PowerStore
The CSI Driver for Dell PowerStore can be deployed by using the provided Helm v3 charts and installation scripts on both Kubernetes and OpenShift platforms. For more detailed information on the installation scripts, review the script documentation.
Prerequisites
The following are requirements to be met before installing the CSI Driver for Dell PowerStore:
- A Kubernetes or OpenShift cluster (see supported versions)
- Install Helm 3.x
- If you plan to use either the Fibre Channel, iSCSI, NVMe/TCP, or NVMe/FC protocols, refer to either Fibre Channel requirements or Set up the iSCSI Initiator or Set up the NVMe Initiator sections below. You can use NFS volumes without FC, iSCSI, NVMe/TCP, or NVMe/FC configurations.
You can use either the Fibre Channel (FC), iSCSI, NVMe/TCP, or NVMe/FC protocol, but you do not need all four to be enabled.
For NVMe support the preferred multipath solution is NVMe native multipathing. The Dell Host Connectivity Guide describes the details of each configuration option.
If you want to use pre-configured iSCSI/FC hosts be sure to check that they are not part of any host group.
- Linux native multipathing requirements
- Mount propagation is enabled on container runtime that is being used
- If using Snapshot feature, satisfy all Volume Snapshot requirements
- Insecure registries are defined in Docker or other container runtimes, for CSI drivers that are hosted in a non-secure location
- You can access your cluster with kubectl and helm
- Ensure that your nodes support mounting NFS volumes if using NFS
Install Helm 3.x
Install Helm 3.x on the master node before you install the CSI Driver for Dell PowerStore.
Steps
Run the command to install Helm 3.x.
curl https://raw.githubusercontent.com/helm/helm/master/scripts/get-helm-3 | bash
Fibre Channel requirements
Dell PowerStore supports Fibre Channel connectivity. If you use the Fibre Channel protocol, ensure that the following requirement is met before you install the CSI Driver for Dell PowerStore:
- Zoning of the Host Bus Adapters (HBAs) to the Fibre Channel port must be done.
Set up the iSCSI Initiator
The CSI Driver for Dell PowerStore v1.4 and higher supports iSCSI connectivity.
If you use the iSCSI protocol, set up the iSCSI initiators as follows:
- Ensure that the iSCSI initiators are available on both Controller and Worker nodes.
- Kubernetes nodes must have network connectivity to an iSCSI port on the Dell PowerStore array that has IP interfaces. Manually create IP routes for each node that connects to the Dell PowerStore.
- All Kubernetes nodes must have the iscsi-initiator-utils package for CentOS/RHEL or open-iscsi package for Ubuntu installed, and the iscsid service must be enabled and running.
To do this, run the
systemctl enable --now iscsid
command. - Ensure that the unique initiator name is set in /etc/iscsi/initiatorname.iscsi.
For information about configuring iSCSI, see Dell PowerStore documentation on Dell Support.
Set up the NVMe Initiator
The following requirements must be fulfilled in order to successfully use the NVMe protocols with the CSI PowerStore driver:
- All OpenShift or Kubernetes nodes connecting to Dell storage arrays must use unique NQNs.
- The driver requires the NVMe command-line interface (nvme-cli) to manage the NVMe client and target. The nvme-cli utility provides a command-line and interactive shell option. The NVMe CLI tool is installed in the host using the below command on RPM oriented Linux distributions.
sudo dnf -y install nvme-cli
- Support for NVMe requires native NVMe multipathing to be configured on each worker node in the cluster. Please refer to the Dell Host Connectivity Guide for more details on NVMe connectivity requirements. To determine if the worker nodes are configured for native NVMe multipathing run the following command on each worker node:
cat /sys/module/nvme_core/parameters/multipath
If the result of the command displays Y then NVMe native multipathing is enabled in the kernel. If the output is N then native NVMe multipathing is disabled. Consult the Dell Host Connectivity Guide for Linux to enable native NVMe multipathing.
