Only:
ip
(String) SDS IP.role
(String) SDS IP role.
Nested Schema for sds_details.links
Read-Only:
href
(String) Specifies the exact path to fetch the details.rel
(String) Specifies the relationship with the SDS.
Nested Schema for sds_details.raid_controllers
Read-Only:
battery_status
(String) Battery statusdriver_name
(String) Driver name.driver_version
(String) Driver version.firmware_version
(String) Firmware version.model_name
(String) Model name.pci_address
(String) PCI address.serial_number
(String) Serial number.status
(String) RAID status.vendor_name
(String) Vendor name.
Nested Schema for sds_details.sds_configuration_failure
Read-Only:
long_window
(Attributes) Long Window Parameters. (see below for nested schema)medium_window
(Attributes) Medium Window Parameters. (see below for nested schema)short_window
(Attributes) Short Window Parameters. (see below for nested schema)
Nested Schema for sds_details.sds_configuration_failure.long_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_configuration_failure.medium_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_configuration_failure.short_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_decoupled
Read-Only:
long_window
(Attributes) Long Window Parameters. (see below for nested schema)medium_window
(Attributes) Medium Window Parameters. (see below for nested schema)short_window
(Attributes) Short Window Parameters. (see below for nested schema)
Nested Schema for sds_details.sds_decoupled.long_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_decoupled.medium_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_decoupled.short_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_receive_buffer_allocation_failures
Read-Only:
long_window
(Attributes) Long Window Parameters. (see below for nested schema)medium_window
(Attributes) Medium Window Parameters. (see below for nested schema)short_window
(Attributes) Short Window Parameters. (see below for nested schema)
Nested Schema for sds_details.sds_receive_buffer_allocation_failures.long_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_receive_buffer_allocation_failures.medium_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.
Nested Schema for sds_details.sds_receive_buffer_allocation_failures.short_window
Read-Only:
last_oscillation_count
(Number) Last oscillation count.last_oscillation_time
(Number) Last oscillation time.max_failures_count
(Number) Maximum failures count.threshold
(Number) Threshold.window_size_in_sec
(Number) Window Size in seconds.