- The default NVMeTCP native multipathing policy is “numa”. The preferred IO policy for NVMe devices used for PowerStore is round-robin. You can use udev rules to enable the round robin policy on all worker nodes. To view the IO policy you can use the following command:
nvme list-subsys
Configure the IO policy
To change the IO policy to round-robin you can add a udev rule on each worker node. Place a config file in /etc/udev/rules.d with the name 71-nvme-io-policy.rules with the following contents:
ACTION=="add|change", SUBSYSTEM=="nvme-subsystem", ATTR{iopolicy}="round-robin"
In order to change the rules on a running kernel you can run the following commands:
/sbin/udevadm control --reload-rules
/sbin/udevadm trigger --type=devices --action=change
On OCP clusters you can add a MachineConfig to enable this rule on all worker nodes:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-workers-multipath-round-robin
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:text/plain;charset=utf-8;base64,QUNUSU9OPT0iYWRkfGNoYW5nZSIsIFNVQlNZU1RFTT09Im52bWUtc3Vic3lzdGVtIiwgQVRUUntpb3BvbGljeX09InJvdW5kLXJvYmluIg==
verification: {}
filesystem: root
mode: 420
path: /etc/udev/rules.d/71-nvme-io-policy.rules
Configure the control loss timeout
To reduce the impact of PowerStore non disruptive software upgrades you must set the control loss timeout. This can be done using udev rules on each worker node. More information can be found in the Dell Host Connectivity Guide. To configure the control loss timeout place a config file in /etc/udev/rules.d with the name 72-nvmf-ctrl_loss_tmo.rules with the following contents:
ACTION=="add|change", SUBSYSTEM=="nvme", KERNEL=="nvme*", ATTR{ctrl_loss_tmo}="-1"
In order to change the rules on a running kernel you can run the following commands:
/sbin/udevadm control --reload-rules
/sbin/udevadm trigger --type=devices --action=change
On OCP clusters you can add a MachineConfig to enable this rule on all worker nodes:
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-nvmf-ctrl-loss-tmo
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:text/plain;charset=utf-8;base64,QUNUSU9OPT0iYWRkfGNoYW5nZSIsIFNVQlNZU1RFTT09Im52bWUiLCBLRVJORUw9PSJudm1lKiIsIEFUVFJ7Y3RybF9sb3NzX3Rtb309Ii0xIgo=
verification: {}
filesystem: root
mode: 420
path: /etc/udev/rules.d/72-nvmf-ctrl_loss_tmo.rules
Requirements for NVMeTCP
Starting with OCP 4.14 NVMe/TCP is enabled by default on RCOS nodes.
- Modules including the nvme, nvme_core, nvme_fabrics, and nvme_tcp are required for using NVMe over Fabrics using TCP. Load the NVMe and NVMe-OF Modules using the below commands:
modprobe nvme
modprobe nvme_tcp
- The NVMe modules may not be available after a node reboot. Loading the modules at startup is recommended.
Requirements for NVMeFC
- NVMeFC Zoning of the Host Bus Adapters (HBAs) to the Fibre Channel port must be done.
NOTE:
- Do not load the nvme_tcp module for NVMeFC
Linux multipathing requirements
For NVMe connectivity native NVMe multipathing is used. The following sections apply only for iSCSI and Fiber Channel connectivity.
Dell PowerStore supports Linux multipathing and NVMe native multipathing. Configure Linux multipathing before installing the CSI Driver for Dell PowerStore.
Set up Linux multipathing as follows:
- Ensure that all nodes have the Device Mapper Multipathing package installed.
You can install it by running
yum install device-mapper-multipath
on CentOS orapt install multipath-tools
on Ubuntu. This package should create a multipath configuration file located in/etc/multipath.conf
.
- Enable multipathing using the
mpathconf --enable --with_multipathd y
command. - Enable
user_friendly_names
andfind_multipaths
in themultipath.conf
file. - Ensure that the multipath command for
multipath.conf
is available on all Kubernetes nodes.
The following is a sample multipath.conf file:
defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
}
If the above command is not successful, ensure that the /etc/multipath.conf file is present and configured properly. Once the file has been configured correctly, enable the multipath service by running the following command:
sudo systemctl enable multipathd
Finally, you have to restart the service by providing the command
sudo systemctl restart multipathd
On OCP clusters you can add a MachineConfig to configure multipathing on the worker nodes.
You will need to first base64 encode the multipath.conf and add it to the MachineConfig definition.
echo 'defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
}' | base64 -w0
Use the base64 encoded string output in the following MachineConfig
yaml file (under source section)
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: workers-multipath-conf-default
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:text/plain;charset=utf-8;base64,ZGVmYXVsdHMgewp1c2VyX2ZyaWVuZGx5X25hbWVzIHllcwpmaW5kX211bHRpcGF0aHMgeWVzCn0KCmJsYWNrbGlzdCB7Cn0K
verification: {}
filesystem: root
mode: 400
path: /etc/multipath.conf
After deploying thisMachineConfig
object, CoreOS will start the multipath service automatically.
Alternatively, you can check the status of the multipath service by entering the following command in each worker nodes.
sudo multipath -ll
For additional information refer to the Dell Host Connectivity Guide.
(Optional) Volume Snapshot Requirements
For detailed snapshot setup procedure, click here.
Volume Health Monitoring
Volume Health Monitoring feature is optional and by default this feature is disabled for drivers when installed via helm. To enable this feature, add the below block to the driver manifest before installing the driver. This ensures to install external health monitor sidecar. To get the volume health state value under controller should be set to true as seen below. To get the volume stats value under node should be set to true.
controller:
healthMonitor:
# enabled: Enable/Disable health monitor of CSI volumes
# Allowed values:
# true: enable checking of health condition of CSI volumes
# false: disable checking of health condition of CSI volumes
# Default value: None
enabled: false
# interval: Interval of monitoring volume health condition
# Allowed values: Number followed by unit (s,m,h)
# Examples: 60s, 5m, 1h
# Default value: 60s
interval: 60s
node:
healthMonitor:
# enabled: Enable/Disable health monitor of CSI volumes- volume usage, volume condition
# Allowed values:
# true: enable checking of health condition of CSI volumes
# false: disable checking of health condition of CSI volumes
# Default value: None
enabled: false
(Optional) Replication feature Requirements
Applicable only if you decided to enable the Replication feature in values.yaml
replication:
enabled: true
Replication CRD’s
The CRDs for replication can be obtained and installed from the csm-replication project on Github. Use csm-replication/deploy/replicationcrds.all.yaml
located in csm-replication git repo for the installation.
CRDs should be configured during replication prepare stage with repctl as described in install-repctl
Install the Driver
Steps
-
Run
git clone -b v2.10.1 https://github.com/dell/csi-powerstore.git
to clone the git repository. -
Ensure that you have created namespace where you want to install the driver. You can run
kubectl create namespace csi-powerstore
to create a new one. “csi-powerstore” is just an example. You can choose any name for the namespace. But make sure to align to the same namespace during the whole installation. -
Edit
samples/secret/secret.yaml
file and configure connection information for your PowerStore arrays changing following parameters:- endpoint: defines the full URL path to the PowerStore API.
- globalID: specifies what storage cluster the driver should use
- username, password: defines credentials for connecting to array.
- skipCertificateValidation: defines if we should use insecure connection or not.
- isDefault: defines if we should treat the current array as a default.
- blockProtocol: defines what transport protocol we should use (FC, ISCSI, NVMeTCP, NVMeFC, None, or auto).
- nasName: defines what NAS should be used for NFS volumes.
- nfsAcls (Optional): defines permissions - POSIX mode bits or NFSv4 ACLs, to be set on NFS target mount directory. NFSv4 ACls are supported for NFSv4 shares on NFSv4 enabled NAS servers only. POSIX ACLs are not supported and only POSIX mode bits are supported for NFSv3 shares.
Add more blocks similar to above for each PowerStore array if necessary. If replication feature is enabled, ensure the secret includes all the PowerStore arrays involved in replication.
User Privileges
The username specified in
secret.yaml
must be from the authentication providers of PowerStore. The user must have the correct user role to perform the actions. The minimum requirement is Storage Operator. -
Create the secret by running
kubectl create secret generic powerstore-config -n csi-powerstore --from-file=config=secret.yaml
-
Create storage classes using ones from
samples/storageclass
folder as an example and apply them to the Kubernetes cluster by runningkubectl create -f <path_to_storageclass_file>
If you do not specify
arrayID
parameter in the storage class then the array that was specified as the default would be used for provisioning volumes. -
Download the default values.yaml file
cd dell-csi-helm-installer && wget -O my-powerstore-settings.yaml https://github.com/dell/helm-charts/raw/csi-powerstore-2.10.1/charts/csi-powerstore/values.yaml
-
Edit the newly created values file and provide values for the following parameters
vi my-powerstore-settings.yaml
:
Parameter | Description | Required | Default |
---|---|---|---|
images | List all the images used by the CSI driver and CSM. If you use a private repository, change the registries accordingly. | Yes | "" |
logLevel | Defines CSI driver log level | No | “debug” |
logFormat | Defines CSI driver log format | No | “JSON” |
externalAccess | Defines additional entries for hostAccess of NFS volumes, single IP address and subnet are valid entries | No | " " |
kubeletConfigDir | Defines kubelet config path for cluster | Yes | “/var/lib/kubelet” |
maxPowerstoreVolumesPerNode | Defines the default value for maximum number of volumes that the controller can publish to the node. If the value is zero, then CO shall decide how many volumes of this type can be published by the controller to the node. This limit is applicable to all the nodes in the cluster for which the node label ‘max-powerstore-volumes-per-node’ is not set. | No | 0 |
imagePullPolicy | Policy to determine if the image should be pulled prior to starting the container. | Yes | “IfNotPresent” |
nfsAcls | Defines permissions - POSIX mode bits or NFSv4 ACLs, to be set on NFS target mount directory. | No | “0777” |
connection.enableCHAP | Defines whether the driver should use CHAP for iSCSI connections or not | No | False |
controller.controllerCount | Defines number of replicas of controller deployment | Yes | 2 |
controller.volumeNamePrefix | Defines the string added to each volume that the CSI driver creates | No | “csivol” |
controller.snapshot.enabled | Allows to enable/disable snapshotter sidecar with driver installation for snapshot feature | No | “true” |
controller.snapshot.snapNamePrefix | Defines prefix to apply to the names of a created snapshots | No | “csisnap” |
controller.resizer.enabled | Allows to enable/disable resizer sidecar with driver installation for volume expansion feature | No | “true” |
controller.healthMonitor.enabled | Allows to enable/disable volume health monitor | No | false |
controller.healthMonitor.interval | Interval of monitoring volume health condition | No | 60s |
controller.nodeSelector | Defines what nodes would be selected for pods of controller deployment | Yes | " " |
controller.tolerations | Defines tolerations that would be applied to controller deployment | Yes | " " |
node.nodeNamePrefix | Defines the string added to each node that the CSI driver registers | No | “csi-node” |
node.nodeIDPath | Defines a path to file with a unique identifier identifying the node in the Kubernetes cluster | No | “/etc/machine-id” |
node.healthMonitor.enabled | Allows to enable/disable volume health monitor | No | false |
node.nodeSelector | Defines what nodes would be selected for pods of node daemonset | Yes | " " |
node.tolerations | Defines tolerations that would be applied to node daemonset | Yes | " " |
fsGroupPolicy | Defines which FS Group policy mode to be used, Supported modes None, File and ReadWriteOnceWithFSType |
No | “ReadWriteOnceWithFSType” |
controller.vgsnapshot.enabled | Allows to enable/disable the volume group snapshot feature | No | “true” |
version | To use any driver version | No | Latest driver version |
allowAutoRoundOffFilesystemSize | Allows the controller to round off filesystem to 3Gi which is the minimum supported value | No | false |
storageCapacity.enabled | Allows to enable/disable storage capacity tracking feature | No | true |
storageCapacity.pollInterval | Configure how often the driver checks for changed capacity | No | 5m |
podmon.enabled | Allows to enable/disable Resiliency feature | No | false |
- Install the driver using
csi-install.sh
bash script by running./csi-install.sh --namespace csi-powerstore --values ./my-powerstore-settings.yaml --helm-charts-version <version>
- After that the driver should be installed, you can check the condition of driver pods by running
kubectl get all -n csi-powerstore
- After that the driver should be installed, you can check the condition of driver pods by running
NOTE:
- The parameter
--helm-charts-version
is optional and if you do not specify the flag, by default thecsi-install.sh
script will clone the version of the helm chart that is specified in the driver’s csi-install.sh file. If you wish to install the driver using a different version of the helm chart, you need to include this flag. Also, remember to delete thehelm-charts
repository present in thecsi-powerstore
directory if it was cloned before. - For detailed instructions on how to run the install scripts, refer to the readme document in the dell-csi-helm-installer folder.
- By default, the driver scans available SCSI adapters and tries to register them with the storage array under the SCSI hostname using
node.nodeNamePrefix
and the ID read from the file pointed to bynode.nodeIDPath
. If an adapter is already registered with the storage under a different hostname, the adapter is not used by the driver. - A hostname the driver uses for registration of adapters is in the form
<nodeNamePrefix>-<nodeID>-<nodeIP>
. By default, these are csi-node and the machine ID read from the file/etc/machine-id
. - To customize the hostname, for example if you want to make them more user friendly, adjust nodeIDPath and nodeNamePrefix accordingly. For example, you can set
nodeNamePrefix
tok8s
andnodeIDPath
to/etc/hostname
to produce names such ask8s-worker1-192.168.1.2
. - (Optional) Enable additional Mount Options - A user is able to specify additional mount options as needed for the driver.
- Mount options are specified in storageclass yaml under mountOptions.
- WARNING: Before utilizing mount options, you must first be fully aware of the potential impact and understand your environment’s requirements for the specified option.
Storage Classes
The CSI driver for Dell PowerStore version 1.3 and later, dell-csi-helm-installer
does not create any storage classes as part of the driver installation. A wide set of annotated storage class manifests have been provided in the samples/storageclass
folder. Use these samples to create new storage classes to provision storage.
What happens to my existing storage classes?
Upgrading from an older version of the driver: The storage classes will be deleted if you upgrade the driver. If you wish to continue using those storage classes, you can patch them and apply the annotation “helm.sh/resource-policy”: keep before performing an upgrade.
Note: If you continue to use the old storage classes, you may not be able to take advantage of any new storage class parameter supported by the driver.
Steps to create storage class:
There are samples storage class yaml files available under samples/storageclass
. These can be copied and modified as needed.
- Edit the sample storage class yaml file and update following parameters:
- arrayID: specifies what storage cluster the driver should use, if not specified driver will use storage cluster specified as
default
insamples/secret/secret.yaml
- csi.storage.k8s.io/fstype: specifies what filesystem type driver should use, possible variants
ext3
,ext4
,xfs
,nfs
, if not specified driver will useext4
by default. - nfsAcls (Optional): defines permissions - POSIX mode bits or NFSv4 ACLs, to be set on NFS target mount directory.
- allowedTopologies (Optional): If you want you can also add topology constraints.
allowedTopologies: - matchLabelExpressions: - key: csi-powerstore.dellemc.com/12.34.56.78-iscsi # replace "-iscsi" with "-fc", "-nvmetcp" or "-nvmefc" or "-nfs" at the end to use FC, NVMeTCP, NVMeFC or NFS enabled hosts # replace "12.34.56.78" with PowerStore endpoint IP values: - "true"
- Create your storage class by using
kubectl
:kubectl create -f <path_to_storageclass_file>
NOTE: Deleting a storage class has no impact on a running Pod with mounted PVCs. You cannot provision new PVCs until at least one storage class is newly created.
Volume Snapshot Class
Starting CSI PowerStore v1.4.0, dell-csi-helm-installer
will not create any Volume Snapshot Class during the driver installation. There is a sample Volume Snapshot Class manifest present in the samples/volumesnapshotclass folder. Please use this sample to create a new Volume Snapshot Class to create Volume Snapshots.
Dynamically update the powerstore secrets
CSI PowerStore supports the ability to dynamically modify array information within the secret, allowing users to update credentials for the PowerStore arrays, in-flight, without restarting the driver.
Note: Updates to the secret that include adding a new array, or modifying the endpoint, globalID, or blockProtocol parameters require the driver to be restarted to properly pick up and process the changes.
User can update the secret using the following commands:
kubectl create secret generic powerstore-config -n csi-powerstore --from-file=config=secret.yaml -o yaml --dry-run=client | kubectl replace -f -
Dynamic Logging Configuration
This feature is introduced in CSI Driver for PowerStore version 2.0.0.
Helm based installation
As part of driver installation, a ConfigMap with the name powerstore-config-params
is created, which contains attributes CSI_LOG_LEVEL
which specifies the current log level of CSI driver and CSI_LOG_FORMAT
which specifies the current log format of CSI driver.
Users can set the default log level by specifying log level to logLevel
and log format to logFormat
attribute in my-powerstore-settings.yaml
during driver installation.
To change the log level or log format dynamically to a different value user can edit the same values.yaml, and run the following command
cd dell-csi-helm-installer
./csi-install.sh --namespace csi-powerstore --values ./my-powerstore-settings.yaml --upgrade
Note: here my-powerstore-settings.yaml
is a values.yaml
file which user has used for driver installation.
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.